Literature DB >> 18813932

Visualisation of intracerebral haemorrhage with flat-detector CT compared to multislice CT: results in 44 cases.

Tobias Struffert1, Gregor Richter, Tobias Engelhorn, Marc Doelken, Philipp Goelitz, Willi A Kalender, Oliver Ganslandt, Arnd Doerfler.   

Abstract

The aim of the study was to test the reliability of intracerebral haemorrhage (ICH) detection with C-arm-mounted flat-detector computed tomography (FD-CT) in the angio suite as compared to multislice CT (MSCT). In this study 44 patients with 45 ICH were included. All patients were investigated with MSCT and FD-CT during angiographic evaluation. As a control group we included 16 patients without ICH. In each haematoma we assessed volumetric data of the ICH and counted the numbers of ICH-positive slices. Using interobserver ratings, we additionally investigated the potential of FD-CT to serve as a diagnostic tool to detect ICH. In FD-CT three haematomas were not detected because of motion and beam-hardening artefacts in the region close to the skull base. The r value for the degree of interobserver agreement for the number of slices was 0.95 for MSCT and 0.94 for FD-CT. Measurements of the area and the calculated volume of the ICH showed high inter- and intraobserver agreement. Our results indicate that FD-CT is a helpful tool in the daily emergency management of ICH patients as detection of ICH was found to be nearly as reliable as in MSCT. Limitations of this technology are motion and beam-hardening artefacts that may mask small haematomas located in the posterior fossa or the skull base.

Entities:  

Mesh:

Year:  2008        PMID: 18813932     DOI: 10.1007/s00330-008-1183-7

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  13 in total

1.  [The use of flat-panel detectors for CT imaging].

Authors:  W A Kalender
Journal:  Radiologe       Date:  2003-05       Impact factor: 0.635

Review 2.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

3.  Myelography using flat panel volumetric computed tomography: a comparative study in patients with lumbar spinal stenosis.

Authors:  Tobias Engelhorn; Janine Rennert; Gregor Richter; Tobias Struffert; Oliver Ganslandt; Arnd Doerfler
Journal:  Spine (Phila Pa 1976)       Date:  2007-08-15       Impact factor: 3.468

Review 4.  Aneurysmal rupture during coiling: low incidence and good outcomes at a single large volume center.

Authors:  Jonathan L Brisman; Yasunari Niimi; Joon K Song; Alejandro Berenstein
Journal:  Neurosurgery       Date:  2005-12       Impact factor: 4.654

5.  Experimental study of intracranial hematoma detection with flat panel detector C-arm CT.

Authors:  H Arakawa; M P Marks; H M Do; D M Bouley; N Strobel; T Moore; R Fahrig
Journal:  AJNR Am J Neuroradiol       Date:  2008-01-17       Impact factor: 3.825

6.  Flat panel detector angiographic CT for stent-assisted coil embolization of broad-based cerebral aneurysms.

Authors:  G Richter; T Engelhorn; T Struffert; M Doelken; O Ganslandt; J Hornegger; W A Kalender; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2007-09-24       Impact factor: 3.825

7.  The utility of DynaCT in neuroendovascular procedures.

Authors:  N S Heran; J K Song; K Namba; W Smith; Y Niimi; A Berenstein
Journal:  AJNR Am J Neuroradiol       Date:  2006-02       Impact factor: 3.825

Review 8.  Spontaneous intracerebral haemorrhage in adults: a literature overview.

Authors:  D Hänggi; H-J Steiger
Journal:  Acta Neurochir (Wien)       Date:  2008-01-08       Impact factor: 2.216

9.  Severe intracranial bleedings during endovascular procedures: outcome of surgically treated patients.

Authors:  Mario Carvi y Nievas; Eberhard Haas; Hans-Georg Höllerhage
Journal:  Neurol Res       Date:  2007-01       Impact factor: 2.448

Review 10.  Management of intracerebral hemorrhage.

Authors:  Ramandeep Sahni; Jesse Weinberger
Journal:  Vasc Health Risk Manag       Date:  2007
View more
  39 in total

1.  Angiographic CT for intraprocedural monitoring of complex neuroendovascular procedures.

Authors:  J Pfaff; T Struffert; P Gölitz; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2012-04-05       Impact factor: 3.825

Review 2.  [Flat-detector computed tomography in diagnostic and interventional neuroradiology].

Authors:  T Struffert; A Doerfler
Journal:  Radiologe       Date:  2009-09       Impact factor: 0.635

3.  Metal artifact reduction for clipping and coiling in interventional C-arm CT.

Authors:  D Prell; Y Kyriakou; T Struffert; A Dörfler; W A Kalender
Journal:  AJNR Am J Neuroradiol       Date:  2009-11-26       Impact factor: 3.825

Review 4.  C-arm flat detector computed tomography: the technique and its applications in interventional neuro-radiology.

Authors:  Mudassar Kamran; Sanjoy Nagaraja; James V Byrne
Journal:  Neuroradiology       Date:  2009-10-27       Impact factor: 2.804

5.  Artifact reduction of different metallic implants in flat detector C-arm CT.

Authors:  S-C Hung; C-C Wu; C-J Lin; W-Y Guo; C-B Luo; F-C Chang; C-Y Chang
Journal:  AJNR Am J Neuroradiol       Date:  2014-01-23       Impact factor: 3.825

6.  Flat-detector computed tomography in the assessment of intracranial stents: comparison with multi detector CT and conventional angiography in a new animal model.

Authors:  Tobias Struffert; Sabine Ott; Edyta Adamek; Marc Schwarz; Tobias Engelhorn; Stephan Kloska; Yu Deuerling-Zheng; Arnd Doerfler
Journal:  Eur Radiol       Date:  2011-03-02       Impact factor: 5.315

7.  Accuracy of flat panel detector CT with integrated navigational software with and without MR fusion for single-pass needle placement.

Authors:  Marc C Mabray; Sanjit Datta; Prasheel V Lillaney; Teri Moore; Sonja Gehrisch; Jason F Talbott; Michael R Levitt; Basavaraj V Ghodke; Paul S Larson; Daniel L Cooke
Journal:  J Neurointerv Surg       Date:  2015-06-05       Impact factor: 5.836

8.  C-arm flat-panel CT arthrography of the wrist and elbow: first experiences in human cadavers.

Authors:  Roman Guggenberger; Fabian Morsbach; Hatem Alkadhi; Magdalena Vich; Thomas Pfammatter; Juerg Hodler; Gustav Andreisek
Journal:  Skeletal Radiol       Date:  2012-08-29       Impact factor: 2.199

9.  Intraprocedural angiographic CT as a valuable tool in the course of endovascular treatment of direct sinus cavernous fistulas.

Authors:  P Gölitz; T Struffert; M Arc Saake; F Knossalla; A Doerfler
Journal:  Interv Neuroradiol       Date:  2012-09-10       Impact factor: 1.610

10.  C-arm CT measurement of cerebral blood volume in ischemic stroke: an experimental study in canines.

Authors:  T Bley; C M Strother; K Pulfer; K Royalty; M Zellerhoff; Y Deuerling-Zheng; F Bender; D Consigny; R Yasuda; D Niemann
Journal:  AJNR Am J Neuroradiol       Date:  2010-01-06       Impact factor: 3.825

View more