Literature DB >> 29466904

Effect of metal artifact reduction software on image quality of C-arm cone-beam computed tomography during intracranial aneurysm treatment.

Yukiko Enomoto1, Keita Yamauchi1, Takahiko Asano2, Katharina Otani3, Toru Iwama1.   

Abstract

Background and purpose C-arm cone-beam computed tomography (CBCT) has the drawback that image quality is degraded by artifacts caused by implanted metal objects. We evaluated whether metal artifact reduction (MAR) prototype software can improve the subjective image quality of CBCT images of patients with intracranial aneurysms treated with coils or clips. Materials and methods Forty-four patients with intracranial aneurysms implanted with coils (40 patients) or clips (four patients) underwent one CBCT scan from which uncorrected and MAR-corrected CBCT image datasets were reconstructed. Three blinded readers evaluated the image quality of the image sets using a four-point scale (1: Excellent, 2: Good, 3: Poor, 4: Bad). The median scores of the three readers of uncorrected and MAR-corrected images were compared with the paired Wilcoxon signed-rank and inter-reader agreement of change scores was assessed by weighted kappa statistics. The readers also recorded new clinical findings, such as intracranial hemorrhage, air, or surrounding anatomical structures on MAR-corrected images. Results The image quality of MAR-corrected CBCT images was significantly improved compared with the uncorrected CBCT image ( p < 0.001). Additional clinical findings were seen on CBCT images of 70.4% of patients after MAR correction. Conclusion MAR software improved image quality of CBCT images degraded by metal artifacts.

Entities:  

Keywords:  Cone-beam computed tomography; cerebral aneurysm; endovascular treatment

Mesh:

Substances:

Year:  2018        PMID: 29466904      PMCID: PMC5967185          DOI: 10.1177/1591019917754039

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  12 in total

1.  Neurological outcomes following intraprocedural rerupture during coil embolization of ruptured intracranial aneurysms.

Authors:  Christopher J Stapleton; Brian P Walcott; William E Butler; Christopher S Ogilvy
Journal:  J Neurosurg       Date:  2015-01       Impact factor: 5.115

2.  Dose and image quality for a cone-beam C-arm CT system.

Authors:  Rebecca Fahrig; Robert Dixon; Thomas Payne; Richard L Morin; Arundhuti Ganguly; Norbert Strobel
Journal:  Med Phys       Date:  2006-12       Impact factor: 4.071

Review 3.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

4.  Outcomes after aneurysm rupture during endovascular coil embolization.

Authors:  R P Tummala; R M Chu; M T Madison; M Myers; D Tubman; E S Nussbaum
Journal:  Neurosurgery       Date:  2001-11       Impact factor: 4.654

5.  Feasibility of angiographic CT in peri-interventional diagnostic imaging: a comparative study with multidetector CT.

Authors:  M-N Psychogios; J-H Buhk; P Schramm; A Xyda; A Mohr; M Knauth
Journal:  AJNR Am J Neuroradiol       Date:  2010-04-01       Impact factor: 3.825

6.  Rupture of intracranial aneurysms during endovascular coiling: management and outcomes.

Authors:  E Levy; C J Koebbe; M B Horowitz; C A Jungreis; G L Pride; K Dutton; A Kassam; P D Purdy
Journal:  Neurosurgery       Date:  2001-10       Impact factor: 4.654

Review 7.  Cerebral aneurysm perforations complicating therapy with Guglielmi detachable coils: a meta-analysis.

Authors:  Harry J Cloft; David F Kallmes
Journal:  AJNR Am J Neuroradiol       Date:  2002 Nov-Dec       Impact factor: 3.825

8.  Reduction of coil mass artifacts in high-resolution flat detector conebeam CT of cerebral stent-assisted coiling.

Authors:  I M J van der Bom; S Y Hou; A S Puri; G Spilberg; D Ruijters; P van de Haar; B Carelsen; S Vedantham; M J Gounis; A K Wakhloo
Journal:  AJNR Am J Neuroradiol       Date:  2013-05-30       Impact factor: 3.825

9.  Predictors and outcomes of intraprocedural rupture in patients treated for ruptured intracranial aneurysms: the CARAT study.

Authors:  Lucas Elijovich; Randall T Higashida; Michael T Lawton; Gary Duckwiler; Steven Giannotta; S Claiborne Johnston
Journal:  Stroke       Date:  2008-03-06       Impact factor: 7.914

10.  Endovascular treatment of aneurysmal subarachnoid hemorrhage in Japanese Registry of Neuroendovascular Therapy (JR-NET) 1 and 2.

Authors:  Hirotoshi Imamura; Nobuyuki Sakai; Chiaki Sakai; Toshiyuki Fujinaka; Akira Ishii
Journal:  Neurol Med Chir (Tokyo)       Date:  2013-12-27       Impact factor: 1.742

View more
  5 in total

1.  Metal artifact reduction algorithm for image quality improvement of cone-beam CT images of medium or large cerebral aneurysms treated with stent-assisted coil embolization.

Authors:  Satoshi Murai; Masafumi Hiramatsu; Yuji Takasugi; Yu Takahashi; Naoya Kidani; Shingo Nishihiro; Yukei Shinji; Jun Haruma; Tomohito Hishikawa; Kenji Sugiu; Isao Date
Journal:  Neuroradiology       Date:  2019-11-07       Impact factor: 2.804

2.  Are metal artefact reduction algorithms effective to correct cone beam CT artefacts arising from the exomass?

Authors:  Amanda Pelegrin Candemil; Benjamin Salmon; Deborah Queiroz Freitas; Glaucia Maria Bovi Ambrosano; Francisco Haiter-Neto; Matheus Lima Oliveira
Journal:  Dentomaxillofac Radiol       Date:  2019-01-28       Impact factor: 2.419

3.  Clinical Evaluation of an Innovative Metal-Artifact-Reduction Algorithm in FD-CT Angiography in Cerebral Aneurysms Treated by Endovascular Coiling or Surgical Clipping.

Authors:  Felix Eisenhut; Manuel Alexander Schmidt; Alexander Kalik; Tobias Struffert; Julian Feulner; Sven-Martin Schlaffer; Michael Manhart; Arnd Doerfler; Stefan Lang
Journal:  Diagnostics (Basel)       Date:  2022-05-04

4.  Comparison of quantitative measurements of four manufacturer's metal artifact reduction techniques for CT imaging with a self-made acrylic phantom.

Authors:  Ryan Chou; Hung-Yi Chi; Yi-Hung Lin; Liu-Kuo Ying; Yu-Ju Chao; Cheng-Hsun Lin
Journal:  Technol Health Care       Date:  2020       Impact factor: 1.285

5.  In Vitro Quantitative Evaluation of Postprocessing Filter for Metal Artifact Reduction in Cone Beam Computed Tomography Images of Titanium and Zirconium Dioxide Implants.

Authors:  Andre Luiz Ferreira Costa; Karolina A C Fardim; Jennifer M Mantoani; Ana Lucia Franco Ricardo; Maria Aparecida N Jardini; Kaan Orhan; Sérgio Lúcio Pereira de Castro Lopes
Journal:  Biomed Res Int       Date:  2022-02-24       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.