Literature DB >> 17494650

Stent conformity in curved vascular models with simulated aneurysm necks using flat-panel CT: an in vitro study.

N Ebrahimi1, B Claus, C-Y Lee, A Biondi, G Benndorf.   

Abstract

BACKGROUND AND
PURPOSE: Radiographic visibility of self-expandable intracranial stents is insufficient for assessment of conformability and deployment characteristics. The purpose of this study was to evaluate stent mechanics in a curved vessel model by using Flat-Panel CT (FPCT).
MATERIALS AND METHODS: The following stents were used: Neuroform 2, Neuroform Treo, Enterprise, and LEO. All stents were bent in the same polytetrafluoroethylene tubes with various angles ranging from 150 degrees to 30 degrees . To visualize potential prolapse of the stent struts, 4-, 5-, and 8-mm openings were created. FPCTs were obtained using a C-arm with flat detector.
RESULTS: FPCT scans provided excellent visualization of deployment characteristics and stent mechanics and was superior to digital subtraction angiography (DSA) and digital radiography (DR). The Neuroform2/Treo showed, with increasing angle and diameter of the opening, a continuous increase in cell size. These stents also showed an outward prolapse at the convexity and an inwards prolapse of struts at the concavity of the curvature. The Enterprise showed an increasing trend to flatten and to kink with curvatures that are more acute. The LEO showed fewer trends to kink but an inward crimping of its ends with more acute angles.
CONCLUSIONS: Deployment characteristics and conformability to a curved vessel model vary considerably, depending on the angle and the stent design. Adverse mechanics such as increased cell opening, strut prolapse, flattening, and kinking occur during stent placement in a curved vessel model, and may gain clinical importance. FPCT is superior to DSA and DR in visualizing small metallic stents and enables accurate detection of adverse stent mechanics.

Entities:  

Mesh:

Year:  2007        PMID: 17494650      PMCID: PMC8134344     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  18 in total

1.  Reconstruction of the basilar tip with T stent configuration for treatment of a wide-neck aneurysm.

Authors:  Sergin Akpek; Hesham Morsi; Goetz Benndorf; Charles M Strother; Michel E Mawad
Journal:  J Vasc Interv Radiol       Date:  2004-09       Impact factor: 3.464

2.  Conformity of carotid stents with vascular anatomy: evaluation in carotid models.

Authors:  Norimitsu Tanaka; Jean-Baptiste Martin; Koji Tokunaga; Toshi Abe; Yusuke Uchiyama; Naofumi Hayabuchi; Joachim Berkefeld; Daniel A Rüfenacht
Journal:  AJNR Am J Neuroradiol       Date:  2004-04       Impact factor: 3.825

3.  Angiographic CT in cerebrovascular stenting.

Authors:  Götz Benndorf; Charles M Strother; Benjamin Claus; Ramin Naeini; Hesham Morsi; Richard Klucznik; Michael E Mawad
Journal:  AJNR Am J Neuroradiol       Date:  2005-08       Impact factor: 3.825

4.  Treatment of wide-necked cerebral aneurysms with the Neuroform2 Treo stent. A prospective 6-month study.

Authors:  Sepehr Sani; Kirk W Jobe; Demetrius K Lopes
Journal:  Neurosurg Focus       Date:  2005-02-15       Impact factor: 4.047

5.  Initial clinical experience with a new self-expanding nitinol stent for the treatment of intracranial cerebral aneurysms: the Cordis Enterprise stent.

Authors:  Randall T Higashida; Van V Halbach; Christopher F Dowd; Louis Juravsky; Sean Meagher
Journal:  AJNR Am J Neuroradiol       Date:  2005-08       Impact factor: 3.825

6.  Buenos Aires experience with the Neuroform self-expanding stent for the treatment of intracranial aneurysms.

Authors:  Pedro Lylyk; Angel Ferrario; Boris Pasbón; Carlos Miranda; Gustavo Doroszuk
Journal:  J Neurosurg       Date:  2005-02       Impact factor: 5.115

7.  Usefulness of the Neuroform stent for the treatment of cerebral aneurysms: results at initial (3-6-mo) follow-up.

Authors:  David Fiorella; Felipe C Albuquerque; Vivek R Deshmukh; Cameron G McDougall
Journal:  Neurosurgery       Date:  2005-06       Impact factor: 4.654

8.  Preliminary experience using the Neuroform stent for the treatment of cerebral aneurysms.

Authors:  David Fiorella; Felipe C Albuquerque; Patrick Han; Cameron G McDougall
Journal:  Neurosurgery       Date:  2004-01       Impact factor: 4.654

9.  Basilar artery to bilateral posterior cerebral artery 'Y stenting' for endovascular reconstruction of wide-necked basilar apex aneurysms: report of three cases.

Authors:  Eimir Perez-Arjona; Richard D Fessler
Journal:  Neurol Res       Date:  2004-04       Impact factor: 2.448

10.  Retractable self-expandable stent for endovascular treatment of wide-necked intracranial aneurysms: preliminary experience.

Authors:  Boris Lubicz; Xavier Leclerc; Marc Levivier; Jacques Brotchi; Jean-Pierre Pruvo; Jean-Paul Lejeune; Danielle Balériaux
Journal:  Neurosurgery       Date:  2006-03       Impact factor: 4.654

View more
  39 in total

1.  Evaluation of stent visibility by flat panel detector CT in patients treated for intracranial aneurysms.

Authors:  Frédéric Clarençon; Michel Piotin; Silvia Pistocchi; Drazenko Babic; Raphaël Blanc
Journal:  Neuroradiology       Date:  2012-02-04       Impact factor: 2.804

2.  Angiographic CT after intravenous contrast agent application: A noninvasive follow-up tool after intracranial angioplasty and stenting.

Authors:  M-N Psychogios; P Schramm; J-H Buhk; A Xyda; K Gröschel; K Jung; M Knauth
Journal:  AJNR Am J Neuroradiol       Date:  2010-07-15       Impact factor: 3.825

3.  Coil Migration through a Neuroform 3 Stent during Endovascular Coiling. A Case Report.

Authors:  A O'Hare; J Thornton; P Brennan
Journal:  Interv Neuroradiol       Date:  2009-09-01       Impact factor: 1.610

4.  Contrast-enhanced angiographic cone-beam CT of cerebrovascular stents: experimental optimization and clinical application.

Authors:  N V Patel; M J Gounis; A K Wakhloo; N Noordhoek; J Blijd; D Babic; D Takhtani; S-K Lee; A Norbash
Journal:  AJNR Am J Neuroradiol       Date:  2010-10-21       Impact factor: 3.825

Review 5.  Alteration of intra-aneurysmal hemodynamics for flow diversion using enterprise and vision stents.

Authors:  Markus Tremmel; Jianping Xiang; Sabareesh K Natarajan; L Nelson Hopkins; Adnan H Siddiqui; Elad I Levy; Hui Meng
Journal:  World Neurosurg       Date:  2010 Aug-Sep       Impact factor: 2.104

6.  An in vitro study of silk stent morphology.

Authors:  Thaweesak Aurboonyawat; Raphaël Blanc; Paul Schmidt; Michel Piotin; Laurent Spelle; Amir Nakib; Jacques Moret
Journal:  Neuroradiology       Date:  2010-10-28       Impact factor: 2.804

7.  Possible mechanisms for delayed migration of the closed cell--designed enterprise stent when used in the adjunctive treatment of a basilar artery aneurysm.

Authors:  B Gao; A M Malek
Journal:  AJNR Am J Neuroradiol       Date:  2010-09-30       Impact factor: 3.825

8.  Flat-panel versus 64-channel computed tomography for in vivo quantitative characterization of aortic atherosclerotic plaques.

Authors:  Ibrahim Aboshady; Dianna D Cody; Evan M Johnson; Amir Gahremanpour; Deborah Vela; Kamal G Khalil; Herbert L Dupont; James T Willerson; L Maximilian Buja; Gregory W Gladish
Journal:  Int J Cardiol       Date:  2010-12-24       Impact factor: 4.164

9.  Dose reduction in cone-beam CT scanning for intracranial stent deployment before coil embolization of intracranial wide-neck aneurysms.

Authors:  Takumi Kuriyama; Nobuyuki Sakai; Norimitsu Niida; Masaki Sueoka; Mikiya Beppu; Chihebeddine Dahmani; Iwao Kojima; Chiaki Sakai; Hirotoshi Imamura; Katsuhiro Masago; Nobuyuki Katakami
Journal:  Interv Neuroradiol       Date:  2016-02-24       Impact factor: 1.610

10.  Parent vessel size and curvature strongly influence risk of incomplete stent apposition in enterprise intracranial aneurysm stent coiling.

Authors:  R S Heller; A M Malek
Journal:  AJNR Am J Neuroradiol       Date:  2011-08-04       Impact factor: 3.825

View more