Literature DB >> 22492566

Angiographic CT for intraprocedural monitoring of complex neuroendovascular procedures.

J Pfaff1, T Struffert, P Gölitz, A Doerfler.   

Abstract

SUMMARY Evolving techniques in interventional neuroradiology have widened therapeutic options, allowing treatment even in complex cases. Complex neuroendovascular procedures (eg, stent-assisted coiling, stent placement in X- or Y-techniques) require precise delineation of cerebral vasculature and devices. However, because of the complex anatomy or if an ideal projection is not possible, visualization of the parent artery might be difficult. We present 2 complex cases of basilar tip aneurysm in which ACT proved to be beneficial in the intraprocedural monitoring of stent-assisted coil embolization.

Entities:  

Mesh:

Year:  2012        PMID: 22492566      PMCID: PMC8051504          DOI: 10.3174/ajnr.A3014

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  8 in total

1.  Angiographic CT in cerebrovascular stenting.

Authors:  Götz Benndorf; Charles M Strother; Benjamin Claus; Ramin Naeini; Hesham Morsi; Richard Klucznik; Michael E Mawad
Journal:  AJNR Am J Neuroradiol       Date:  2005-08       Impact factor: 3.825

2.  Visualisation of intracerebral haemorrhage with flat-detector CT compared to multislice CT: results in 44 cases.

Authors:  Tobias Struffert; Gregor Richter; Tobias Engelhorn; Marc Doelken; Philipp Goelitz; Willi A Kalender; Oliver Ganslandt; Arnd Doerfler
Journal:  Eur Radiol       Date:  2008-09-24       Impact factor: 5.315

3.  Flat panel detector angiographic CT in the management of aneurysmal rupture during coil embolization.

Authors:  T Engelhorn; T Struffert; G Richter; M Doelken; O Ganslandt; W Kalender; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2008-05-22       Impact factor: 3.825

4.  Y-stent-assisted coil embolization of wide-neck intracranial aneurysms. A single center experience.

Authors:  E Akgul; E Aksungur; T Balli; B Onan; D M Yilmaz; S Bicakci; T Erman
Journal:  Interv Neuroradiol       Date:  2011-04-18       Impact factor: 1.610

5.  X-configured stent-assisted coiling in the endovascular treatment of complex anterior communicating artery aneurysms: a novel reconstructive technique.

Authors:  I Saatci; S Geyik; K Yavuz; S Cekirge
Journal:  AJNR Am J Neuroradiol       Date:  2010-07-01       Impact factor: 3.825

6.  Feasibility of angiographic CT in peri-interventional diagnostic imaging: a comparative study with multidetector CT.

Authors:  M-N Psychogios; J-H Buhk; P Schramm; A Xyda; A Mohr; M Knauth
Journal:  AJNR Am J Neuroradiol       Date:  2010-04-01       Impact factor: 3.825

7.  A novel "Y" stent flow diversion technique for the endovascular treatment of bifurcation aneurysms without endosaccular coiling.

Authors:  H S Cekirge; K Yavuz; S Geyik; I Saatci
Journal:  AJNR Am J Neuroradiol       Date:  2011-04-28       Impact factor: 3.825

8.  Flat panel detector angiographic CT for stent-assisted coil embolization of broad-based cerebral aneurysms.

Authors:  G Richter; T Engelhorn; T Struffert; M Doelken; O Ganslandt; J Hornegger; W A Kalender; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2007-09-24       Impact factor: 3.825

  8 in total
  3 in total

Review 1.  Flat-Panel Computed Tomography (DYNA-CT) in Neuroradiology. From High-Resolution Imaging of Implants to One-Stop-Shopping for Acute Stroke.

Authors:  A Doerfler; P Gölitz; T Engelhorn; S Kloska; T Struffert
Journal:  Clin Neuroradiol       Date:  2015-06-20       Impact factor: 3.649

2.  Angiographic C-arm CT visualization of the Woven EndoBridge cerebral aneurysm embolization device (WEB): first experience in an animal aneurysm model.

Authors:  T Struffert; S Lang; E Adamek; T Engelhorn; C M Strother; A Doerfler
Journal:  Clin Neuroradiol       Date:  2013-05-28       Impact factor: 3.649

3.  Effective dose to patient measurements in flat-detector and multislice computed tomography: a comparison of applications in neuroradiology.

Authors:  Tobias Struffert; Michael Hauer; Rosemarie Banckwitz; Christoph Köhler; Kevin Royalty; Arnd Doerfler
Journal:  Eur Radiol       Date:  2014-04-02       Impact factor: 5.315

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.