Literature DB >> 19277802

CT outperforms radiography for determination of acetabular cup version after THA.

Bernard Ghelman1, Christopher K Kepler, Stephen Lyman, Alejandro González Della Valle.   

Abstract

Precise evaluation of acetabular cup version is necessary for patients with recurrent hip dislocation after THA. We retrospectively studied 42 patients, who underwent THAs, with multiple cross-table lateral radiographs and CT scans to determine whether radiographic or CT measurement of acetabular component version is more accurate. One observer measured cup version on all radiographs. CT scans were interpreted by one observer. Twenty radiographs were measured twice each by two observers to determine intraobserver and interobserver reliability. We implanted cups in four model pelvises using navigation and compared measurements of anteversion made with radiographs and CT scans. Intraclass correlation coefficients (ICC) for anteversion measurements of two observers were 0.9990 and 0.9998, respectively, when comparing measurements of identical radiographs (intraobserver). Paired values for two observers measuring the same radiograph had an ICC of 0.9686 (interobserver) compared with 0.7412 for measurements from serial radiographs of the same component. The ICC comparing radiographic versus CT-based measurements was 0.6981. CT measurements had stronger correlations with navigated values than radiographic measurements. Accuracy of anteversion measurements on cross-table radiographs depends on radiographic technique and patient positioning whereas properly performed CT measurements are independent of patient position.

Entities:  

Mesh:

Year:  2009        PMID: 19277802      PMCID: PMC2866933          DOI: 10.1007/s11999-009-0774-1

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  32 in total

1.  Evaluation of acetabular anteversion following total hip arthroplasty: necessity of proper centring.

Authors:  T G Goergen; D Resnick
Journal:  Br J Radiol       Date:  1975-04       Impact factor: 3.039

2.  Reduced variability of acetabular cup positioning with use of an imageless navigation system.

Authors:  Michael Nogler; Oliver Kessler; Alexandra Prassl; Bill Donnelly; Robert Streicher; John B Sledge; Martin Krismer
Journal:  Clin Orthop Relat Res       Date:  2004-09       Impact factor: 4.176

3.  Acetabular component orientation in intra- and postoperative positions in total hip arthroplasty.

Authors:  Keiko Hayakawa; Yukihide Minoda; Masaharu Aihara; Akira Sakawa; Kenji Ohzono; Koichi Tada
Journal:  Arch Orthop Trauma Surg       Date:  2008-04-22       Impact factor: 3.067

4.  Dislocation and subluxation of the total hip replacement.

Authors:  M A Ritter
Journal:  Clin Orthop Relat Res       Date:  1976 Nov-Dec       Impact factor: 4.176

5.  Anteversion of the acetabular cup. Measurement of angle after total hip replacement.

Authors:  M K Ackland; W B Bourne; H K Uhthoff
Journal:  J Bone Joint Surg Br       Date:  1986-05

6.  Analysis of version in the acetabular cup.

Authors:  H Seradge; K R Nagle; R J Miller
Journal:  Clin Orthop Relat Res       Date:  1982-06       Impact factor: 4.176

7.  Dislocations after total hip-replacement arthroplasties.

Authors:  G E Lewinnek; J L Lewis; R Tarr; C L Compere; J R Zimmerman
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

8.  The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios.

Authors:  D D D'Lima; A G Urquhart; K O Buehler; R H Walker; C W Colwell
Journal:  J Bone Joint Surg Am       Date:  2000-03       Impact factor: 5.284

9.  A new CT method for measuring cup orientation after total hip arthroplasty: a study of 10 patients.

Authors:  Henrik Olivecrona; Lars Weidenhielm; Lotta Olivecrona; Mats O Beckman; André Stark; Marilyn E Noz; Gerald Q Maguire; Michael P Zeleznik; Lars Svensson; Torbjörn Jonson
Journal:  Acta Orthop Scand       Date:  2004-06

10.  Dislocation following total hip replacement.

Authors:  M A Ali Khan; P H Brakenbury; I S Reynolds
Journal:  J Bone Joint Surg Br       Date:  1981
View more
  30 in total

1.  [Principles and new concepts in computer-navigated total hip arthroplasty].

Authors:  T Renkawitz; M Wörner; E Sendtner; M Weber; P Lechler; J Grifka
Journal:  Orthopade       Date:  2011-12       Impact factor: 1.087

2.  Measuring acetabular component version after THA: CT or plain radiograph?

Authors:  Benjamin McArthur; Michael Cross; Christina Geatrakas; David Mayman; Bernard Ghelman
Journal:  Clin Orthop Relat Res       Date:  2012-03-01       Impact factor: 4.176

3.  Accuracy and reliability of different methods to evaluate the acetabular cup version from plain radiographs.

Authors:  Maximilian Haenle; Wolfram Mittelmeier; Rodrigo Barbano; Klaus Wörtler; Roger Scholz; Rainer Bader
Journal:  Surg Radiol Anat       Date:  2010-06-25       Impact factor: 1.246

4.  Anteroposterior Radiographs Are More Accurate than Cross-Table Lateral Radiographs for Acetabular Anteversion Assessment: a Retrospective Cohort Study.

Authors:  Peter K Sculco; Alexander S McLawhorn; Kaitlin M Carroll; Benjamin A McArthur; David J Mayman
Journal:  HSS J       Date:  2015-10-19

5.  Computer assisted determination of acetabular cup orientation using 2D-3D image registration.

Authors:  Guoyan Zheng; Xuan Zhang
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-02-24       Impact factor: 2.924

6.  Assessment of inter- and intra-observer reliability in the determination of radiographic version and inclination of the cup in metal-on-metal hip resurfacing.

Authors:  Aleksi Reito; Timo Puolakka; Antti Paakkala; Jorma Pajamäki
Journal:  Int Orthop       Date:  2011-08-12       Impact factor: 3.075

7.  Cup alignment in total hip arthroplasty using the muscle-sparing modified Watson-Jones approach-comparison between lateral and supine positions.

Authors:  Yuichi Kishimura; Yukihide Minoda; Shigekazu Mizokawa; Ryo Sugama; Yoichi Ohta; Hiroaki Nakamura
Journal:  Int Orthop       Date:  2019-03-06       Impact factor: 3.075

8.  A cadaver study validating CT assessment of acetabular component orientation: the Perth CT hip protocol.

Authors:  Varun Arora; Richard Hannan; Richard Beaver; Timothy Fletcher; Paul Harvie
Journal:  Skeletal Radiol       Date:  2016-11-08       Impact factor: 2.199

9.  Central X-ray beam correction of radiographic acetabular cup measurement after THA: an experimental study.

Authors:  T Schwarz; M Weber; M Wörner; T Renkawitz; J Grifka; B Craiovan
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-10-06       Impact factor: 2.924

10.  Reliability and validity of measuring acetabular component orientation by plain anteroposterior radiographs.

Authors:  Ming Lu; Yi-Xin Zhou; Hui Du; Ji Zhang; Jian Liu
Journal:  Clin Orthop Relat Res       Date:  2013-05-04       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.