Literature DB >> 22095457

[Principles and new concepts in computer-navigated total hip arthroplasty].

T Renkawitz1, M Wörner, E Sendtner, M Weber, P Lechler, J Grifka.   

Abstract

Combined component placement of cup and stem is closely correlated to stability, functionality and wear in total hip replacement (THA). Computer-navigated orthopedic surgery offers a reliable control method for a complex three-dimensional situation. Imageless navigation systems without the need of preoperative or intraoperative image acquisition and exposure to radiation have been proven to increase the accuracy of positioning the acetabular component and measure intraoperative leg length and offset changes precisely. A new development in this field is the noninvasive external femoral reference marker array system in conjunction with an imageless measurement technique. The future generation of imageless navigation systems will switch from simple measurement tasks to an integral part of the surgical process in navigated THA. The aim will be to find an optimized complementary component orientation with improved postoperative functionality and optimized range of motion without impingement.

Entities:  

Mesh:

Year:  2011        PMID: 22095457     DOI: 10.1007/s00132-011-1845-z

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  42 in total

1.  Accuracy of acetabular cup placement in computer-assisted, minimally-invasive THR in a lateral decubitus position.

Authors:  Ernst Sendtner; Tibor Schuster; Michael Wörner; Thomas Kalteis; Joachim Grifka; Tobias Renkawitz
Journal:  Int Orthop       Date:  2010-05-21       Impact factor: 3.075

2.  Pelvic tilt makes acetabular cup navigation inaccurate.

Authors:  Burkhard Lembeck; Otto Mueller; Patrik Reize; Nikolaus Wuelker
Journal:  Acta Orthop       Date:  2005-08       Impact factor: 3.717

3.  Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation?

Authors:  T Kalteis; M Handel; H Bäthis; L Perlick; M Tingart; J Grifka
Journal:  J Bone Joint Surg Br       Date:  2006-02

4.  Accuracy of navigation-assisted acetabular component positioning studied by computed tomography measurements: methods and results.

Authors:  Thomas Ybinger; W Kumpan; H E Hoffart; B Muschalik; W Bullmann; K Zweymüller
Journal:  J Arthroplasty       Date:  2007-09       Impact factor: 4.757

Review 5.  Imaging and navigation measurement of acetabular component position in THA.

Authors:  Zhinian Wan; Aamer Malik; Branislav Jaramaz; Lisa Chao; Lawrence D Dorr
Journal:  Clin Orthop Relat Res       Date:  2008-11-01       Impact factor: 4.176

6.  Leg length and offset measures with a pinless femoral reference array during THA.

Authors:  Tobias Renkawitz; Tibor Schuster; Joachim Grifka; Thomas Kalteis; Ernst Sendtner
Journal:  Clin Orthop Relat Res       Date:  2009-09-19       Impact factor: 4.176

7.  Adjustment of leg length using imageless navigation THA software without a femoral tracker.

Authors:  Shoji Nishio; Shigeo Fukunishi; Tomokazu Fukui; Yuki Fujihara; Shinichi Yoshiya
Journal:  J Orthop Sci       Date:  2011-03-11       Impact factor: 1.601

8.  Dislocations after total hip-replacement arthroplasties.

Authors:  G E Lewinnek; J L Lewis; R Tarr; C L Compere; J R Zimmerman
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

9.  Functional pelvic orientation measured from lateral standing and sitting radiographs.

Authors:  Anthony M DiGioia; Mahmoud A Hafez; Branislav Jaramaz; Timothy J Levison; James E Moody
Journal:  Clin Orthop Relat Res       Date:  2006-12       Impact factor: 4.176

10.  CT outperforms radiography for determination of acetabular cup version after THA.

Authors:  Bernard Ghelman; Christopher K Kepler; Stephen Lyman; Alejandro González Della Valle
Journal:  Clin Orthop Relat Res       Date:  2009-03-10       Impact factor: 4.176

View more
  2 in total

1.  Fluoroscopy and imageless navigation enable an equivalent reconstruction of leg length and global and femoral offset in THA.

Authors:  Markus Weber; Michael Woerner; Robert Springorum; Ernst Sendtner; Alexander Hapfelmeier; Joachim Grifka; Tobias Renkawitz
Journal:  Clin Orthop Relat Res       Date:  2014-06-26       Impact factor: 4.176

2.  Accuracy of Leg Length and Offset Restoration in Femoral Pinless Navigation Compared to Navigation Using a Fixed Pin during Total Hip Arthroplasty.

Authors:  Markus Weber; Max Thieme; Moritz Kaiser; Florian Völlner; Michael Worlicek; Benjamin Craiovan; Joachim Grifka; Tobias Renkawitz
Journal:  Biomed Res Int       Date:  2018-06-25       Impact factor: 3.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.