Literature DB >> 27714567

Central X-ray beam correction of radiographic acetabular cup measurement after THA: an experimental study.

T Schwarz1, M Weber2, M Wörner2, T Renkawitz2, J Grifka2, B Craiovan2.   

Abstract

PURPOSE: Accurate assessment of cup orientation on postoperative radiographs is essential for evaluating outcome after THA. However, accuracy is impeded by the deviation of the central X-ray beam in relation to the cup and the impossibility of measuring retroversion on standard pelvic radiographs.
METHOD: In an experimental trial, we built an artificial cup holder enabling the setting of different angles of anatomical anteversion and inclination. Twelve different cup orientations were investigated by three examiners. After comparing the two methods for radiographic measurement of the cup position developed by Lewinnek and Widmer, we showed how to differentiate between anteversion and retroversion in each cup position by using a second plane. To show the effect of the central beam offset on the cup, we X-rayed a defined cup position using a multidirectional central beam offset. According to Murray's definition of anteversion and inclination, we created a novel corrective procedure to balance measurement errors caused by deviation of the central beam.
RESULTS: Measurement of the 12 different cup positions with the Lewinnek's method yielded a mean deviation of [Formula: see text] (95 % CI 1.3-2.3) from the original cup anteversion. The respective deviation with the Widmer/Liaw's method was [Formula: see text] (95 % CI 2.4-4.0). In each case, retroversion could be differentiated from anteversion with a second radiograph. Because of the multidirectional central beam offset ([Formula: see text] cm) from the acetabular cup in the cup holder ([Formula: see text] anteversion and [Formula: see text] inclination), the mean absolute difference for anteversion was [Formula: see text] (range [Formula: see text] to [Formula: see text] and [Formula: see text] (range [Formula: see text] to [Formula: see text] for inclination. The application of our novel mathematical correction of the central beam offset reduced deviation to a mean difference of [Formula: see text] for anteversion and [Formula: see text] for inclination.
CONCLUSION: This novel calculation for central beam offset correction enables highly accurate measurement of the cup position.

Keywords:  Anteversion; Central beam offset; Cup position; Inclination; Retroversion; THA

Mesh:

Year:  2016        PMID: 27714567     DOI: 10.1007/s11548-016-1489-x

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  31 in total

1.  Misinterpretation of cup anteversion in total hip arthroplasty using planar radiography.

Authors:  Axel Marx; Marius von Knoch; Jörg Pförtner; Matthias Wiese; Guido Saxler
Journal:  Arch Orthop Trauma Surg       Date:  2006-06-21       Impact factor: 3.067

2.  Correction of acetabular cup orientation measurements for X-ray beam offset.

Authors:  Brian Derbyshire
Journal:  Med Eng Phys       Date:  2008-03-21       Impact factor: 2.242

Review 3.  Imaging and navigation measurement of acetabular component position in THA.

Authors:  Zhinian Wan; Aamer Malik; Branislav Jaramaz; Lisa Chao; Lawrence D Dorr
Journal:  Clin Orthop Relat Res       Date:  2008-11-01       Impact factor: 4.176

4.  Estimation of pelvic tilt on anteroposterior X-rays--a comparison of six parameters.

Authors:  M Tannast; S B Murphy; F Langlotz; S E Anderson; K A Siebenrock
Journal:  Skeletal Radiol       Date:  2005-12-20       Impact factor: 2.199

5.  Reliability and validity of measuring acetabular component orientation by plain anteroposterior radiographs.

Authors:  Ming Lu; Yi-Xin Zhou; Hui Du; Ji Zhang; Jian Liu
Journal:  Clin Orthop Relat Res       Date:  2013-05-04       Impact factor: 4.176

6.  Is the acetabular cup orientation after total hip arthroplasty on a two dimension or three dimension model accurate?

Authors:  Benjamin Craiovan; Tobias Renkawitz; Markus Weber; Joachim Grifka; Lutz Nolte; Guoyan Zheng
Journal:  Int Orthop       Date:  2014-04-16       Impact factor: 3.075

7.  The definition and measurement of acetabular orientation.

Authors:  D W Murray
Journal:  J Bone Joint Surg Br       Date:  1993-03

8.  Dislocations after total hip-replacement arthroplasties.

Authors:  G E Lewinnek; J L Lewis; R Tarr; C L Compere; J R Zimmerman
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

9.  Polyethylene wear and acetabular component orientation.

Authors:  Shantanu Patil; Arnie Bergula; Peter C Chen; Clifford W Colwell; Darryl D D'Lima
Journal:  J Bone Joint Surg Am       Date:  2003       Impact factor: 5.284

10.  CT outperforms radiography for determination of acetabular cup version after THA.

Authors:  Bernard Ghelman; Christopher K Kepler; Stephen Lyman; Alejandro González Della Valle
Journal:  Clin Orthop Relat Res       Date:  2009-03-10       Impact factor: 4.176

View more
  7 in total

Review 1.  Radiographic assessment of the cup orientation after total hip arthroplasty: a literature review.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Ann Transl Med       Date:  2020-02

2.  Three-dimensional orientation and location-dependent varying rules of radiographic angles of the acetabular cup.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Int Orthop       Date:  2018-02-17       Impact factor: 3.075

3.  Assessment of pelvic tilt in anteroposterior radiographs by means of tilt ratios.

Authors:  T Schwarz; A Benditz; H-R Springorum; J Matussek; G Heers; M Weber; T Renkawitz; J Grifka; B Craiovan
Journal:  Arch Orthop Trauma Surg       Date:  2018-04-12       Impact factor: 3.067

Review 4.  [Discrepancy between radiographic and true cup position after total hip arthroplasty : Are we interpreting our radiographic quality indicators correctly? Video article].

Authors:  T J Schwarz; M Weber; T Renkawitz; F Greimel; F Leiss; J Grifka; J Schaumburger
Journal:  Orthopade       Date:  2020-03       Impact factor: 1.087

5.  The synergetic effect of pelvic rotation and X-ray offset on radiographic angles of the acetabular cup.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Guo-Fei Sun; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Med Biol Eng Comput       Date:  2019-09-09       Impact factor: 2.602

6.  Lewinnek Safe Zone References are Frequently Misquoted.

Authors:  Aonnicha Burapachaisri; Ameer Elbuluk; Edem Abotsi; Jim Pierrepont; Seth A Jerabek; Aaron J Buckland; Jonathan M Vigdorchik
Journal:  Arthroplast Today       Date:  2020-11-26

7.  Three-dimensional acetabular orientation during periacetabular osteotomy: a video analysis of acetabular rim position using an external fixator as navigation tool during reorientation procedure.

Authors:  Timo J Schwarz; Günther Maderbacher; Franziska Leiss; Joachim Grifka; G Heers; J Matussek
Journal:  Arch Orthop Trauma Surg       Date:  2020-10-24       Impact factor: 3.067

  7 in total