Computer assisted determination of acetabular cup orientation using 2D-3D image registration.

Guoyan Zheng1, Xuan Zhang.   

Abstract

BACKGROUND: 2D-3D image-based registration methods have been developed to measure acetabular cup orientation after total hip arthroplasty (THA). These methods require registration of both the prosthesis and the CT images to 2D radiographs and compute implant position with respect to a reference. The application of these methods is limited in clinical practice due to two limitations: (1) the requirement of a computer-aided design (CAD) model of the prosthesis, which may be unavailable due to the proprietary concerns of the manufacturer, and (2) the requirement of either multiple radiographs or radiograph-specific calibration, usually unavailable for retrospective studies. In this paper, we propose a new method to address these limitations.
METHODS: A new formulation for determination of post-operative cup orientation, which couples a radiographic measurement with 2D-3D image matching, was developed. In our formulation, the radiographic measurement can be obtained with known methods so that the challenge lies in the 2D-3D image matching. To solve this problem, a hybrid 2D-3D registration scheme combining a landmark-to-ray 2D-3D alignment with a robust intensity-based 2D-3D registration was used. The hybrid 2D-3D registration scheme allows computing both the post-operative cup orientation with respect to an anatomical reference and the pelvic tilt and rotation with respect to the X-ray imaging table/plate. The method was validated using 2D adult cadaver hips.
RESULTS: Using the hybrid 2D-3D registration scheme, our method showed a mean accuracy of 1.0 +/- 0.7 degrees (range from 0.1 degrees to 2.0 degrees) for inclination and 1.7 +/- 1.2 degrees (range from 0.0 degrees to 3.9 degrees) for anteversion, taking the measurements from post-operative CT images as ground truths.
CONCLUSIONS: Our new solution formulation and the hybrid 2D-3D registration scheme facilitate estimation of post-operative cup orientation and measurement of pelvic tilt and rotation.

Entities:  

Mesh:

Year:  2010        PMID: 20180034     DOI: 10.1007/s11548-010-0407-x

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  36 in total

1.  Tilt and rotation correction of acetabular version on pelvic radiographs.

Authors:  M Tannast; G Zheng; C Anderegg; K Burckhardt; F Langlotz; R Ganz; K A Siebenrock
Journal:  Clin Orthop Relat Res       Date:  2005-09       Impact factor: 4.176

2.  Pelvic tilt makes acetabular cup navigation inaccurate.

Authors:  Burkhard Lembeck; Otto Mueller; Patrik Reize; Nikolaus Wuelker
Journal:  Acta Orthop       Date:  2005-08       Impact factor: 3.717

3.  Misinterpretation of cup anteversion in total hip arthroplasty using planar radiography.

Authors:  Axel Marx; Marius von Knoch; Jörg Pförtner; Matthias Wiese; Guido Saxler
Journal:  Arch Orthop Trauma Surg       Date:  2006-06-21       Impact factor: 3.067

4.  Radiographic evaluation of the hip has limited reliability.

Authors:  John C Clohisy; John C Carlisle; Robert Trousdale; Young-Jo Kim; Paul E Beaule; Patrick Morgan; Karen Steger-May; Perry L Schoenecker; Michael Millis
Journal:  Clin Orthop Relat Res       Date:  2008-12-02       Impact factor: 4.176

5.  Assessing the accuracy factors in the determination of postoperative acetabular cup orientation using hybrid 2D-3D registration.

Authors:  Guoyan Zheng
Journal:  J Digit Imaging       Date:  2009-07-21       Impact factor: 4.056

6.  Validation of a new method for determination of cup orientation in THA.

Authors:  Simon D Steppacher; Moritz Tannast; Guoyan Zheng; Xuan Zhang; Jens Kowal; Suzanne E Anderson; Klaus A Siebenrock; Stephen B Murphy
Journal:  J Orthop Res       Date:  2009-12       Impact factor: 3.494

7.  Anatomic referencing of cup orientation in total hip arthroplasty.

Authors:  Moritz Tannast; Ulrich Langlotz; Klaus-Arno Siebenrock; Matthias Wiese; Kai Bernsmann; Frank Langlotz
Journal:  Clin Orthop Relat Res       Date:  2005-07       Impact factor: 4.176

8.  The definition and measurement of acetabular orientation.

Authors:  D W Murray
Journal:  J Bone Joint Surg Br       Date:  1993-03

9.  Dislocations after total hip-replacement arthroplasties.

Authors:  G E Lewinnek; J L Lewis; R Tarr; C L Compere; J R Zimmerman
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

10.  Polyethylene wear and acetabular component orientation.

Authors:  Shantanu Patil; Arnie Bergula; Peter C Chen; Clifford W Colwell; Darryl D D'Lima
Journal:  J Bone Joint Surg Am       Date:  2003       Impact factor: 5.284

View more
  3 in total

1.  Is the acetabular cup orientation after total hip arthroplasty on a two dimension or three dimension model accurate?

Authors:  Benjamin Craiovan; Tobias Renkawitz; Markus Weber; Joachim Grifka; Lutz Nolte; Guoyan Zheng
Journal:  Int Orthop       Date:  2014-04-16       Impact factor: 3.075

2.  Validation of a statistical shape model-based 2D/3D reconstruction method for determination of cup orientation after THA.

Authors:  G Zheng; J von Recum; L-P Nolte; P A Grützner; S D Steppacher; J Franke
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-07-27       Impact factor: 2.924

3.  Association of Femoral Rotation With Whole-Body Alignment in Patients Who Underwent Total Hip Arthroplasty.

Authors:  Daigo Kobayashi; Hyonmin Choe; Naomi Kobayashi; Taro Tezuka; Hiroyuki Ike; Yutaka Inaba
Journal:  Arthroplast Today       Date:  2020-07-23
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.