Literature DB >> 15346068

Reduced variability of acetabular cup positioning with use of an imageless navigation system.

Michael Nogler1, Oliver Kessler, Alexandra Prassl, Bill Donnelly, Robert Streicher, John B Sledge, Martin Krismer.   

Abstract

Positioning the acetabular component is one of the most important steps in total hip arthroplasty; malpositioned components can result in dislocations, impingement, limited range of motion, and increased polyethylene wear. Conventional surgery makes use of specialized alignment guides provided by the manufacturers of the implants. The use of mechanical guides has been shown to result in large variations of cup inclination and version. We investigated acetabular cup alignment with the nonimage-based hip navigation system compared with a conventional mechanically guided procedure in 12 human cadavers. Postoperative cup position relative to the pelvic reference plane was assessed in both groups with the use of a three-dimensional digitizing arm. In the navigated group, a median inclination of 45.5 degrees and a median anteversion of 21.9 degrees (goals, 45 degrees and 20 degrees) were reached. In the control group, the median inclination was 41.8 degrees and the median anteversion was 24.6 degrees. The ninetieth percentile showed a much wider range for the control group (36.1 degrees-51.8 degrees inclination, 15 degrees-33.5 degrees anteversion) than for the navigated group (43.9 degrees-48.2 degrees inclination, 18.3 degrees-25.4 degrees anteversion). This cadaver study shows that computer-assisted cup positioning using a nonimage-based hip navigation system allowed for more consistent placement of the acetabular component.

Entities:  

Mesh:

Year:  2004        PMID: 15346068     DOI: 10.1097/01.blo.0000141902.30946.6d

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  30 in total

1.  Improving cup positioning using a mechanical navigation instrument.

Authors:  Simon D Steppacher; Jens H Kowal; Stephen Barry Murphy
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

2.  Accuracy of acetabular cup placement in computer-assisted, minimally-invasive THR in a lateral decubitus position.

Authors:  Ernst Sendtner; Tibor Schuster; Michael Wörner; Thomas Kalteis; Joachim Grifka; Tobias Renkawitz
Journal:  Int Orthop       Date:  2010-05-21       Impact factor: 3.075

3.  Acetabular component positioning using anatomic landmarks of the acetabulum.

Authors:  Yong-Chan Ha; Jeong Joon Yoo; Young-Kyun Lee; Jin Young Kim; Kyung-Hoi Koo
Journal:  Clin Orthop Relat Res       Date:  2012-07-10       Impact factor: 4.176

4.  A cost-effective surgical navigation solution for periacetabular osteotomy (PAO) surgery.

Authors:  Silvio Pflugi; Li Liu; Timo M Ecker; Steffen Schumann; Jennifer Larissa Cullmann; Klaus Siebenrock; Guoyan Zheng
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-08-02       Impact factor: 2.924

5.  Anteroposterior Radiographs Are More Accurate than Cross-Table Lateral Radiographs for Acetabular Anteversion Assessment: a Retrospective Cohort Study.

Authors:  Peter K Sculco; Alexander S McLawhorn; Kaitlin M Carroll; Benjamin A McArthur; David J Mayman
Journal:  HSS J       Date:  2015-10-19

6.  Development of imageless computer navigation for acetabular component position in total hip replacement.

Authors:  Lawrence D Dorr; Yuji Hishiki; Zhinian Wan; Deanne Newton; Andrew Yun
Journal:  Iowa Orthop J       Date:  2005

7.  Greater accuracy in positioning of the acetabular cup by using an image-free navigation system.

Authors:  T Kalteis; M Handel; T Herold; L Perlick; H Baethis; J Grifka
Journal:  Int Orthop       Date:  2005-08-05       Impact factor: 3.075

Review 8.  [Precision in orthopaedic computer navigation].

Authors:  T Hüfner; D Kendoff; M Citak; J Geerling; C Krettek
Journal:  Orthopade       Date:  2006-10       Impact factor: 1.087

9.  Six sigma analysis of minimally invasive acetabular arthroplasty: a preliminary investigation.

Authors:  David A Heck; James B Stiehl
Journal:  Clin Orthop Relat Res       Date:  2009-05-22       Impact factor: 4.176

10.  Does computer-assisted surgery benefit leg length restoration in total hip replacement? Navigation versus conventional freehand.

Authors:  Alfonso Manzotti; Pietro Cerveri; Elena De Momi; Chris Pullen; Norberto Confalonieri
Journal:  Int Orthop       Date:  2009-11-11       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.