Reliability and validity of measuring acetabular component orientation by plain anteroposterior radiographs.

Ming Lu1, Yi-Xin Zhou, Hui Du, Ji Zhang, Jian Liu.   

Abstract

BACKGROUND: Inaccurate placement of an acetabular cup can cause impingement, dislocation, and accelerated wear. However, there is no universally agreed-on approach to measuring cup position using plain radiographs. OBJECTIVES/PURPOSES: Our goal was to evaluate the reliability and validity of measuring the orientation of acetabular components on plain anteroposterior (AP) radiographs.
METHODS: We obtained plain AP radiographs and CT scans for 60 patients who underwent 60 primary total hip arthroplasties (THAs). The method devised by Lewinnek et al. was used to measure the orientation of acetabular components on plain AP radiographs, and three-dimensional (3-D) CT scans were used to measure both the radiographic anteversion angle and the inclination angle. Reliability was evaluated by analysis of the agreement between inter- and intraobserver measurements using plain AP radiographs. Measurements on 3-D CT scans were regarded as the reference standard; validity was assessed by comparing radiographic measurements with the CT scans.
RESULTS: Inter- and intraobserver reliability for measuring component orientation on plain AP radiographs was nearly perfect with intraclass correlation coefficients of 0.896 and 0.969 for anteversion and 0.984 and 0.993 for inclination. Measurement of cup inclination angles differed between plain radiographs and CT scans, but the difference was small, and the difference, although statistically significant, probably was not clinically important (2.3° ± 1.8°, p < 0.001). There was no significant difference between the anteversion as measured on CT scan versus that measured on plain radiographs (p = 0.19).
CONCLUSIONS: Measurement of the orientation of acetabular components on plain AP radiographs is reliable and accurate compared with measurement on CT.

Entities:  

Mesh:

Year:  2013        PMID: 23645336      PMCID: PMC3734435          DOI: 10.1007/s11999-013-3021-8

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  30 in total

1.  3D CT analysis of combined cup and stem anteversion in cases of cup navigation in hip arthroplasty.

Authors:  Georgi I Wassilew; Carsten Perka; Christian Koenig; Viktor Janz; Patrick Asbach; Olaf Hasart
Journal:  Orthopedics       Date:  2010-10       Impact factor: 1.390

2.  Misinterpretation of cup anteversion in total hip arthroplasty using planar radiography.

Authors:  Axel Marx; Marius von Knoch; Jörg Pförtner; Matthias Wiese; Guido Saxler
Journal:  Arch Orthop Trauma Surg       Date:  2006-06-21       Impact factor: 3.067

3.  A new tool for measuring cup orientation in total hip arthroplasties from plain radiographs.

Authors:  Chen-Kun Liaw; Sheng-Mou Hou; Rong-Sen Yang; Tai-Yin Wu; Chiou-Shann Fuh
Journal:  Clin Orthop Relat Res       Date:  2006-10       Impact factor: 4.176

Review 4.  Imaging and navigation measurement of acetabular component position in THA.

Authors:  Zhinian Wan; Aamer Malik; Branislav Jaramaz; Lisa Chao; Lawrence D Dorr
Journal:  Clin Orthop Relat Res       Date:  2008-11-01       Impact factor: 4.176

5.  Validation of a computer navigation system and a CT method for determination of the orientation of implanted acetabular cup in total hip arthroplasty: a cadaver study.

Authors:  Fang Lin; Dohyung Lim; Richard L Wixson; Steven Milos; Ronald W Hendrix; Mohsen Makhsous
Journal:  Clin Biomech (Bristol, Avon)       Date:  2008-06-09       Impact factor: 2.063

6.  Validation of a new method for determination of cup orientation in THA.

Authors:  Simon D Steppacher; Moritz Tannast; Guoyan Zheng; Xuan Zhang; Jens Kowal; Suzanne E Anderson; Klaus A Siebenrock; Stephen B Murphy
Journal:  J Orthop Res       Date:  2009-12       Impact factor: 3.494

7.  A validation model for measurement of acetabular component position.

Authors:  Aamer Malik; Zhinian Wan; Branislav Jaramaz; Gary Bowman; Lawrence D Dorr
Journal:  J Arthroplasty       Date:  2009-06-24       Impact factor: 4.757

8.  A reliability study of measurement tools available on standard picture archiving and communication system workstations for the evaluation of hip radiographs following arthroplasty.

Authors:  Sanjay R Patel; Andoni P Toms; Javed M Rehman; James Wimhurst
Journal:  J Bone Joint Surg Am       Date:  2011-09-21       Impact factor: 5.284

9.  CT outperforms radiography for determination of acetabular cup version after THA.

Authors:  Bernard Ghelman; Christopher K Kepler; Stephen Lyman; Alejandro González Della Valle
Journal:  Clin Orthop Relat Res       Date:  2009-03-10       Impact factor: 4.176

10.  The rationale for tilt-adjusted acetabular cup navigation.

Authors:  Jürgen W Babisch; Frank Layher; Louis-Philippe Amiot
Journal:  J Bone Joint Surg Am       Date:  2008-02       Impact factor: 5.284

View more
  38 in total

1.  Anteroposterior Radiographs Are More Accurate than Cross-Table Lateral Radiographs for Acetabular Anteversion Assessment: a Retrospective Cohort Study.

Authors:  Peter K Sculco; Alexander S McLawhorn; Kaitlin M Carroll; Benjamin A McArthur; David J Mayman
Journal:  HSS J       Date:  2015-10-19

2.  Central X-ray beam correction of radiographic acetabular cup measurement after THA: an experimental study.

Authors:  T Schwarz; M Weber; M Wörner; T Renkawitz; J Grifka; B Craiovan
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-10-06       Impact factor: 2.924

3.  Can a simple iPad app improve C-arm based component position in anterior THA?

Authors:  Ulrich Bechler; Bernhard Springer; Kilian Rueckl; Tim Rolvien; Friedrich Boettner
Journal:  Arch Orthop Trauma Surg       Date:  2021-02-13       Impact factor: 3.067

4.  Analysis of acetabular orientation and femoral anteversion using images of three-dimensional reconstructed bone models.

Authors:  Jaeyeong Park; Jun-Young Kim; Hyun Deok Kim; Young Cheol Kim; Anna Seo; Minkyu Je; Jong Uk Mun; Bia Kim; Il Hyung Park; Shin-Yoon Kim
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-01-06       Impact factor: 2.924

5.  [Measurement of acetabular cup inclination in anteroposterior pelvic radiogram : An indicator of quality after primary total hip arthroplasty?]

Authors:  T Loitsch; T Freitag; F Leucht; H Reichel; R Bieger
Journal:  Orthopade       Date:  2018-12       Impact factor: 1.087

6.  Does stem design influence component positioning in total hip arthroplasty using a minimal invasive posterolateral approach?

Authors:  Wenzel Waldstein; Christian Merle; Tom Schmidt-Braekling; Friedrich Boettner
Journal:  Int Orthop       Date:  2014-03-07       Impact factor: 3.075

7.  Is the acetabular cup orientation after total hip arthroplasty on a two dimension or three dimension model accurate?

Authors:  Benjamin Craiovan; Tobias Renkawitz; Markus Weber; Joachim Grifka; Lutz Nolte; Guoyan Zheng
Journal:  Int Orthop       Date:  2014-04-16       Impact factor: 3.075

8.  The Müller self-locking cemented total hip prosthesis with polyethylene liner: After twenty years, what did they become?

Authors:  Roger Erivan; Guillaume Villatte; Youcef Reda Khelif; Bruno Pereira; Myriam Galvin; Stéphane Descamps; Stéphane Boisgard
Journal:  Int Orthop       Date:  2016-04-25       Impact factor: 3.075

9.  Accuracy of measuring acetabular cup position after total hip arthroplasty: comparison between a radiographic planning software and three-dimensional computed tomography.

Authors:  Vahdettin Bayraktar; Markus Weber; Frederik von Kunow; Florian Zeman; Benjamin Craiovan; Tobias Renkawitz; Joachim Grifka; Michael Woerner
Journal:  Int Orthop       Date:  2016-06-08       Impact factor: 3.075

10.  Cross table lateral radiography for measurement of acetabular cup version.

Authors:  Olav Reikeras; Ragnhild Beate Gunderson
Journal:  Ann Transl Med       Date:  2016-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.