Literature DB >> 641088

Dislocations after total hip-replacement arthroplasties.

G E Lewinnek, J L Lewis, R Tarr, C L Compere, J R Zimmerman.   

Abstract

In a series of 300 total hip replacements, nine (3 per cent) dislocated. Precise measurements of the orientation of the acetabular cup were made and it was found that anterior dislocations were associated with increased acetabular-component anteversion. There was no significant correlation between cup-orientation angle and posterior dislocation. The dislocation rate for cup orientation with anteversion of 15 +/- 10 degrees and lateral opening of 40 +/- 10 degrees was 1.5 per cent, while outside this "safe" range the dislocation rate was 6.1 per cent. Other factors that were documented include time after surgery (with the greatest risk in the first thirty days) and surgical history (with a greater risk in hips that have had prior surgery).

Mesh:

Year:  1978        PMID: 641088

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  555 in total

1.  Hip-spine relationship: a radio-anatomical study for optimization in acetabular cup positioning.

Authors:  J-Y Lazennec; N Charlot; M Gorin; B Roger; N Arafati; A Bissery; G Saillant
Journal:  Surg Radiol Anat       Date:  2003-11-07       Impact factor: 1.246

2.  [CT-free image guided acetabulum navigation in clinical routine].

Authors:  J Von Recum; K Wendl; J Korber; A Wentzensen; P A Grützner
Journal:  Unfallchirurg       Date:  2003-11       Impact factor: 1.000

3.  Differences between the wear couples metal-on-polyethylene and ceramic-on-ceramic in the stability against dislocation of total hip replacement.

Authors:  Rainer Bader; Erwin Steinhauser; Susanne Zimmermann; Wolfram Mittelmeier; Roger Scholz; Raymonde Busch
Journal:  J Mater Sci Mater Med       Date:  2004-06       Impact factor: 3.896

4.  [Principles and new concepts in computer-navigated total hip arthroplasty].

Authors:  T Renkawitz; M Wörner; E Sendtner; M Weber; P Lechler; J Grifka
Journal:  Orthopade       Date:  2011-12       Impact factor: 1.087

5.  Study of the three-dimensional orientation of the labrum: its relations with the osseous acetabular rim.

Authors:  Noémie Bonneau; July Bouhallier; Michel Baylac; Christine Tardieu; Olivier Gagey
Journal:  J Anat       Date:  2012-02-23       Impact factor: 2.610

6.  Measuring acetabular component version after THA: CT or plain radiograph?

Authors:  Benjamin McArthur; Michael Cross; Christina Geatrakas; David Mayman; Bernard Ghelman
Journal:  Clin Orthop Relat Res       Date:  2012-03-01       Impact factor: 4.176

7.  Intra- and extra-articular planes of reference for use in total hip arthroplasty: a preliminary study.

Authors:  Jerome Hausselle; Pierre Etienne Moreau; Loic Wessely; Emmanuel de Thomasson; Ayman Assi; Sebastien Parratte; Jerome Essig; Wafa Skalli
Journal:  Int Orthop       Date:  2012-03-21       Impact factor: 3.075

8.  A new method of measuring acetabular cup anteversion on simulated radiographs.

Authors:  Vikas Bachhal; Nipun Jindal; Gaurav Saini; Radheshyam Sament; Vishal Kumar; Devendra Chouhan; Mandeep Dhillon
Journal:  Int Orthop       Date:  2012-05-31       Impact factor: 3.075

9.  Improving cup positioning using a mechanical navigation instrument.

Authors:  Simon D Steppacher; Jens H Kowal; Stephen Barry Murphy
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

10.  Accuracy of acetabular cup placement in computer-assisted, minimally-invasive THR in a lateral decubitus position.

Authors:  Ernst Sendtner; Tibor Schuster; Michael Wörner; Thomas Kalteis; Joachim Grifka; Tobias Renkawitz
Journal:  Int Orthop       Date:  2010-05-21       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.