Literature DB >> 19214506

Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty.

Jiri Gallo1, Vitezslav Havranek, Jana Zapletalova.   

Abstract

We analysed data from 155 revisions of identical cementless hip prostheses to determine the influence of patient-, implant- and surgery-related factors on the polyethylene wear rate and size of periprosthetic osteolysis (OL). This was calculated by logistic regression analysis. Factors associated with an increased/decreased wear rate included position of the cup relative to Kohler's line, increase in abduction angle of the cup, traumatic and inflammatory arthritis as a primary diagnosis, and patient height. Severe acetabular bone defects were predicted by an increased wear rate (odds ratio, OR = 5.782 for wear rate above 200 mm(3)/y), and increased height of the patient (OR = 0.905 per each centimetre). Predictors of severe bone defects in the femur were the increased wear rate (OR = 3.479 for wear rate above 200 mm(3)/y) and placement of the cup outside of the true acetabulum (OR = 3.292). Variables related to surgical technique were the most predictive of polyethylene wear rate.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19214506      PMCID: PMC2899268          DOI: 10.1007/s00264-009-0731-3

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  45 in total

1.  Comparison of the biological activity of grade GUR 1120 and GUR 415HP UHMWPE wear debris.

Authors:  Joanne Ingram; Jane Bridget Matthews; Joanne Tipper; Martin Stone; John Fisher; Eileen Ingham
Journal:  Biomed Mater Eng       Date:  2002       Impact factor: 1.300

2.  The influence of acetabular cup angle on the wear of "BIOLOX Forte" alumina ceramic bearing couples in a hip joint simulator.

Authors:  J E Nevelos; E Ingham; C Doyle; A B Nevelos; J Fisher
Journal:  J Mater Sci Mater Med       Date:  2001-02       Impact factor: 3.896

3.  Comparison of Bayesian model averaging and stepwise methods for model selection in logistic regression.

Authors:  Duolao Wang; Wenyang Zhang; Ameet Bakhai
Journal:  Stat Med       Date:  2004-11-30       Impact factor: 2.373

4.  Wear analysis of failed acetabular polyethylene: a comparison of analytical methods.

Authors:  G S J Chuter; D J Cloke; A Mahomed; P F Partington; S M Green
Journal:  J Bone Joint Surg Br       Date:  2007-02

5.  Eleven-year results of the ABG I hip replacement.

Authors:  W Y Kim; B N Muddu
Journal:  Int Orthop       Date:  2006-03-07       Impact factor: 3.075

6.  Effect of femoral component offset on polyethylene wear in total hip arthroplasty.

Authors:  D P Sakalkale; P F Sharkey; K Eng; W J Hozack; R H Rothman
Journal:  Clin Orthop Relat Res       Date:  2001-07       Impact factor: 4.176

7.  The John Charnley Award. Wear is a function of use, not time.

Authors:  T P Schmalzried; E F Shepherd; F J Dorey; W O Jackson; M dela Rosa; F Fa'vae; H A McKellop; C D McClung; J Martell; J R Moreland; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  2000-12       Impact factor: 4.176

8.  The pros and cons of polyethylene sterilization with gamma irradiation.

Authors:  Robert H Hopper; C Anderson Engh; LaTonya B Fowlkes; Charles A Engh
Journal:  Clin Orthop Relat Res       Date:  2004-12       Impact factor: 4.176

9.  Polyethylene wear and acetabular component orientation.

Authors:  Shantanu Patil; Arnie Bergula; Peter C Chen; Clifford W Colwell; Darryl D D'Lima
Journal:  J Bone Joint Surg Am       Date:  2003       Impact factor: 5.284

10.  Is the wear factor in total joint replacements dependent on the nominal contact stress in ultra-high molecular weight polyethylene contacts?

Authors:  K Vassiliou; A Unsworth
Journal:  Proc Inst Mech Eng H       Date:  2004       Impact factor: 1.617

View more
  23 in total

1.  The incidence of acetabular osteolysis in young patients with conventional versus highly crosslinked polyethylene.

Authors:  Nathan A Mall; Ryan M Nunley; Jin Jun Zhu; William J Maloney; Robert L Barrack; John C Clohisy
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

2.  The association between the sagittal femoral stem alignment and the resulting femoral head centre in total hip arthroplasty.

Authors:  Michael Müller; Dirk Crucius; Carsten Perka; Stephan Tohtz
Journal:  Int Orthop       Date:  2010-06-13       Impact factor: 3.075

3.  Influence of cup-center-edge angle on micro-motion at the interface between the cup and host bone in cementless total hip arthroplasty: three-dimensional finite element analysis.

Authors:  Nobuhiro Kaku; Tomonori Tabata; Hiroshi Tsumura
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-08-29

4.  Comparison of robotic-assisted and conventional acetabular cup placement in THA: a matched-pair controlled study.

Authors:  Benjamin G Domb; Youssef F El Bitar; Adam Y Sadik; Christine E Stake; Itamar B Botser
Journal:  Clin Orthop Relat Res       Date:  2013-08-29       Impact factor: 4.176

5.  The mechanical effects of cup inclination and anteversion angle on the bearing surface.

Authors:  Nobuhiro Kaku; Tomonori Tabata; Hiroaki Tagomori; Tetsutaro Abe; Hiroshi Tsumura
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-08-05

Review 6.  Vitamin E diffused, highly crosslinked UHMWPE: a review.

Authors:  Ebru Oral; Orhun K Muratoglu
Journal:  Int Orthop       Date:  2010-12-01       Impact factor: 3.075

7.  Pelvic tilt in patients undergoing total hip arthroplasty: when does it matter?

Authors:  Joseph D Maratt; Christina I Esposito; Alexander S McLawhorn; Seth A Jerabek; Douglas E Padgett; David J Mayman
Journal:  J Arthroplasty       Date:  2014-10-23       Impact factor: 4.757

8.  Long-term survival of the uncemented Balgrist total hip replacement cup.

Authors:  Jiri Gallo; Jiri Lostak; Katerina Langova
Journal:  Int Orthop       Date:  2013-06-08       Impact factor: 3.075

9.  Delay of total hip arthroplasty to advanced stage worsens post-operative hip motion in patients with femoral head osteonecrosis.

Authors:  Woo-Lam Jo; Young-Kyun Lee; Yong-Chan Ha; Tae-Young Kim; Kyung-Hoi Koo
Journal:  Int Orthop       Date:  2018-04-26       Impact factor: 3.075

10.  Male gender, Charnley class C, and severity of bone defects predict the risk for aseptic loosening in the cup of ABG I hip arthroplasty.

Authors:  Jiri Gallo; Vitezslav Havranek; Jana Zapletalova; Jiri Lostak
Journal:  BMC Musculoskelet Disord       Date:  2010-10-19       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.