Literature DB >> 26319002

Influence of cup-center-edge angle on micro-motion at the interface between the cup and host bone in cementless total hip arthroplasty: three-dimensional finite element analysis.

Nobuhiro Kaku1, Tomonori Tabata2, Hiroshi Tsumura2.   

Abstract

We verified the index cup position required for bulk bone grafting instead of morcellized grafting immediately after cementless total hip arthroplasty. Three-dimensional finite element analysis was used to evaluate changes in the volume of the slippage of the cup-host bone interface as micro-motion of the cup at the acetabular bone defect site depending on the cup-center-edge (CE) angle. The conditions of bulk bone grafts were similar to those of cortical bone. Slippage increased with decreasing cup-CE angle. A bulk bone graft tightly fixed to the host bone prevented considerably larger slippage between the cup and host bone. A smaller cup-CE angle increased the impact of the bulk bone graft on slippage. When the cup-CE angle was 0° or -10°, the criterion for slippage in favorable initial fixation in all conditions was <40 μm. Even if transplanted bulk bone is used, unless good fixation is obtained between the host bone, and the cup and bone graft, it is impossible to obtain reliable fixation of the cup with a cup-CE angle <-10° and slippage exceeding 40 μm. Bulk bone grafting tightly fixed to the host bone improves initial the cup-host bone fixation, especially when the cup-CE angle is small, such as <-10°. In clinical practice, negative factors are implicated in the initial fixation of various cups, and sufficient fixation between the host bone and cup or bulk bone graft using a screw is effective when the cup-CE angle is extremely small.

Entities:  

Keywords:  Bone graft; Cementless; Cup-center-edge angle; Dysplasia; Finite element model; Micro-motion

Mesh:

Year:  2015        PMID: 26319002     DOI: 10.1007/s00590-015-1697-z

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  30 in total

1.  Quantification of implant micromotion, strain shielding, and bone resorption with porous-coated anatomic medullary locking femoral prostheses.

Authors:  C A Engh; D O'Connor; M Jasty; T F McGovern; J D Bobyn; W H Harris
Journal:  Clin Orthop Relat Res       Date:  1992-12       Impact factor: 4.176

2.  Effect of cementless acetabular component orientation, position, and containment in total hip arthroplasty for congenital hip disease.

Authors:  George Georgiades; George C Babis; Georgia Kourlaba; George Hartofilakidis
Journal:  J Arthroplasty       Date:  2010-03-23       Impact factor: 4.757

3.  Finite element modelling of the pelvis: inclusion of muscular and ligamentous boundary conditions.

Authors:  A T M Phillips; P Pankaj; C R Howie; A S Usmani; A H R W Simpson
Journal:  Med Eng Phys       Date:  2006-10-10       Impact factor: 2.242

4.  How superior placement of the joint center in hip arthroplasty affects the abductor muscles.

Authors:  S L Delp; R L Wixson; A V Komattu; J H Kocmond
Journal:  Clin Orthop Relat Res       Date:  1996-07       Impact factor: 4.176

5.  In vivo skeletal responses to porous-surfaced implants subjected to small induced motions.

Authors:  M Jasty; C Bragdon; D Burke; D O'Connor; J Lowenstein; W H Harris
Journal:  J Bone Joint Surg Am       Date:  1997-05       Impact factor: 5.284

6.  Limitation of total hip arthroplasty of the acetabular roof by press-fit without screw fixation: discussion of a biomechanical study.

Authors:  Akio Kanda; Kazuo Kaneko; Osamu Obayashi; Atsuhiko Mogami; Hideaki Iwase
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-04-07

7.  Reconstruction of the hip. A mathematical approach to determine optimum geometric relationships.

Authors:  R C Johnston; R A Brand; R D Crowninshield
Journal:  J Bone Joint Surg Am       Date:  1979-07       Impact factor: 5.284

8.  Determination of muscle loading at the hip joint for use in pre-clinical testing.

Authors:  M O Heller; G Bergmann; J-P Kassi; L Claes; N P Haas; G N Duda
Journal:  J Biomech       Date:  2005-05       Impact factor: 2.712

9.  High placement of porous-coated acetabular components in complex total hip arthroplasty.

Authors:  S F Schutzer; W H Harris
Journal:  J Arthroplasty       Date:  1994-08       Impact factor: 4.757

10.  Cementless acetabular reconstruction and structural bone-grafting in dysplastic hips.

Authors:  C Hendrich; I Mehling; U Sauer; S Kirschner; J M Martell
Journal:  J Bone Joint Surg Am       Date:  2006-02       Impact factor: 5.284

View more
  2 in total

1.  Finite Element Analysis of Stress Distribution in Flat and Elevated-Rim Polyethylene Acetabular Liners.

Authors:  Nobuhiro Kaku; Ai Tanaka; Hiroaki Tagomori; Hiroshi Tsumura
Journal:  Clin Orthop Surg       Date:  2020-06-29

2.  Mid-term results in revision hip arthroplasty with impaction bone grafted cup reconstruction for acetabular defects.

Authors:  Sebastian Rohe; Nicoletta Dörr; Sabrina Böhle; Georg Matziolis; Steffen Brodt; Eric Röhner
Journal:  Sci Rep       Date:  2022-08-03       Impact factor: 4.996

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.