Literature DB >> 20824407

The incidence of acetabular osteolysis in young patients with conventional versus highly crosslinked polyethylene.

Nathan A Mall1, Ryan M Nunley, Jin Jun Zhu, William J Maloney, Robert L Barrack, John C Clohisy.   

Abstract

BACKGROUND: Osteolysis is a major mode of hip implant failure. Previous literature has focused on the amount of polyethylene wear comparing highly crosslinked polyethylene (HXPLE) with conventional liners but has not clarified the relative incidence of osteolysis with these two liners. QUESTIONS/PURPOSES: We determined (1) the incidence of osteolysis in HXLPE versus conventional polyethylene (CPE), (2) the ability to detect and evaluate the size of lytic lesions using radiographs compared with CT scans, (3) head penetration in hips without and with lysis, and (4) determined whether acetabular position, head size, and UCLA activity score contributed to lysis.
METHODS: We compared head penetration and osteolysis on plain radiographs and presence and volume of osteolysis on CT scans in 48 patients with HXLPE (mean, 46.5 years) and 50 patients with CPE (mean, 43.2 years). The minimum followup was 5 years (average, 7.2 years; range, 5.1-10.9 years),
RESULTS: Osteolysis was apparent on CT in a larger number of patients with CPE liners than HXLPE liners: 12 of 50 (24%) versus one of 48 (2%), respectively. We found no correlation between head penetration and volume of osteolytic lesions. Head penetration was greater in patients with osteolysis. Smaller head sizes were associated with greater wear and those with osteolysis had smaller head sizes; however, there was no difference in acetabular component position or UCLA activity in those with lysis compared with those without.
CONCLUSIONS: HXLPE diminished the incidence of osteolysis, but the lack of correlation between penetration and volume of osteolysis suggests other factors other than wear contribute to the development of osteolysis. LEVEL OF EVIDENCE: Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 20824407      PMCID: PMC3018187          DOI: 10.1007/s11999-010-1518-y

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  47 in total

1.  Clinical and radiographic evaluation of the Harris-Galante cup: incidence of wear and osteolysis at 7 to 9 years follow-up.

Authors:  M O Soto; J A Rodriguez; C S Ranawat
Journal:  J Arthroplasty       Date:  2000-02       Impact factor: 4.757

2.  Reasons for revision hip surgery: a retrospective review.

Authors:  John C Clohisy; George Calvert; Frank Tull; Douglas McDonald; William J Maloney
Journal:  Clin Orthop Relat Res       Date:  2004-12       Impact factor: 4.176

3.  Update on UHMWPE research: from the bench to the bedside.

Authors:  Enrique Gomez-Barrena; José-Antonio Puertolas; Luis Munuera; Yrjö T Konttinen
Journal:  Acta Orthop       Date:  2008-12       Impact factor: 3.717

4.  Determination of polyethylene wear in total hip replacements with use of digital radiographs.

Authors:  J M Martell; S Berdia
Journal:  J Bone Joint Surg Am       Date:  1997-11       Impact factor: 5.284

5.  Effect of femoral head size on wear of the polyethylene acetabular component.

Authors:  J Livermore; D Ilstrup; B Morrey
Journal:  J Bone Joint Surg Am       Date:  1990-04       Impact factor: 5.284

6.  The John Charnley Award. Wear is a function of use, not time.

Authors:  T P Schmalzried; E F Shepherd; F J Dorey; W O Jackson; M dela Rosa; F Fa'vae; H A McKellop; C D McClung; J Martell; J R Moreland; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  2000-12       Impact factor: 4.176

7.  THA with highly cross-linked polyethylene in patients 50 years or younger.

Authors:  Derek S Shia; John C Clohisy; Mark F Schinsky; John M Martell; William J Maloney
Journal:  Clin Orthop Relat Res       Date:  2009-01-14       Impact factor: 4.176

8.  Effect of femoral head size on polyethylene wear and synovitis after total hip arthroplasty: a sonographic and radiographic study of 39 patients.

Authors:  Sarunas Tarasevicius; Otto Robertsson; Uldis Kesteris; Romas Jonas Kalesinskas; Hans Wingstrand
Journal:  Acta Orthop       Date:  2008-08       Impact factor: 3.717

Review 9.  Aseptic loosening of total joint replacements: mechanisms underlying osteolysis and potential therapies.

Authors:  Yousef Abu-Amer; Isra Darwech; John C Clohisy
Journal:  Arthritis Res Ther       Date:  2007       Impact factor: 5.156

10.  Pelvic osteolysis relationship to radiographs and polyethylene wear.

Authors:  Won Yong Shon; Siddhartha Gupta; Sandeep Biswal; Sang Hwan Han; Suk Joo Hong; Jun Gyu Moon
Journal:  J Arthroplasty       Date:  2008-06-13       Impact factor: 4.757

View more
  21 in total

Review 1.  Periprosthetic osteolysis after total hip replacement: molecular pathology and clinical management.

Authors:  Donald W Howie; Susan D Neale; David R Haynes; Oksana T Holubowycz; Margaret A McGee; Lucian B Solomon; Stuart A Callary; Gerald J Atkins; David M Findlay
Journal:  Inflammopharmacology       Date:  2013-10-15       Impact factor: 4.473

2.  Wear and Osteolysis of Highly Crosslinked Polyethylene at 10 to 14 Years: The Effect of Femoral Head Size.

Authors:  Paul F Lachiewicz; Elizabeth S Soileau; John M Martell
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

Review 3.  Polyethylene and metal wear particles: characteristics and biological effects.

Authors:  Isabelle Catelas; Markus A Wimmer; Sandra Utzschneider
Journal:  Semin Immunopathol       Date:  2011-01-26       Impact factor: 9.623

Review 4.  Has total hip arthroplasty in patients 30 years or younger improved? A systematic review.

Authors:  Muyibat A Adelani; James A Keeney; Allison Palisch; Susan A Fowler; John C Clohisy
Journal:  Clin Orthop Relat Res       Date:  2013-04-06       Impact factor: 4.176

5.  Role of polyethylene particles in peri-prosthetic osteolysis: A review.

Authors:  Gerald J Atkins; David R Haynes; Donald W Howie; David M Findlay
Journal:  World J Orthop       Date:  2011-10-18

6.  Highly crosslinked polyethylene improves wear but not surface damage in retrieved acetabular liners.

Authors:  Hee-Nee Pang; Douglas D R Naudie; Richard W McCalden; Steven J MacDonald; Matthew G Teeter
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

7.  Does standing affect acetabular component inclination and version after THA?

Authors:  Gregory G Polkowski; Ryan M Nunley; Erin L Ruh; Brandon M Williams; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

8.  Sciatic nerve compression by an extrapelvic cyst secondary to wear debris after a cementless total hip arthroplasty: A case report and literature review.

Authors:  Murat Mert; Yusuf Oztürkmen; Ethem Ayhan Unkar; Sinan Erdoğan; Onat Uzümcügil
Journal:  Int J Surg Case Rep       Date:  2013-07-29

9.  Polyethylene and highly cross-linked polyethylene for cemented total hip arthroplasty: A comparison of over ten-year clinical and radiographic results.

Authors:  Tomotoshi Kawata; Koji Goto; Kazutaka So; Yutaka Kuroda; Shuichi Matsuda
Journal:  J Orthop       Date:  2017-08-10

10.  The 2012 John Charnley Award: Clinical multicenter studies of the wear performance of highly crosslinked remelted polyethylene in THA.

Authors:  Charles R Bragdon; Michael Doerner; John Martell; Bryan Jarrett; Henrik Palm; Henrik Malchau
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.