Literature DB >> 11127668

The John Charnley Award. Wear is a function of use, not time.

T P Schmalzried1, E F Shepherd, F J Dorey, W O Jackson, M dela Rosa, F Fa'vae, H A McKellop, C D McClung, J Martell, J R Moreland, H C Amstutz.   

Abstract

Polyethylene wear (linear penetration) in 37 hip replacements was assessed from digital images using a validated two-dimensional, edge detection-based computer algorithm. Patient activity was assessed with a pedometer, a step activity monitor and a simple visual analog scale. Joint use was related to wear at the 90% confidence level. Without three recognized outliers, wear was highly correlated to use. The visual analog scale activity rating was significantly related to wear for the 24 hip replacements with standard polyethylene. Univariate regression analysis indicated that male gender, height, weight (which were both highly correlated to male gender) and hip center of rotation were significantly correlated to wear. Multivariate regression analysis indicated that male gender, femoral off-set, and Hylamer were significantly correlated to wear. Based on the wear and activity data from the 24 hip replacements with standard polyethylene, the average volumetric wear rate per million cycles with a 70 kg patient weight was 30 mm3. This unique in vivo result can be considered a target wear rate for standard polyethylene in hip simulator studies.

Entities:  

Mesh:

Year:  2000        PMID: 11127668     DOI: 10.1097/00003086-200012000-00005

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  103 in total

Review 1.  Utility of pedometers for assessing physical activity: convergent validity.

Authors:  Catrine Tudor-Locke; Joel E Williams; Jared P Reis; Delores Pluto
Journal:  Sports Med       Date:  2002       Impact factor: 11.136

2.  The incidence of acetabular osteolysis in young patients with conventional versus highly crosslinked polyethylene.

Authors:  Nathan A Mall; Ryan M Nunley; Jin Jun Zhu; William J Maloney; Robert L Barrack; John C Clohisy
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

3.  Early polyethylene wear and osteolysis with ABG acetabular cups (7- to 12-year follow-up).

Authors:  Sachin Badhe; Peter Livesley
Journal:  Int Orthop       Date:  2005-11-08       Impact factor: 3.075

Review 4.  [Musculoskeletal load analysis. A biomechanical explanation for clinical results--and more?].

Authors:  M O Heller; J H Schröder; G Matziolis; A Sharenkov; W R Taylor; C Perka; G N Duda
Journal:  Orthopade       Date:  2007-03       Impact factor: 1.087

5.  Does impact sport activity influence total hip arthroplasty durability?

Authors:  Matthieu Ollivier; Solenne Frey; Sebastien Parratte; Xavier Flecher; Jean-Noël Argenson
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

Review 6.  Sports activity after total hip and knee arthroplasty : specific recommendations concerning tennis.

Authors:  Thorsten M Seyler; Michael A Mont; Phillip S Ragland; Munaf M Kachwala; Ronald E Delanois
Journal:  Sports Med       Date:  2006       Impact factor: 11.136

7.  Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty.

Authors:  Jiri Gallo; Vitezslav Havranek; Jana Zapletalova
Journal:  Int Orthop       Date:  2009-02-13       Impact factor: 3.075

Review 8.  Revision arthroplasty: an update.

Authors:  D Williams; A Taylor; P McLardy-Smith
Journal:  Skeletal Radiol       Date:  2009-11       Impact factor: 2.199

9.  Cementless Total Hip Arthroplasty With Metasul Bearings Provides Good Results in Active Young Patients: A Concise Followup.

Authors:  Christian P Delaunay; Sophie Putman; Benjamin Puliéro; Matthieu Bégin; Henri Migaud; François Bonnomet
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

10.  Risk of complication and revision total hip arthroplasty among Medicare patients with different bearing surfaces.

Authors:  Kevin J Bozic; Kevin Ong; Edmund Lau; Steven M Kurtz; Thomas P Vail; Harry E Rubash; Daniel J Berry
Journal:  Clin Orthop Relat Res       Date:  2010-09       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.