Vitamin E diffused, highly crosslinked UHMWPE: a review.

Ebru Oral1, Orhun K Muratoglu.   

Abstract

Highly crosslinked UHMWPE has become the bearing surface of choice in total hip arthroplasty. First generation crosslinked UHMWPEs, clinically introduced in the 1990s, show significant improvements compared to gamma sterilised, conventional UHMWPE in decreasing wear and osteolysis. These crosslinked UHMWPEs were thermally treated (annealed or melted) after irradiation to improve their oxidation resistance. While annealing resulted in the retention of some oxidation potential, post-irradiation melted UHMWPEs had reduced fatigue strength due to the crystallinity loss during melting. Thus, the stabilisation of radiation crosslinked UHMWPEs by the diffusion of the antioxidant vitamin E was developed to obtain oxidation resistance with improved fatigue strength by avoiding post-irradiation melting. A two-step process was developed to incorporate vitamin E into irradiated UHMWPE by diffusion to obtain a uniform concentration profile. Against accelerated and real-time aging in vitro, this material showed superior oxidation resistance to UHMWPEs with residual free radicals. The fatigue strength was improved compared to irradiated and melted UHMWPEs crosslinked using the same irradiation dose. Several adverse testing schemes simulating impingement showed satisfactory behaviour. Peri-prosthetic tissue reaction to vitamin E was evaluated in rabbits and any effects of vitamin E on device fixation were evaluated in a canine model, both of which showed no detrimental effects of the inclusion of vitamin E in crosslinked UHMWPE. Irradiated, vitamin E-diffused, and gamma sterilised UHMWPEs have been in clinical use in hips since 2007 and in knees since 2008. The clinical outcome of this material will be apparent from the results of prospective, randomised clinical studies.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21120476      PMCID: PMC3032101          DOI: 10.1007/s00264-010-1161-y

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  47 in total

Review 1.  Vitamin E: antioxidant activity, biokinetics, and bioavailability.

Authors:  G W Burton; M G Traber
Journal:  Annu Rev Nutr       Date:  1990       Impact factor: 11.848

2.  Cracking and impingement in ultra-high-molecular-weight polyethylene acetabular liners.

Authors:  Michael V Birman; Philip C Noble; Michael A Conditt; Steve Li; Kenneth B Mathis
Journal:  J Arthroplasty       Date:  2005-10       Impact factor: 4.757

3.  Effect of femoral head size on wear of the polyethylene acetabular component.

Authors:  J Livermore; D Ilstrup; B Morrey
Journal:  J Bone Joint Surg Am       Date:  1990-04       Impact factor: 5.284

4.  Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty.

Authors:  D H Sochart
Journal:  Clin Orthop Relat Res       Date:  1999-06       Impact factor: 4.176

5.  Evaluation of oxidation and fatigue damage of retrieved crossfire polyethylene acetabular cups.

Authors:  Barbara H Currier; John H Currier; Michael B Mayor; Kimberly A Lyford; John P Collier; Douglas W Van Citters
Journal:  J Bone Joint Surg Am       Date:  2007-09       Impact factor: 5.284

6.  Clinical performance of a highly cross-linked polyethylene at two years in total hip arthroplasty: a randomized prospective trial.

Authors:  John M Martell; James J Verner; Stephen J Incavo
Journal:  J Arthroplasty       Date:  2003-10       Impact factor: 4.757

7.  5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets: two randomized studies using radiostereometric analysis.

Authors:  Georgios Digas; Johan Kärrholm; Jonas Thanner; Peter Herberts
Journal:  Acta Orthop       Date:  2007-12       Impact factor: 3.717

8.  In vivo UHMWPE biodegradation of retrieved prosthesis.

Authors:  L Costa; M P Luda; L Trossarelli; E M Brach del Prever; M Crova; P Gallinaro
Journal:  Biomaterials       Date:  1998-08       Impact factor: 12.479

9.  Oxidation in orthopaedic UHMWPE sterilized by gamma-radiation and ethylene oxide.

Authors:  L Costa; M P Luda; L Trossarelli; E M Brach del Prever; M Crova; P Gallinaro
Journal:  Biomaterials       Date:  1998 Apr-May       Impact factor: 12.479

10.  Effect of radiation, heat, and aging on in vitro wear resistance of polyethylene.

Authors:  Orhun K Muratoglu; Edward W Merrill; Charles R Bragdon; Daniel O'Connor; Daniel Hoeffel; Brian Burroughs; Murali Jasty; William H Harris
Journal:  Clin Orthop Relat Res       Date:  2003-12       Impact factor: 4.176

View more
  34 in total

Review 1.  Periprosthetic osteolysis after total hip replacement: molecular pathology and clinical management.

Authors:  Donald W Howie; Susan D Neale; David R Haynes; Oksana T Holubowycz; Margaret A McGee; Lucian B Solomon; Stuart A Callary; Gerald J Atkins; David M Findlay
Journal:  Inflammopharmacology       Date:  2013-10-15       Impact factor: 4.473

Review 2.  Is there evidence for a superior method of socket fixation in hip arthroplasty? A systematic review.

Authors:  Dean Pakvis; Gijs van Hellemondt; Enrico de Visser; Wilco Jacobs; Maarten Spruit
Journal:  Int Orthop       Date:  2011-03-15       Impact factor: 3.075

3.  Total Hip Arthroplasty, state of the art for the 21st century.

Authors:  Jean-Pierre Courpied; Jacques Henri Caton
Journal:  Int Orthop       Date:  2011-01-18       Impact factor: 3.075

4.  Biological activity and migration of wear particles in the knee joint: an in vivo comparison of six different polyethylene materials.

Authors:  S Utzschneider; V Lorber; M Dedic; A C Paulus; C Schröder; O Gottschalk; M Schmitt-Sody; V Jansson
Journal:  J Mater Sci Mater Med       Date:  2014-02-22       Impact factor: 3.896

5.  Best one hundred papers of International Orthopaedics: a bibliometric analysis.

Authors:  Andreas F Mavrogenis; Panayiotis D Megaloikonomos; Georgios N Panagopoulos; Cyril Mauffrey; Andrew Quaile; Marius M Scarlat
Journal:  Int Orthop       Date:  2017-01-04       Impact factor: 3.075

Review 6.  Acetabular reinforcement rings associated with allograft for severe acetabular defects.

Authors:  Emmanuel Gibon; Luc Kerboull; Jean-Pierre Courpied; Moussa Hamadouche
Journal:  Int Orthop       Date:  2018-09-13       Impact factor: 3.075

7.  Vitamin-E diffused highly cross-linked polyethylene liner compared to standard liners in total hip arthroplasty. A randomized, controlled trial.

Authors:  Mats Salemyr; Olle Muren; Torbjörn Ahl; Henrik Bodén; Ghazi Chammout; André Stark; Olof Sköldenberg
Journal:  Int Orthop       Date:  2015-01-29       Impact factor: 3.075

8.  Joint replacement surgery and the innate immune system.

Authors:  Stuart B Goodman; Yrjo T Konttinen; Michiaki Takagi
Journal:  J Long Term Eff Med Implants       Date:  2014

9.  Antioxidant impregnated ultra-high molecular weight polyethylene wear debris particles display increased bone remodeling and a superior osteogenic:osteolytic profile vs. conventional UHMWPE particles in a murine calvaria model.

Authors:  Yu Chen; Nadim J Hallab; Yen-Shuo Liao; Venkat Narayan; Edward M Schwarz; Chao Xie
Journal:  J Orthop Res       Date:  2015-11-23       Impact factor: 3.494

Review 10.  Highly cross-linked polyethylene may not have an advantage in total knee arthroplasty.

Authors:  Vasileios I Sakellariou; Peter Sculco; Lazaros Poultsides; Timothy Wright; Thomas P Sculco
Journal:  HSS J       Date:  2013-08-10