Literature DB >> 17278805

Dose and image quality for a cone-beam C-arm CT system.

Rebecca Fahrig1, Robert Dixon, Thomas Payne, Richard L Morin, Arundhuti Ganguly, Norbert Strobel.   

Abstract

We assess dose and image quality of a state-of-the-art angiographic C-arm system (Axiom Artis dTA, Siemens Medical Solutions, Forchheim, Germany) for three-dimensional neuro-imaging at various dose levels and tube voltages and an associated measurement method. Unlike conventional CT, the beam length covers the entire phantom, hence, the concept of computed tomography dose index (CTDI) is not the metric of choice, and one can revert to conventional dosimetry methods by directly measuring the dose at various points using a small ion chamber. This method allows us to define and compute a new dose metric that is appropriate for a direct comparison with the familiar CTDIw of conventional CT. A perception study involving the CATPHAN 600 indicates that one can expect to see at least the 9 mm inset with 0.5% nominal contrast at the recommended head-scan dose (60 mGy) when using tube voltages ranging from 70 kVp to 125 kVp. When analyzing the impact of tube voltage on image quality at a fixed dose, we found that lower tube voltages gave improved low contrast detectability for small-diameter objects. The relationships between kVp, image noise, dose, and contrast perception are discussed.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17278805     DOI: 10.1118/1.2370508

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  53 in total

1.  Antiscatter grids in mobile C-arm cone-beam CT: effect on image quality and dose.

Authors:  S Schafer; J W Stayman; W Zbijewski; C Schmidgunst; G Kleinszig; J H Siewerdsen
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

2.  Three-dimensional anisotropic adaptive filtering of projection data for noise reduction in cone beam CT.

Authors:  Andreas Maier; Lars Wigstrom; Hannes G Hofmann; Joachim Hornegger; Lei Zhu; Norbert Strobel; Rebecca Fahrig
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

3.  Cone-beam computed tomography arthrography: an innovative modality for the evaluation of wrist ligament and cartilage injuries.

Authors:  Reeta Ramdhian-Wihlm; Jean-Marie Le Minor; Matthieu Schmittbuhl; Jeremy Jeantroux; Peter Mac Mahon; Francis Veillon; Jean-Claude Dosch; Jean-Louis Dietemann; Guillaume Bierry
Journal:  Skeletal Radiol       Date:  2011-11-08       Impact factor: 2.199

4.  Dose and detectability for a cone-beam C-arm CT system revisited.

Authors:  Arundhuti Ganguly; Sungwon Yoon; Rebecca Fahrig
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

5.  Developing low-dose C-arm CT imaging for temporomandibular joint (TMJ) disorder in interventional radiology.

Authors:  Xiaowei Zhu; Marc Felice; Laura Johnson; Marily Sarmiento; Anne Marie Cahill
Journal:  Pediatr Radiol       Date:  2010-11-16

6.  Low-dose computed tomography of the paranasal sinus and facial skull using a high-pitch dual-source system--first clinical results.

Authors:  Boris Schell; Ralf W Bauer; Thomas Lehnert; J Matthias Kerl; Markus Hambek; Angelika May; Thomas J Vogl; Martin G Mack
Journal:  Eur Radiol       Date:  2010-07-20       Impact factor: 5.315

7.  Practical dose point-based methods to characterize dose distribution in a stationary elliptical body phantom for a cone-beam C-arm CT system.

Authors:  Jang-Hwan Choi; Dragos Constantin; Arundhuti Ganguly; Erin Girard; Richard L Morin; Robert L Dixon; Rebecca Fahrig
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

Review 8.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

9.  A Convex Reconstruction Model for X-ray Tomographic Imaging with Uncertain Flat-fields.

Authors:  Hari Om Aggrawal; Martin S Andersen; Sean Rose; Emil Y Sidky
Journal:  IEEE Trans Comput Imaging       Date:  2017-07-04

10.  Experimental study of intracranial hematoma detection with flat panel detector C-arm CT.

Authors:  H Arakawa; M P Marks; H M Do; D M Bouley; N Strobel; T Moore; R Fahrig
Journal:  AJNR Am J Neuroradiol       Date:  2008-01-17       Impact factor: 3.825