Literature DB >> 7322067

A method for describing the doses delivered by transmission x-ray computed tomography.

T B Shope, R M Gagne, G C Johnson.   

Abstract

A method for describing the absorbed dose delivered by x-ray transmission computed tomography (CT) is proposed which provides a means to characterize the dose resulting from CT procedures consisting of a series of adjacent scans. The dose descriptor chosen is the average dose at several locations in the imaged volume of the central scan of the series. It is shown that this average dose, as defined, for locations in the central scan of the series can be obtained from the integral of the dose profile perpendicular to the scan plane at these same locations for a single scan. This method for estimating the average dose from a CT procedure has been evaluated as a function of the number of scans in the multiple scan procedure and location in the dosimetry phantom using single scan dose profiles obtained from five different types of CT systems. For the higher dose regions in the phantoms, the multiple scan dose descriptor derived from the single scan dose profiles overestimates the multiple scan average dose by no more than 10%, provided the procedure consists of at least eight scans.

Mesh:

Year:  1981        PMID: 7322067     DOI: 10.1118/1.594995

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  58 in total

1.  Effective dose values in bone mineral measurements by photon absorptiometry and computed tomography.

Authors:  W A Kalender
Journal:  Osteoporos Int       Date:  1992-03       Impact factor: 4.507

2.  Cone beam CT dosimetry: a unified and self-consistent approach including all scan modalities--with or without phantom motion.

Authors:  Robert L Dixon; John M Boone
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

3.  Implementation of radiochromic film dosimetry protocol for volumetric dose assessments to various organs during diagnostic CT procedures.

Authors:  Samuel Brady; Terry Yoshizumi; Greta Toncheva; Donald Frus
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

4.  Practical dose point-based methods to characterize dose distribution in a stationary elliptical body phantom for a cone-beam C-arm CT system.

Authors:  Jang-Hwan Choi; Dragos Constantin; Arundhuti Ganguly; Erin Girard; Richard L Morin; Robert L Dixon; Rebecca Fahrig
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

5.  Dosimetric assessment of the exposure of radiotherapy patients due to cone-beam CT procedures.

Authors:  Mariana Baptista; Salvatore Di Maria; Sandra Vieira; Joana Santos; Joana Pereira; Miguel Pereira; Pedro Vaz
Journal:  Radiat Environ Biophys       Date:  2018-11-03       Impact factor: 1.925

Review 6.  Techniques and parameters for estimating radiation exposure and dose in cardiac computed tomography.

Authors:  Thomas C Gerber; Ronald S Kuzo; Richard L Morin
Journal:  Int J Cardiovasc Imaging       Date:  2005-02       Impact factor: 2.357

7.  Aorto-iliac multidetector-row CT angiography with low kV settings: improved vessel enhancement and simultaneous reduction of radiation dose.

Authors:  B Wintersperger; T Jakobs; P Herzog; S Schaller; K Nikolaou; C Suess; C Weber; M Reiser; C Becker
Journal:  Eur Radiol       Date:  2004-12-21       Impact factor: 5.315

Review 8.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

9.  Variability of surface and center position radiation dose in MDCT: Monte Carlo simulations using CTDI and anthropomorphic phantoms.

Authors:  Di Zhang; Ali S Savandi; John J Demarco; Chris H Cagnon; Erin Angel; Adam C Turner; Dianna D Cody; Donna M Stevens; Andrew N Primak; Cynthia H McCollough; Michael F McNitt-Gray
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

10.  Radiation exposure of multi-row detector spiral computed tomography of the pulmonary arteries: comparison with digital subtraction pulmonary angiography.

Authors:  Jan W Kuiper; Jacob Geleijns; Niels A A Matheijssen; Wouter Teeuwisse; Peter M T Pattynama
Journal:  Eur Radiol       Date:  2002-11-13       Impact factor: 5.315