Angiographic C-arm CT visualization of the Woven EndoBridge cerebral aneurysm embolization device (WEB): first experience in an animal aneurysm model.

T Struffert1, S Lang, E Adamek, T Engelhorn, C M Strother, A Doerfler.   

Abstract

INTRODUCTION: Improvements in the imaging capabilities of angiographic C-arm computed tomography (CT) using flat detector angiographic (FD-CT) systems now provide a means for the in vivo visualization of devices used for the treatment of intracranial aneurysms. One such device, the WEB embolization device, is made of a braided mesh of nitinol wires, the size of which are near to the limits of visualization using conventional x-ray fluoroscopy. Our hypothesis was that the imaging of these implants C-arm CT would provide useful information regarding their positioning and deployment.
METHODS: In five New Zealand white rabbits elastase induced aneurysms were created and subsequently treated using a WEB. Imaging was performed using digital subtraction angiography (DSA), X-ray imaging and two different Angiographic C-arm CT protocols. The images were evaluated by two neuroradiologists using an evaluation scale.
RESULTS: The mesh of the WEB was barely visible on the DSA or x-ray fluoroscopy images. Volume rendering technique (VRT) reconstruction and multiplanar reconstruction (MPR) of images done using the C-arm CT protocols clearly delineated the shape and structure of the device. Contrast-enhanced MPR and VRT reconstructions allowed assessment of the status of blood flow in the aneurysms. Beam hardening artifacts caused by platinum markers on the WEB were present.
CONCLUSION: In vivo C-arm CT imaging of the WEB is feasible and allows precise determination of the position and deployment status of the device. On contrast-enhanced images the occlusion status of aneurysms and the positioning of the WEB in relationship to the parent artery can be evaluated. C-arm-CT may serve as a minimal-invasive follow-up imaging modality.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23712863     DOI: 10.1007/s00062-013-0224-z

Source DB:  PubMed          Journal:  Clin Neuroradiol        ISSN: 1869-1439            Impact factor:   3.649


  25 in total

1.  Angiographic CT for intraprocedural monitoring of complex neuroendovascular procedures.

Authors:  J Pfaff; T Struffert; P Gölitz; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2012-04-05       Impact factor: 3.825

2.  Optimized intravenous Flat Detector CT for non-invasive visualization of intracranial stents: first results.

Authors:  Tobias Struffert; Stephan Kloska; Tobias Engelhorn; Yu Deuerling-Zheng; Sabine Ott; Marc Doelken; Marc Saake; Martin Köhrmann; Arnd Doerfler
Journal:  Eur Radiol       Date:  2010-08-14       Impact factor: 5.315

3.  Angiographic CT in cerebrovascular stenting.

Authors:  Götz Benndorf; Charles M Strother; Benjamin Claus; Ramin Naeini; Hesham Morsi; Richard Klucznik; Michael E Mawad
Journal:  AJNR Am J Neuroradiol       Date:  2005-08       Impact factor: 3.825

4.  Flat-detector computed tomography in the assessment of intracranial stents: comparison with multi detector CT and conventional angiography in a new animal model.

Authors:  Tobias Struffert; Sabine Ott; Edyta Adamek; Marc Schwarz; Tobias Engelhorn; Stephan Kloska; Yu Deuerling-Zheng; Arnd Doerfler
Journal:  Eur Radiol       Date:  2011-03-02       Impact factor: 5.315

5.  Endovascular creation of an in vivo bifurcation aneurysm model in rabbits.

Authors:  H J Cloft; T A Altes; W F Marx; R J Raible; S B Hudson; G A Helm; J W Mandell; M E Jensen; J E Dion; D F Kallmes
Journal:  Radiology       Date:  1999-10       Impact factor: 11.105

6.  Angiographic CT with intravenous contrast agent application for monitoring of intracranial flow diverting stents.

Authors:  Marc Saake; Tobias Struffert; Philipp Goelitz; Sabine Ott; Frank Seifert; Oliver Ganslandt; Arnd Doerfler
Journal:  Neuroradiology       Date:  2011-10-04       Impact factor: 2.804

7.  Measurement of quantifiable parameters by time-density curves in the elastase-induced aneurysm model: first results in the comparison of a flow diverter and a conventional aneurysm stent.

Authors:  Tobias Struffert; Sabine Ott; Markus Kowarschik; Frederik Bender; Edyta Adamek; Tobias Engelhorn; Philipp Gölitz; Stefan Lang; Charles M Strother; Arnd Doerfler
Journal:  Eur Radiol       Date:  2012-08-16       Impact factor: 5.315

8.  Flat-detector computed tomography with intravenous contrast material application in experimental aneurysms: comparison with multislice CT and conventional angiography.

Authors:  Tobias Struffert; Marc Doelken; Edyta Adamek; Marc Schwarz; Tobias Engelhorn; Stephan Kloska; Sabine Ott; Arnd Doerfler
Journal:  Acta Radiol       Date:  2010-05       Impact factor: 1.990

9.  The Woven EndoBridge: a new aneurysm occlusion device.

Authors:  Y H Ding; D A Lewis; R Kadirvel; D Dai; D F Kallmes
Journal:  AJNR Am J Neuroradiol       Date:  2011-02-17       Impact factor: 3.825

10.  Onyx in an experimental aneurysm model: histological and angiographic results.

Authors:  Tobias Struffert; Christian Roth; Bernd Romeike; Iris O Grunwald; Wolfgang Reith
Journal:  J Neurosurg       Date:  2008-07       Impact factor: 5.115

View more
  2 in total

Review 1.  From bench to bedside: utility of the rabbit elastase aneurysm model in preclinical studies of intracranial aneurysm treatment.

Authors:  Waleed Brinjikji; Yong H Ding; David F Kallmes; Ramanathan Kadirvel
Journal:  J Neurointerv Surg       Date:  2015-04-22       Impact factor: 5.836

2.  Metal artifact reduction for flat panel detector intravenous CT angiography in patients with intracranial metallic implants after endovascular and surgical treatment.

Authors:  Rastislav Pjontek; Belgin Önenköprülü; Bernhard Scholz; Yiannis Kyriakou; Gerrit A Schubert; Omid Nikoubashman; Ahmed Othman; Martin Wiesmann; Marc A Brockmann
Journal:  J Neurointerv Surg       Date:  2015-09-07       Impact factor: 5.836