Literature DB >> 21476020

C-arm cone beam computed tomography needle path overlay for image-guided procedures of the spine and pelvis.

Simon C Leschka1, Drazenko Babic, Samer El Shikh, Christine Wossmann, Martin Schumacher, Christian A Taschner.   

Abstract

INTRODUCTION: The aim of this study is to report our early clinical experience using C-arm cone beam computed tomography with fluoroscopic overlay for image guidance during percutaneous needle procedures of the spine and pelvis.
METHODS: Twelve consecutive patients (four female and eight male patients; mean age, 64 years; range, 47-74 years; SD ± 7.6 years) who underwent percutaneous biopsy of the spine and pelvis for suspected metastasis (n = 12), spondylodiscitis (n = 6), abscess (n = 5) or bone tumour (n = 1) were prospectively included between March 2009 and November 2010. The procedures were performed on the Allura Xper FD20/20 (Philips, Best, the Netherlands) using cone beam computed tomography (XperCT) with the C-arm combined with fluoroscopic overlay for needle guidance. Based on an initial XperCT, entry and target points were defined using dedicated guidance software (XperGuide). The needle path was visualised in various reconstructed planes and could be adjusted when considered necessary. For percutaneous interventions, the entry view (overlay of entry and target point in the bull's eye fashion), the progression view (perpendicular to the entry view) as well as two additional views could automatically be piloted to with the C-arm system. Needle navigation was supported by a biopsy guidance device (Seestar, Radi, Uppsala, Sweden). Correct needle positioning was confirmed with a second XperCT acquisition. Technical success was defined as any target point reached via the planned needle trajectory with a distance of final needle tip within 5 mm of the planned target point in any direction.
RESULTS: In all 12 patients, target areas could be defined based on XperCT data. In 11 of 12 (92%) cases, the target point was successfully reached on the planned trajectory with a mean error of 2.8 mm (range, 0.5-9.4 mm; SD, 2.4 mm). No peri- or post-interventional complications occurred.
CONCLUSION: XperCT-guided interventions with the XperGuide system seem a safe and reliable tool for percutaneous needle interventions of the spine and pelvis. The advantage of the technique when compared to CT- or fluoroscopy-guided interventions needs to be determined in a comparative study of a larger scale.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21476020     DOI: 10.1007/s00234-011-0866-y

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  15 in total

1.  Real-Time 3D fluoroscopy guidance during needle interventions: technique, accuracy, and feasibility.

Authors:  S J Braak; M J L van Strijen; M van Leersum; H W van Es; J P M van Heesewijk
Journal:  AJR Am J Roentgenol       Date:  2010-05       Impact factor: 3.959

2.  Effective dose of CT- and fluoroscopy-guided perineural/epidural injections of the lumbar spine: a comparative study.

Authors:  Gebhard Schmid; Alexander Schmitz; Dieter Borchardt; Klaus Ewen; Thomas von Rothenburg; Odo Koester; Michael Jergas
Journal:  Cardiovasc Intervent Radiol       Date:  2006 Jan-Feb       Impact factor: 2.740

Review 3.  Live 3D guidance in the interventional radiology suite.

Authors:  John M Racadio; Drazenko Babic; Robert Homan; John W Rampton; Manish N Patel; Judy M Racadio; Neil D Johnson
Journal:  AJR Am J Roentgenol       Date:  2007-12       Impact factor: 3.959

4.  Percutaneous spine biopsy: a meta-analysis.

Authors:  Ali Nourbakhsh; James J Grady; Kim J Garges
Journal:  J Bone Joint Surg Am       Date:  2008-08       Impact factor: 5.284

5.  Percutaneous CT-guided biopsy of the spine: results of 430 biopsies.

Authors:  Eugenio Rimondi; Eric L Staals; Costantino Errani; Giuseppe Bianchi; Roberto Casadei; Marco Alberghini; Maria Cristina Malaguti; Giuseppe Rossi; Stefano Durante; Mario Mercuri
Journal:  Eur Spine J       Date:  2008-05-08       Impact factor: 3.134

6.  Comparison of organ doses and image quality between CT and flat panel XperCT scans in wrist and inner ear examinations.

Authors:  J Damet; M Sans-Merce; F Miéville; M Becker; P A Poletti; F R Verdun; S Baechler
Journal:  Radiat Prot Dosimetry       Date:  2010-03-03       Impact factor: 0.972

7.  Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype.

Authors:  M J Daly; J H Siewerdsen; D J Moseley; D A Jaffray; J C Irish
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

8.  C-arm cone beam computed tomography needle path overlay for fluoroscopic guided vertebroplasty.

Authors:  Alda L Tam; Ashraf Mohamed; Marcus Pfister; Ponraj Chinndurai; Esther Rohm; Andrew F Hall; Michael J Wallace
Journal:  Spine (Phila Pa 1976)       Date:  2010-05-01       Impact factor: 3.468

9.  Brain imaging with a flat detector C-arm : Technique and clinical interest of XperCT.

Authors:  M Söderman; D Babic; S Holmin; T Andersson
Journal:  Neuroradiology       Date:  2008-06-17       Impact factor: 2.804

10.  Computer navigation in balloon kyphoplasty reduces the intraoperative radiation exposure.

Authors:  Kaywan Izadpanah; Gerhard Konrad; Norbert P Südkamp; Michael Oberst
Journal:  Spine (Phila Pa 1976)       Date:  2009-05-20       Impact factor: 3.468

View more
  15 in total

1.  Cone beam CT guidance provides superior accuracy for complex needle paths compared with CT guidance.

Authors:  W M H Busser; S J Braak; J J Fütterer; M J L van Strijen; Y L Hoogeveen; F de Lange; L J Schultze Kool
Journal:  Br J Radiol       Date:  2013-08-02       Impact factor: 3.039

2.  AngleNav: MEMS Tracker to Facilitate CT-Guided Puncture.

Authors:  Rui Li; Sheng Xu; William F Pritchard; John W Karanian; Venkatesh P Krishnasamy; Bradford J Wood; Zion Tsz Ho Tse
Journal:  Ann Biomed Eng       Date:  2018-01-05       Impact factor: 3.934

3.  C-Arm Cone-Beam CT Virtual Navigation-Guided Percutaneous Mediastinal Mass Biopsy: Diagnostic Accuracy and Complications.

Authors:  Hyungjin Kim; Chang Min Park; Sang Min Lee; Jin Mo Goo
Journal:  Eur Radiol       Date:  2015-04-28       Impact factor: 5.315

4.  The Urological Dyna-CT: ex vivo feasibility study of interventional cross-sectional imaging in the endourological operation room.

Authors:  M S Michel; M Ritter; H Wertz; S Schönberg; A Häcker; G Weisser
Journal:  World J Urol       Date:  2012-09-21       Impact factor: 4.226

5.  Computer-assisted fluoroscopic navigation of percutaneous spinal interventions.

Authors:  Jörg A K Ohnsorge; Khaled H Salem; Andreas Ladenburger; Uwe M Maus; Markus Weisskopf
Journal:  Eur Spine J       Date:  2012-09-13       Impact factor: 3.134

6.  [The urological Dyna-CT. Urological cross-sectional imaging on a newly developed urological intervention table].

Authors:  M S Michel; M Ritter; S Schönberg; A Häcker; G Weisser
Journal:  Urologe A       Date:  2012-06       Impact factor: 0.639

7.  Target visibility enhancement for C-arm cone beam CT-fluoroscopy-guided hepatic needle placement: implementation and accuracy evaluation.

Authors:  Mengjiao Wang; Hui Ding; Xiaodong Wang; Guangzhi Wang
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-05-16       Impact factor: 2.924

Review 8.  How I do it: Cone-beam CT during transarterial chemoembolization for liver cancer.

Authors:  Vania Tacher; Alessandro Radaelli; MingDe Lin; Jean-François Geschwind
Journal:  Radiology       Date:  2015-02       Impact factor: 11.105

9.  Real-time fluoroscopic needle guidance in the interventional radiology suite using navigational software for percutaneous bone biopsies in children.

Authors:  Sphoorti Shellikeri; Randolph M Setser; Tiffany J Hwang; Abhay Srinivasan; Ganesh Krishnamurthy; Seth Vatsky; Erin Girard; Xiaowei Zhu; Marc S Keller; Anne Marie Cahill
Journal:  Pediatr Radiol       Date:  2017-05-04

10.  Percutaneous vertebroplasty with the rotational fluoroscopy imaging technique.

Authors:  Alessandro Cannavale; Filippo Maria Salvatori; Andrea Wlderk; Carlo Cirelli; Alessandro d'Adamo; Fabrizio Fanelli
Journal:  Skeletal Radiol       Date:  2014-06-06       Impact factor: 2.199

View more