Originally aimed at improving standard radiography by providing higher absorption efficiency and a wider dynamic range than available with film-screen and phosphor luminescence, radiography flat detector technology is now widely accepted for neuroangiographic imaging. Especially flat-detector computed tomography (FD-CT), which uses rotational C-arm mounted flat-panel detector technology, is capable of volumetric imaging with a high spatial resolution. As "angiographic CT" FD-CT may be helpful in many diagnostic and neurointerventional procedures, e.g. intracranial stenting for cerebrovascular stenoses, stent-assisted coil embolization of wide-necked cerebral aneurysms and embolization of arteriovenous malformations. By providing morphologic, CT-like images of the brain within the angiography suite FD-CT allows rapid visualization of periprocedural hemorrhaging and may thus improve rapid complication management without the need of patient transfer. In addition, myelography and postmyelographic FD-CT imaging can be carried out using a single modality. Spinal interventions, such as kyphoplasty or vertebroplasty might also benefit from FD-CT. Imaging of the temporal bone may also develop into an important field of FD-CT. This paper briefly reviews the technical principles of FD technology and the potential applications in diagnostic and interventional neuroradiology.

Entities:  

Mesh:

Year:  2009        PMID: 19727642     DOI: 10.1007/s00117-009-1861-8

Source DB:  PubMed          Journal:  Radiologe        ISSN: 0033-832X            Impact factor:   0.635


  29 in total

1.  Strategies to improve the signal and noise performance of active matrix, flat-panel imagers for diagnostic x-ray applications.

Authors:  L E Antonuk; K W Jee; Y El-Mohri; M Maolinbay; S Nassif; X Rong; Q Zhao; J H Siewerdsen; R A Street; K S Shah
Journal:  Med Phys       Date:  2000-02       Impact factor: 4.071

2.  Flat-panel volume computed tomography for cochlear implant electrode array examination in isolated temporal bone specimens.

Authors:  Soenke H Bartling; Rajiv Gupta; Attila Torkos; Christian Dullin; Grabbe Eckhardt; Thomas Lenarz; Hartmut Becker; Timo Stöver
Journal:  Otol Neurotol       Date:  2006-06       Impact factor: 2.311

Review 3.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

4.  Use of a C-arm system to generate true three-dimensional computed rotational angiograms: preliminary in vitro and in vivo results.

Authors:  R Fahrig; A J Fox; S Lownie; D W Holdsworth
Journal:  AJNR Am J Neuroradiol       Date:  1997-09       Impact factor: 3.825

5.  Aneurysmal rupture during embolization with Guglielmi detachable coils: causes, management, and outcome.

Authors:  A Doerfler; I Wanke; T Egelhof; U Dietrich; S Asgari; D Stolke; M Forsting
Journal:  AJNR Am J Neuroradiol       Date:  2001 Nov-Dec       Impact factor: 3.825

6.  Intracranial angioplasty and stenting: long-term results from a single center.

Authors:  J C Wojak; D C Dunlap; K R Hargrave; L A DeAlvare; H S Culbertson; J J Connors
Journal:  AJNR Am J Neuroradiol       Date:  2006-10       Impact factor: 3.825

7.  Stenting of Symptomatic Atherosclerotic Lesions in the Vertebral or Intracranial Arteries (SSYLVIA): study results.

Authors: 
Journal:  Stroke       Date:  2004-04-22       Impact factor: 7.914

8.  Flat panel detector angiographic CT for stent-assisted coil embolization of broad-based cerebral aneurysms.

Authors:  G Richter; T Engelhorn; T Struffert; M Doelken; O Ganslandt; J Hornegger; W A Kalender; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2007-09-24       Impact factor: 3.825

9.  AngioCT in the management of neurointerventional patients: a prospective, consecutive series with associated dosimetry and resolution data.

Authors:  Philip M White; John N Gilmour; Nicholas W Weir; Brian Innes; Robin J Sellar
Journal:  Neuroradiology       Date:  2007-12-21       Impact factor: 2.804

10.  Treatment of wide-necked intracranial aneurysms with a self-expanding stent system: initial clinical experience.

Authors:  Isabel Wanke; Arnd Doerfler; Beate Schoch; Dietmar Stolke; Michael Forsting
Journal:  AJNR Am J Neuroradiol       Date:  2003 Jun-Jul       Impact factor: 3.825

View more
  5 in total

1.  [Cerebrovascular diagnostics: imaging].

Authors:  C Roth
Journal:  Radiologe       Date:  2012-12       Impact factor: 0.635

2.  Real-time fluoroscopic needle guidance in the interventional radiology suite using navigational software for percutaneous bone biopsies in children.

Authors:  Sphoorti Shellikeri; Randolph M Setser; Tiffany J Hwang; Abhay Srinivasan; Ganesh Krishnamurthy; Seth Vatsky; Erin Girard; Xiaowei Zhu; Marc S Keller; Anne Marie Cahill
Journal:  Pediatr Radiol       Date:  2017-05-04

3.  The value of flat-detector computed tomography during catheterisation of congenital heart disease.

Authors:  Martin Glöckler; Andreas Koch; Verena Greim; Amira Shabaiek; Andrè Rüffer; Robert Cesnjevar; Stephan Achenbach; Sven Dittrich
Journal:  Eur Radiol       Date:  2011-07-28       Impact factor: 5.315

4.  Flat detector angio-CT following intra-arterial therapy of acute ischemic stroke: identification of hemorrhage and distinction from contrast accumulation due to blood-brain barrier disruption.

Authors:  T Kau; M Hauser; S M Obmann; M Niedermayer; J R Weber; K A Hausegger
Journal:  AJNR Am J Neuroradiol       Date:  2014-06-19       Impact factor: 3.825

5.  [Radiation dose in cerebral angiography and flat detector CT applications in neuroradiology].

Authors:  T Struffert; S Lang; R Scholz; M Hauer; A Dörfler
Journal:  Radiologe       Date:  2015-08       Impact factor: 0.635

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.