Literature DB >> 18228604

Local B1+ shimming for prostate imaging with transceiver arrays at 7T based on subject-dependent transmit phase measurements.

Gregory J Metzger1, Carl Snyder, Can Akgun, Tommy Vaughan, Kamil Ugurbil, Pierre-Francois Van de Moortele.   

Abstract

High-quality prostate images were obtained with transceiver arrays at 7T after performing subject-dependent local transmit B(1) (B(1) (+)) shimming to minimize B(1) (+) losses resulting from destructive interferences. B(1) (+) shimming was performed by altering the input phase of individual RF channels based on relative B(1) (+) phase maps rapidly obtained in vivo for each channel of an eight-element stripline coil. The relative transmit phases needed to maximize B(1) (+) coherence within a limited region around the prostate greatly differed from those dictated by coil geometry and were highly subject-dependent. A set of transmit phases determined by B(1) (+) shimming provided a gain in transmit efficiency of 4.2 +/- 2.7 in the prostate when compared to the standard transmit phases determined by coil geometry. This increased efficiency resulted in large reductions in required RF power for a given flip angle in the prostate which, when accounted for in modeling studies, resulted in significant reductions of local specific absorption rates. Additionally, B(1) (+) shimming decreased B(1) (+) nonuniformity within the prostate from (24 +/- 9%) to (5 +/- 4%). This study demonstrates the tremendous impact of fast local B(1) (+) phase shimming on ultrahigh magnetic field body imaging. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2008        PMID: 18228604      PMCID: PMC4406352          DOI: 10.1002/mrm.21476

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  26 in total

1.  Analysis of wave behavior in lossy dielectric samples at high field.

Authors:  Qing X Yang; Jinghua Wang; Xiaoliang Zhang; Christopher M Collins; Michael B Smith; Haiying Liu; Xiao-Hong Zhu; J Thomas Vaughan; Kamil Ugurbil; Wei Chen
Journal:  Magn Reson Med       Date:  2002-05       Impact factor: 4.668

2.  Transmit SENSE.

Authors:  Ulrich Katscher; Peter Börnert; Christoph Leussler; Johan S van den Brink
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

3.  Transmit and receive transmission line arrays for 7 Tesla parallel imaging.

Authors:  Gregor Adriany; Pierre-Francois Van de Moortele; Florian Wiesinger; Steen Moeller; John P Strupp; Peter Andersen; Carl Snyder; Xiaoliang Zhang; Wei Chen; Klaas P Pruessmann; Peter Boesiger; Tommy Vaughan; Kāmil Uğurbil
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

Review 4.  Prostate MR imaging at high-field strength: evolution or revolution?

Authors:  Olivier Rouvière; Robert P Hartman; Denis Lyonnet
Journal:  Eur Radiol       Date:  2005-09-10       Impact factor: 5.315

Review 5.  Abdominal magnetic resonance imaging at 3.0 T: problem or a promise for the future?

Authors:  Shahid M Hussain; Piotr A Wielopolski; Diego R Martin
Journal:  Top Magn Reson Imaging       Date:  2005-07

6.  Manipulation of image intensity distribution at 7.0 T: passive RF shimming and focusing with dielectric materials.

Authors:  Qing X Yang; Weihua Mao; Jinghua Wang; Michael B Smith; Hao Lei; Xiaoliang Zhang; Kamil Ugurbil; Wei Chen
Journal:  J Magn Reson Imaging       Date:  2006-07       Impact factor: 4.813

7.  Transceive surface coil array for MRI of the human prostate at 4T.

Authors:  Robert G Pinkerton; James P Near; Enzo A Barberi; Ravi S Menon; Robert Bartha
Journal:  Magn Reson Med       Date:  2007-02       Impact factor: 4.668

8.  9.4T human MRI: preliminary results.

Authors:  Thomas Vaughan; Lance DelaBarre; Carl Snyder; Jinfeng Tian; Can Akgun; Devashish Shrivastava; Wanzahn Liu; Chris Olson; Gregor Adriany; John Strupp; Peter Andersen; Anand Gopinath; Pierre-Francois van de Moortele; Michael Garwood; Kamil Ugurbil
Journal:  Magn Reson Med       Date:  2006-12       Impact factor: 4.668

9.  Electromagnetic fields of surface coil in vivo NMR at high frequencies.

Authors:  J R Keltner; J W Carlson; M S Roos; S T Wong; T L Wong; T F Budinger
Journal:  Magn Reson Med       Date:  1991-12       Impact factor: 4.668

10.  High-field-strength MR imaging of the liver at 3.0 T: intraindividual comparative study with MR imaging at 1.5 T.

Authors:  Marcus M von Falkenhausen; Götz Lutterbey; Nuschin Morakkabati-Spitz; Oliver Walter; Jürgen Gieseke; Renate Blömer; Winfried A Willinek; Hans H Schild; Christiane K Kuhl
Journal:  Radiology       Date:  2006-08-14       Impact factor: 11.105

View more
  123 in total

1.  Current CONtrolled Transmit And Receive Coil Elements (CONTAR) for Parallel Acquisition and Parallel Excitation Techniques at High-Field MRI.

Authors:  E Kirilina; A Kühne; T Lindel; W Hoffmann; K H Rhein; T Riemer; F Seifert
Journal:  Appl Magn Reson       Date:  2011-08-21       Impact factor: 0.831

2.  A 32-channel lattice transmission line array for parallel transmit and receive MRI at 7 tesla.

Authors:  Gregor Adriany; Edward J Auerbach; Carl J Snyder; Ark Gözübüyük; Steen Moeller; Johannes Ritter; Pierre-François Van de Moortele; Tommy Vaughan; Kâmil Uğurbil
Journal:  Magn Reson Med       Date:  2010-06       Impact factor: 4.668

Review 3.  Magnetic resonance imaging at ultrahigh fields.

Authors:  Kamil Ugurbil
Journal:  IEEE Trans Biomed Eng       Date:  2014-03-25       Impact factor: 4.538

4.  Simultaneous bilateral hip joint imaging at 7 Tesla using fast transmit B₁ shimming methods and multichannel transmission - a feasibility study.

Authors:  J Ellermann; U Goerke; P Morgan; K Ugurbil; J Tian; S Schmitter; T Vaughan; P-F Van De Moortele
Journal:  NMR Biomed       Date:  2012-02-07       Impact factor: 4.044

5.  Brain imaging with improved acceleration and SNR at 7 Tesla obtained with 64-channel receive array.

Authors:  Kamil Uğurbil; Edward Auerbach; Steen Moeller; Andrea Grant; Xiaoping Wu; Pierre-Francois Van de Moortele; Cheryl Olman; Lance DelaBarre; Scott Schillak; Jerahmie Radder; Russell Lagore; Gregor Adriany
Journal:  Magn Reson Med       Date:  2019-02-25       Impact factor: 4.668

6.  Numerical and experimental evaluation of RF shimming in the human brain at 9.4 T using a dual-row transmit array.

Authors:  Jens Hoffmann; Gunamony Shajan; Klaus Scheffler; Rolf Pohmann
Journal:  MAGMA       Date:  2013-11-26       Impact factor: 2.310

7.  Image homogenization using pre-emphasis method for high field MRI.

Authors:  Ye Li; Chunsheng Wang; Baiying Yu; Daniel Vigneron; Wei Chen; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2013-08

8.  Mitigation of B1+ inhomogeneity using spatially selective excitation with jointly designed quadratic spatial encoding magnetic fields and RF shimming.

Authors:  Yi-Cheng Hsu; Riccardo Lattanzi; Ying-Hua Chu; Martijn A Cloos; Daniel K Sodickson; Fa-Hsuan Lin
Journal:  Magn Reson Med       Date:  2016-10-02       Impact factor: 4.668

9.  Image-guided radio-frequency gain calibration for high-field MRI.

Authors:  Elodie Breton; Kellyanne McGorty; Graham C Wiggins; Leon Axel; Daniel Kim
Journal:  NMR Biomed       Date:  2009-12-15       Impact factor: 4.044

10.  Parallel excitation in the human brain at 9.4 T counteracting k-space errors with RF pulse design.

Authors:  Xiaoping Wu; J Thomas Vaughan; Kâmil Uğurbil; Pierre-François Van de Moortele
Journal:  Magn Reson Med       Date:  2010-02       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.