Image-guided radio-frequency gain calibration for high-field MRI.

Elodie Breton1, Kellyanne McGorty, Graham C Wiggins, Leon Axel, Daniel Kim.   

Abstract

High-field (≥ 3T) MRI provides a means to increase the signal-to-noise ratio, due to its higher tissue magnetization compared with 1.5T. However, both the static magnetic field (B(0)) and the transmit radio-frequency (RF) field (B 1+) inhomogeneities are comparatively higher at higher field strengths than those at 1.5T. These challenging factors at high-field strengths make it more difficult to accurately calibrate the transmit RF gain using standard RF calibration procedures. An image-based RF calibration procedure was therefore developed, in order to accurately calibrate the transmit RF gain within a specific region-of-interest (ROI). Using a turbo fast low-angle shot (TurboFLASH) pulse sequence with centric k-space reordering, a series of 'saturation-no-recovery' images was acquired by varying the flip angle of the preconditioning pulse. In the resulting images, the signal null occurs in regions where the flip angle of the preconditioning pulse is 90°. For a given ROI, the mean signal can be plotted as a function of the nominal flip angle, and the resulting curve can be used to quantitatively identify the signal null. This image-guided RF calibration procedure was evaluated through phantom and volunteer imaging experiments at 3T and 7T. The image-guided RF calibration results in vitro were consistent with standard B(0) and B 1+ maps. The standard automated RF calibration procedure produced approximately 20% and 15-30% relative error in the transmit RF gain in the left kidney at 3T and brain at 7T, respectively. For initial application, a T(2) mapping pulse sequence was applied at 7T. The T(2) measurements in the thalamus at 7T were 60.6 ms and 48.2 ms using the standard and image-guided RF calibration procedures, respectively. This rapid, image-guided RF calibration procedure can be used to optimally calibrate the flip angle for a given ROI and thus minimize measurement errors for quantitative MRI and MR spectroscopy.
Copyright © 2009 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2009        PMID: 20014333      PMCID: PMC2988285          DOI: 10.1002/nbm.1471

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  29 in total

1.  Cardiac imaging at 4 Tesla.

Authors:  L Dougherty; T J Connick; G Mizsei
Journal:  Magn Reson Med       Date:  2001-01       Impact factor: 4.668

2.  Human cardiac imaging at 3 T using phased array coils.

Authors:  R Noeske; F Seifert; K H Rhein; H Rinneberg
Journal:  Magn Reson Med       Date:  2000-12       Impact factor: 4.668

3.  Magnetic resonance angiography at 3.0 Tesla: initial clinical experience.

Authors:  N G Campeau; J Huston; M A Bernstein; C Lin; G F Gibbs
Journal:  Top Magn Reson Imaging       Date:  2001-06

4.  Saturated double-angle method for rapid B1+ mapping.

Authors:  Charles H Cunningham; John M Pauly; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2006-06       Impact factor: 4.668

5.  Multicontrast black-blood MRI of carotid arteries: comparison between 1.5 and 3 tesla magnetic field strengths.

Authors:  Vasily L Yarnykh; Masahiro Terashima; Cecil E Hayes; Ann Shimakawa; Norihide Takaya; Patricia K Nguyen; Jean H Brittain; Michael V McConnell; Chun Yuan
Journal:  J Magn Reson Imaging       Date:  2006-05       Impact factor: 4.813

6.  Local B1+ shimming for prostate imaging with transceiver arrays at 7T based on subject-dependent transmit phase measurements.

Authors:  Gregory J Metzger; Carl Snyder; Can Akgun; Tommy Vaughan; Kamil Ugurbil; Pierre-Francois Van de Moortele
Journal:  Magn Reson Med       Date:  2008-02       Impact factor: 4.668

7.  Hybrid adiabatic-rectangular pulse train for effective saturation of magnetization within the whole heart at 3 T.

Authors:  Daniel Kim; Niels Oesingmann; Kellyanne McGorty
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

8.  Preliminary report on in vivo coronary MRA at 3 Tesla in humans.

Authors:  Matthias Stuber; René M Botnar; Stefan E Fischer; Rolf Lamerichs; Jouke Smink; Paul Harvey; Warren J Manning
Journal:  Magn Reson Med       Date:  2002-09       Impact factor: 4.668

9.  Breathhold multiecho fast spin-echo pulse sequence for accurate R2 measurement in the heart and liver.

Authors:  Daniel Kim; Jens H Jensen; Ed X Wu; Sujit S Sheth; Gary M Brittenham
Journal:  Magn Reson Med       Date:  2009-08       Impact factor: 4.668

10.  Cardiovascular magnetic resonance perfusion imaging at 3-tesla for the detection of coronary artery disease: a comparison with 1.5-tesla.

Authors:  Adrian S H Cheng; Tammy J Pegg; Theodoros D Karamitsos; Nick Searle; Michael Jerosch-Herold; Robin P Choudhury; Adrian P Banning; Stefan Neubauer; Matthew D Robson; Joseph B Selvanayagam
Journal:  J Am Coll Cardiol       Date:  2007-06-11       Impact factor: 24.094

View more
  11 in total

1.  Tailoring the flow sensitivity of fast spin-echo sequences for noncontrast peripheral MR angiography.

Authors:  Pippa Storey; Iliyana P Atanasova; Ruth P Lim; Jian Xu; Daniel Kim; Qun Chen; Vivian S Lee
Journal:  Magn Reson Med       Date:  2010-10       Impact factor: 4.668

2.  A nested phosphorus and proton coil array for brain magnetic resonance imaging and spectroscopy.

Authors:  Ryan Brown; Karthik Lakshmanan; Guillaume Madelin; Prodromos Parasoglou
Journal:  Neuroimage       Date:  2015-09-13       Impact factor: 6.556

3.  Improved localization, spectral quality, and repeatability with advanced MRS methodology in the clinical setting.

Authors:  Dinesh K Deelchand; Kejal Kantarci; Gülin Öz
Journal:  Magn Reson Med       Date:  2017-06-15       Impact factor: 4.668

4.  Breast MRI at 7 Tesla with a bilateral coil and robust fat suppression.

Authors:  Ryan Brown; Pippa Storey; Christian Geppert; KellyAnne McGorty; Ana Paula Klautau Leite; James Babb; Daniel K Sodickson; Graham C Wiggins; Linda Moy
Journal:  J Magn Reson Imaging       Date:  2013-10-07       Impact factor: 4.813

5.  Design and application of combined 8-channel transmit and 10-channel receive arrays and radiofrequency shimming for 7-T shoulder magnetic resonance imaging.

Authors:  Ryan Brown; Cem Murat Deniz; Bei Zhang; Gregory Chang; Daniel K Sodickson; Graham C Wiggins
Journal:  Invest Radiol       Date:  2014-01       Impact factor: 6.016

6.  High-resolution human cervical spinal cord imaging at 7 T.

Authors:  E E Sigmund; G A Suero; C Hu; K McGorty; D K Sodickson; G C Wiggins; J A Helpern
Journal:  NMR Biomed       Date:  2011-12-20       Impact factor: 4.044

7.  Rapid B1+ mapping using a preconditioning RF pulse with TurboFLASH readout.

Authors:  Sohae Chung; Daniel Kim; Elodie Breton; Leon Axel
Journal:  Magn Reson Med       Date:  2010-08       Impact factor: 4.668

8.  Design of a nested eight-channel sodium and four-channel proton coil for 7T knee imaging.

Authors:  Ryan Brown; Guillaume Madelin; Riccardo Lattanzi; Gregory Chang; Ravinder R Regatte; Daniel K Sodickson; Graham C Wiggins
Journal:  Magn Reson Med       Date:  2012-08-08       Impact factor: 4.668

9.  Automated whole-brain N-acetylaspartate proton MRS quantification.

Authors:  Brian J Soher; William E Wu; Assaf Tal; Pippa Storey; Ke Zhang; James S Babb; Ivan I Kirov; Yvonne W Lui; Oded Gonen
Journal:  NMR Biomed       Date:  2014-09-05       Impact factor: 4.044

10.  Magnetic Resonance Imaging of Phosphocreatine and Determination of BOLD Kinetics in Lower Extremity Muscles using a Dual-Frequency Coil Array.

Authors:  Ryan Brown; Oleksandr Khegai; Prodromos Parasoglou
Journal:  Sci Rep       Date:  2016-07-28       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.