Literature DB >> 1812380

Electromagnetic fields of surface coil in vivo NMR at high frequencies.

J R Keltner1, J W Carlson, M S Roos, S T Wong, T L Wong, T F Budinger.   

Abstract

A high frequency solution of the electromagnetic field produced by a circular surface coil adjacent to a homogeneous conducting, dielectric sphere is used to predict the attainable signal to noise ratio (S/N) and specific absorption rate (SAR) for in vivo 1H NMR spectroscopy experiments from 200 to 430 MHz (4.7-10 T). Above 200 MHz the S/N increases more rapidly with frequency and the SAR increases less rapidly compared with the respective S/N and SAR frequency dependence below 200 MHz. The difference in frequency dependence is due to dielectric resonances of the magnetic field inside the sphere at frequencies above 200 MHz. It is predicted that surface coil 1H NMR experiments may be performed on a head-sized sphere, having conductivity and relative dielectric constant of brain, at frequencies up to 430 MHz without exceeding 8 W/kg local SAR and 3.2 W/kg SAR. The calculations of the S/N and SAR are used to determine optimum surface coil geometries for NMR experiments. The power radiated by the surface coil in the absence of shielding and asymmetries in the received signal with respect to the plane defined by the surface coil axis and the direction of the static magnetic field are significant at high frequency. Experimental measurements of the magnetic field inside a head-sized sphere verify the presence of dielectric resonances at frequencies above 200 MHz.

Entities:  

Mesh:

Year:  1991        PMID: 1812380     DOI: 10.1002/mrm.1910220254

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  35 in total

1.  A 32-channel lattice transmission line array for parallel transmit and receive MRI at 7 tesla.

Authors:  Gregor Adriany; Edward J Auerbach; Carl J Snyder; Ark Gözübüyük; Steen Moeller; Johannes Ritter; Pierre-François Van de Moortele; Tommy Vaughan; Kâmil Uğurbil
Journal:  Magn Reson Med       Date:  2010-06       Impact factor: 4.668

2.  9.4T human MRI: preliminary results.

Authors:  Thomas Vaughan; Lance DelaBarre; Carl Snyder; Jinfeng Tian; Can Akgun; Devashish Shrivastava; Wanzahn Liu; Chris Olson; Gregor Adriany; John Strupp; Peter Andersen; Anand Gopinath; Pierre-Francois van de Moortele; Michael Garwood; Kamil Ugurbil
Journal:  Magn Reson Med       Date:  2006-12       Impact factor: 4.668

3.  Effects of coplanar shielding for high field MRI.

Authors:  Joseph V Rispoli; Matthew D Wilcox; Samantha By; Steven M Wright; Mary P McDougall
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2016-08

4.  Optimized quadrature surface coil designs.

Authors:  Ananda Kumar; Paul A Bottomley
Journal:  MAGMA       Date:  2007-12-04       Impact factor: 2.310

5.  Radiofrequency heating at 9.4T: in vivo temperature measurement results in swine.

Authors:  Devashish Shrivastava; Timothy Hanson; Robert Schlentz; William Gallaghar; Carl Snyder; Lance Delabarre; Surya Prakash; Paul Iaizzo; J Thomas Vaughan
Journal:  Magn Reson Med       Date:  2008-01       Impact factor: 4.668

6.  Local B1+ shimming for prostate imaging with transceiver arrays at 7T based on subject-dependent transmit phase measurements.

Authors:  Gregory J Metzger; Carl Snyder; Can Akgun; Tommy Vaughan; Kamil Ugurbil; Pierre-Francois Van de Moortele
Journal:  Magn Reson Med       Date:  2008-02       Impact factor: 4.668

7.  Spatial phase encoding exploiting the Bloch-Siegert shift effect.

Authors:  Ralf Kartäusch; Toni Driessle; Thomas Kampf; Thomas Christian Basse-Lüsebrink; Uvo Christoph Hoelscher; Peter Michael Jakob; Florian Fidler; Xavier Helluy
Journal:  MAGMA       Date:  2013-11-20       Impact factor: 2.310

8.  T1 weighted brain images at 7 Tesla unbiased for Proton Density, T2* contrast and RF coil receive B1 sensitivity with simultaneous vessel visualization.

Authors:  Pierre-François Van de Moortele; Edwards J Auerbach; Cheryl Olman; Essa Yacoub; Kâmil Uğurbil; Steen Moeller
Journal:  Neuroimage       Date:  2009-02-20       Impact factor: 6.556

9.  Mitigation of B1+ inhomogeneity using spatially selective excitation with jointly designed quadratic spatial encoding magnetic fields and RF shimming.

Authors:  Yi-Cheng Hsu; Riccardo Lattanzi; Ying-Hua Chu; Martijn A Cloos; Daniel K Sodickson; Fa-Hsuan Lin
Journal:  Magn Reson Med       Date:  2016-10-02       Impact factor: 4.668

Review 10.  Numerical field calculations considering the human subject for engineering and safety assurance in MRI.

Authors:  Christopher M Collins
Journal:  NMR Biomed       Date:  2009-11       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.