Transmit SENSE.

Ulrich Katscher1, Peter Börnert, Christoph Leussler, Johan S van den Brink.   

Abstract

The idea of using parallel imaging to shorten the acquisition time by the simultaneous use of multiple receive coils can be adapted for the parallel transmission of a spatially-selective multidimensional RF pulse. As in data acquisition, a multidimensional RF pulse follows a certain k-space trajectory. Shortening this trajectory shortens the pulse duration. The use of multiple transmit coils, each with its own time-dependent waveform and spatial sensitivity, can compensate for the missing parts of the excitation k-space. This results in a maintained spatial definition of the pulse profile, while its duration is reduced. This work introduces the concept of parallel transmission with arbitrarily shaped transmit coils (termed "Transmit SENSE"). Results of numerical studies demonstrate the theoretical feasibility of the approach. The experimental proof of principle is provided on a commercial MR scanner. The lack of multiple independent transmit channels was addressed by combining the excitation patterns from two separate subexperiments with different transmit setups. Shortening multidimensional RF pulses could be an interesting means of making 3D RF pulses feasible even for fast T(2)(*) relaxing species or strong main field inhomogeneities. Other applications might benefit from the ability of Transmit SENSE to improve the spatial resolution of the pulse profile while maintaining the transmit duration. Copyright 2003 Wiley-Liss, Inc.

Mesh:

Year:  2003        PMID: 12509830     DOI: 10.1002/mrm.10353

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  232 in total

1.  Current CONtrolled Transmit And Receive Coil Elements (CONTAR) for Parallel Acquisition and Parallel Excitation Techniques at High-Field MRI.

Authors:  E Kirilina; A Kühne; T Lindel; W Hoffmann; K H Rhein; T Riemer; F Seifert
Journal:  Appl Magn Reson       Date:  2011-08-21       Impact factor: 0.831

2.  Multislice ¹H MRSI of the human brain at 7 T using dynamic B₀ and B₁ shimming.

Authors:  Vincent O Boer; Dennis W J Klomp; Christoph Juchem; Peter R Luijten; Robin A de Graaf
Journal:  Magn Reson Med       Date:  2011-12-12       Impact factor: 4.668

3.  Reduced field-of-view excitation using second-order gradients and spatial-spectral radiofrequency pulses.

Authors:  Chao Ma; Dan Xu; Kevin F King; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2012-04-05       Impact factor: 4.668

4.  B1 mapping by Bloch-Siegert shift.

Authors:  Laura I Sacolick; Florian Wiesinger; Ileana Hancu; Mika W Vogel
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

Review 5.  In vivo structural imaging of the cerebellum, the contribution of ultra-high fields.

Authors:  José P Marques; Rolf Gruetter; Wietske van der Zwaag
Journal:  Cerebellum       Date:  2012-06       Impact factor: 3.847

6.  Experience with magnetic resonance imaging of human subjects with passive implants and tattoos at 7 T: a retrospective study.

Authors:  Yacine Noureddine; Andreas K Bitz; Mark E Ladd; Markus Thürling; Susanne C Ladd; Gregor Schaefers; Oliver Kraff
Journal:  MAGMA       Date:  2015-09-26       Impact factor: 2.310

Review 7.  Current trends and challenges in MRI acquisitions to investigate brain function.

Authors:  Bradley P Sutton; Cheng Ouyang; Dimitrios C Karampinos; Gregory A Miller
Journal:  Int J Psychophysiol       Date:  2009-02-21       Impact factor: 2.997

8.  T1 weighted brain images at 7 Tesla unbiased for Proton Density, T2* contrast and RF coil receive B1 sensitivity with simultaneous vessel visualization.

Authors:  Pierre-François Van de Moortele; Edwards J Auerbach; Cheryl Olman; Essa Yacoub; Kâmil Uğurbil; Steen Moeller
Journal:  Neuroimage       Date:  2009-02-20       Impact factor: 6.556

9.  Mitigation of B1+ inhomogeneity using spatially selective excitation with jointly designed quadratic spatial encoding magnetic fields and RF shimming.

Authors:  Yi-Cheng Hsu; Riccardo Lattanzi; Ying-Hua Chu; Martijn A Cloos; Daniel K Sodickson; Fa-Hsuan Lin
Journal:  Magn Reson Med       Date:  2016-10-02       Impact factor: 4.668

10.  Joint design of large-tip-angle parallel RF pulses and blipped gradient trajectories.

Authors:  Zhipeng Cao; Manus J Donahue; Jun Ma; William A Grissom
Journal:  Magn Reson Med       Date:  2015-04-27       Impact factor: 4.668