Literature DB >> 22311346

Simultaneous bilateral hip joint imaging at 7 Tesla using fast transmit B₁ shimming methods and multichannel transmission - a feasibility study.

J Ellermann1, U Goerke, P Morgan, K Ugurbil, J Tian, S Schmitter, T Vaughan, P-F Van De Moortele.   

Abstract

The objective of this study was to demonstrate the feasibility of simultaneous bilateral hip imaging at 7 Tesla. Hip joint MRI becomes clinically critical since recent advances have made hip arthroscopy an efficacious approach to treat a variety of early hip diseases. The success of these treatments requires a reliable and accurate diagnosis of intraarticular abnormalities at an early stage. Articular cartilage assessment is especially important to guide surgical decisions but is difficult to achieve with current MR methods. Because of gains in tissue contrast and spatial resolution reported at ultra high magnetic fields, there are strong expectations that imaging the hip joint at 7 Tesla will improve diagnostic accuracy. Furthermore, there is growing evidence that the majority of these hip abnormalities occur bilaterally, emphasizing the need for bilateral imaging. However, obtaining high quality images in the human torso, in particular of both hips simultaneously, must overcome a major challenge arising from the damped traveling wave behaviour of RF waves at 7 Tesla that leads to severe inhomogeneities in transmit B1 (B(1) (+) ) phase and magnitude, typically resulting in areas of low signal and contrast, and consequently impairing use for clinical applications. To overcome this problem, a 16-channel stripline transceiver RF coil was used, together with a B1 shimming algorithm aiming at maximizing B(1) (+) in six regions of interest over the hips that were identified on axial scout images. Our successful results demonstrate that this approach effectively reduces inhomogeneities observed before B1 shimming and provides high joint tissue contrast in both hips while reducing the required RF power. Critical to this success was a fast small flip angle B(1) (+) calibration scan that permitted the computation of subject-specific B1 shimming solutions, a necessary step to account for large spatial variations in B(1) (+) phase observed in different subjects.
Copyright © 2012 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22311346      PMCID: PMC3419302          DOI: 10.1002/nbm.2779

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  21 in total

1.  Analysis of wave behavior in lossy dielectric samples at high field.

Authors:  Qing X Yang; Jinghua Wang; Xiaoliang Zhang; Christopher M Collins; Michael B Smith; Haiying Liu; Xiao-Hong Zhu; J Thomas Vaughan; Kamil Ugurbil; Wei Chen
Journal:  Magn Reson Med       Date:  2002-05       Impact factor: 4.668

Review 2.  Potential and feasibility of parallel MRI at high field.

Authors:  Florian Wiesinger; Pierre-Francois Van de Moortele; Gregor Adriany; Nicola De Zanche; Kamil Ugurbil; Klaas P Pruessmann
Journal:  NMR Biomed       Date:  2006-05       Impact factor: 4.044

3.  Local B1+ shimming for prostate imaging with transceiver arrays at 7T based on subject-dependent transmit phase measurements.

Authors:  Gregory J Metzger; Carl Snyder; Can Akgun; Tommy Vaughan; Kamil Ugurbil; Pierre-Francois Van de Moortele
Journal:  Magn Reson Med       Date:  2008-02       Impact factor: 4.668

4.  Comparison of standard hip MR arthrographic imaging planes and sequences for detection of arthroscopically proven labral tear.

Authors:  Andrew J Ziegert; Donna G Blankenbaker; Arthur A De Smet; James S Keene; Kazuhiko Shinki; Jason P Fine
Journal:  AJR Am J Roentgenol       Date:  2009-05       Impact factor: 3.959

Review 5.  Magnetic resonance imaging of the hip at 3 Tesla: clinical value in femoroacetabular impingement of the hip and current concepts.

Authors:  Tallal Charles Mamisch; Bernd Bittersohl; Timothy Hughes; Young-Jo Kim; Goetz H Welsch; Marcel Dudda; Klaus A Siebenrock; Stefan Werlen; Siegfried Trattnig
Journal:  Semin Musculoskelet Radiol       Date:  2008-10-10       Impact factor: 1.777

6.  MRI of the wrist at 7 tesla using an eight-channel array coil combined with parallel imaging: preliminary results.

Authors:  Gregory Chang; Klaus M Friedrich; Ligong Wang; Renata L R Vieira; Mark E Schweitzer; Michael P Recht; Graham C Wiggins; Ravinder R Regatte
Journal:  J Magn Reson Imaging       Date:  2010-03       Impact factor: 4.813

7.  Fate of the normal uninvolved hip opposite closed reduction of unilateral developmental dislocation of the hip.

Authors:  Brian T Carney
Journal:  J Surg Orthop Adv       Date:  2006

8.  MR Arthrography of the Hip.

Authors:  William E. Palmer
Journal:  Semin Musculoskelet Radiol       Date:  1998       Impact factor: 1.777

9.  MRI of hip osteoarthritis and implications for surgery.

Authors:  Tallal C Mamisch; Christoph Zilkens; Klaus A Siebenrock; Bernd Bittersohl; Young-Jo Kim; Stefan Werlen
Journal:  Magn Reson Imaging Clin N Am       Date:  2010-02       Impact factor: 2.266

10.  Performance of external and internal coil configurations for prostate investigations at 7 T.

Authors:  Gregory J Metzger; Pierre-Francois van de Moortele; Can Akgun; Carl J Snyder; Steen Moeller; John Strupp; Peter Andersen; Devashish Shrivastava; Tommy Vaughan; Kamil Ugurbil; Gregor Adriany
Journal:  Magn Reson Med       Date:  2010-08-25       Impact factor: 4.668

View more
  20 in total

Review 1.  Magnetic resonance imaging at ultrahigh fields.

Authors:  Kamil Ugurbil
Journal:  IEEE Trans Biomed Eng       Date:  2014-03-25       Impact factor: 4.538

2.  7 Tesla quantitative hip MRI: T1, T2 and T2* mapping of hip cartilage in healthy volunteers.

Authors:  Andrea Lazik; Jens M Theysohn; Christina Geis; Sören Johst; Mark E Ladd; Harald H Quick; Oliver Kraff
Journal:  Eur Radiol       Date:  2015-08-28       Impact factor: 5.315

3.  MR imaging of the temporomandibular joint: comparison between acquisitions at 7.0 T using dielectric pads and 3.0 T.

Authors:  Felix P Kuhn; Georg Spinner; Filippo Del Grande; Michael Wyss; Marco Piccirelli; Stefan Erni; Pascal Pfister; Michael Ho; Bert-Ram Sah; Lukas Filli; Dominik A Ettlin; Luigi M Gallo; Gustav Andreisek; Andrei Manoliu
Journal:  Dentomaxillofac Radiol       Date:  2016-12-18       Impact factor: 2.419

4.  MRI of the hip at 7T: feasibility of bone microarchitecture, high-resolution cartilage, and clinical imaging.

Authors:  Gregory Chang; Cem M Deniz; Stephen Honig; Kenneth Egol; Ravinder R Regatte; Yudong Zhu; Daniel K Sodickson; Ryan Brown
Journal:  J Magn Reson Imaging       Date:  2013-09-23       Impact factor: 4.813

5.  Mitigating transmit B 1 inhomogeneity in the liver at 7T using multi-spoke parallel transmit RF pulse design.

Authors:  Xiaoping Wu; Sebastian Schmitter; Edward J Auerbach; Kâmil Uğurbil; Pierre-François Van de Moortele
Journal:  Quant Imaging Med Surg       Date:  2014-02

6.  First in-vivo human imaging at 10.5T: Imaging the body at 447 MHz.

Authors:  Xiaoxuan He; M Arcan Ertürk; Andrea Grant; Xiaoping Wu; Russell L Lagore; Lance DelaBarre; Yiğitcan Eryaman; Gregor Adriany; Eddie J Auerbach; Pierre-François Van de Moortele; Kâmil Uğurbil; Gregory J Metzger
Journal:  Magn Reson Med       Date:  2019-12-17       Impact factor: 4.668

7.  Design and application of combined 8-channel transmit and 10-channel receive arrays and radiofrequency shimming for 7-T shoulder magnetic resonance imaging.

Authors:  Ryan Brown; Cem Murat Deniz; Bei Zhang; Gregory Chang; Daniel K Sodickson; Graham C Wiggins
Journal:  Invest Radiol       Date:  2014-01       Impact factor: 6.016

8.  Morphological imaging and T2 and T2* mapping of hip cartilage at 7 Tesla MRI under the influence of intravenous gadolinium.

Authors:  Andrea Lazik-Palm; Oliver Kraff; Christina Geis; Sören Johst; Juliane Goebel; Mark E Ladd; Harald H Quick; Jens M Theysohn
Journal:  Eur Radiol       Date:  2016-02-12       Impact factor: 5.315

9.  Bilateral hip imaging at 7 Tesla using a multi-channel transmit technology: initial results presenting anatomical detail in healthy volunteers and pathological changes in patients with avascular necrosis of the femoral head.

Authors:  J M Theysohn; O Kraff; S Orzada; N Theysohn; T Classen; S Landgraeber; M E Ladd; T C Lauenstein
Journal:  Skeletal Radiol       Date:  2013-08-18       Impact factor: 2.199

10.  Spin echo functional MRI in bilateral auditory cortices at 7 T: an application of B₁ shimming.

Authors:  Federico De Martino; Sebastian Schmitter; Michelle Moerel; Jinfeng Tian; Kamil Ugurbil; Elia Formisano; Essa Yacoub; Pierre-Francois van de Moortele
Journal:  Neuroimage       Date:  2012-08-21       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.