Literature DB >> 11979578

Analysis of wave behavior in lossy dielectric samples at high field.

Qing X Yang1, Jinghua Wang, Xiaoliang Zhang, Christopher M Collins, Michael B Smith, Haiying Liu, Xiao-Hong Zhu, J Thomas Vaughan, Kamil Ugurbil, Wei Chen.   

Abstract

Radiofrequency (RF) field wave behavior and associated nonuniform image intensity at high magnetic field strengths are examined experimentally and numerically. The RF field produced by a 10-cm-diameter surface coil at 300 MHz is evaluated in a 16-cm-diameter spherical phantom with variable salinity, and in the human head. Temporal progression of the RF field indicates that the standing wave and associated dielectric resonance occurring in a pure water phantom near 300 MHz is greatly dampened in the human head due to the strong decay of the electromagnetic wave. The characteristic image intensity distribution in the human head is the result of spatial phase distribution and amplitude modulation by the interference of the RF traveling waves determined by a given sample-coil configuration. The numerical calculation method is validated with experimental results. The general behavior of the RF field with respect to the average brain electrical properties in a frequency range of 42-350 MHz is also analyzed. Copyright 2002 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2002        PMID: 11979578     DOI: 10.1002/mrm.10137

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  78 in total

1.  K-space reconstruction with anisotropic kernel support (KARAOKE) for ultrafast partially parallel imaging.

Authors:  Jun Miao; Wilbur C K Wong; Sreenath Narayan; David L Wilson
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

2.  Ultra-high-field magnetic resonance: Why and when?

Authors:  Ewald Moser
Journal:  World J Radiol       Date:  2010-01-28

Review 3.  Magnetic resonance imaging at ultrahigh fields.

Authors:  Kamil Ugurbil
Journal:  IEEE Trans Biomed Eng       Date:  2014-03-25       Impact factor: 4.538

4.  Small tip angle three-dimensional tailored radiofrequency slab-select pulse for reduced B1 inhomogeneity at 3 T.

Authors:  Suwit Saekho; Fernando E Boada; Douglas C Noll; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

5.  9.4T human MRI: preliminary results.

Authors:  Thomas Vaughan; Lance DelaBarre; Carl Snyder; Jinfeng Tian; Can Akgun; Devashish Shrivastava; Wanzahn Liu; Chris Olson; Gregor Adriany; John Strupp; Peter Andersen; Anand Gopinath; Pierre-Francois van de Moortele; Michael Garwood; Kamil Ugurbil
Journal:  Magn Reson Med       Date:  2006-12       Impact factor: 4.668

6.  Simultaneous bilateral hip joint imaging at 7 Tesla using fast transmit B₁ shimming methods and multichannel transmission - a feasibility study.

Authors:  J Ellermann; U Goerke; P Morgan; K Ugurbil; J Tian; S Schmitter; T Vaughan; P-F Van De Moortele
Journal:  NMR Biomed       Date:  2012-02-07       Impact factor: 4.044

7.  Reduction of transmitter B1 inhomogeneity with transmit SENSE slice-select pulses.

Authors:  Zhenghui Zhang; Chun-Yu Yip; William Grissom; Douglas C Noll; Fernando E Boada; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2007-05       Impact factor: 4.668

8.  Diffusion-weighted radial fast spin-echo for high-resolution diffusion tensor imaging at 3T.

Authors:  Joelle E Sarlls; Carlo Pierpaoli
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

Review 9.  Numerical field calculations considering the human subject for engineering and safety assurance in MRI.

Authors:  Christopher M Collins
Journal:  NMR Biomed       Date:  2009-11       Impact factor: 4.044

10.  Precompensation for mutual coupling between array elements in parallel excitation.

Authors:  Yong Pang; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2011-12
View more