Literature DB >> 20512850

A 32-channel lattice transmission line array for parallel transmit and receive MRI at 7 tesla.

Gregor Adriany1, Edward J Auerbach, Carl J Snyder, Ark Gözübüyük, Steen Moeller, Johannes Ritter, Pierre-François Van de Moortele, Tommy Vaughan, Kâmil Uğurbil.   

Abstract

Transmit and receive RF coil arrays have proven to be particularly beneficial for ultra-high-field MR. Transmit coil arrays enable such techniques as B(1) (+) shimming to substantially improve transmit B(1) homogeneity compared to conventional volume coil designs, and receive coil arrays offer enhanced parallel imaging performance and SNR. Concentric coil arrangements hold promise for developing transceiver arrays incorporating large numbers of coil elements. At magnetic field strengths of 7 tesla and higher where the Larmor frequencies of interest can exceed 300 MHz, the coil array design must also overcome the problem of the coil conductor length approaching the RF wavelength. In this study, a novel concentric arrangement of resonance elements built from capacitively-shortened half-wavelength transmission lines is presented. This approach was utilized to construct an array with whole-brain coverage using 16 transceiver elements and 16 receive-only elements, resulting in a coil with a total of 16 transmit and 32 receive channels. (c) 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20512850      PMCID: PMC2946833          DOI: 10.1002/mrm.22413

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  17 in total

Review 1.  Functional mapping in the human brain using high magnetic fields.

Authors:  K Uğurbil; X Hu; W Chen; X H Zhu; S G Kim; A Georgopoulos
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  1999-07-29       Impact factor: 6.237

2.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

3.  Microstrip RF surface coil design for extremely high-field MRI and spectroscopy.

Authors:  X Zhang; K Ugurbil; W Chen
Journal:  Magn Reson Med       Date:  2001-09       Impact factor: 4.668

4.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

5.  Transmit and receive transmission line arrays for 7 Tesla parallel imaging.

Authors:  Gregor Adriany; Pierre-Francois Van de Moortele; Florian Wiesinger; Steen Moeller; John P Strupp; Peter Andersen; Carl Snyder; Xiaoliang Zhang; Wei Chen; Klaas P Pruessmann; Peter Boesiger; Tommy Vaughan; Kāmil Uğurbil
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

6.  Concentric coil arrays for parallel MRI.

Authors:  Michael A Ohliger; Robert L Greenman; Randy Giaquinto; Charles A McKenzie; Graham Wiggins; Daniel K Sodickson
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

7.  Parallel imaging performance as a function of field strength--an experimental investigation using electrodynamic scaling.

Authors:  Florian Wiesinger; Pierre-Francois Van de Moortele; Gregor Adriany; Nicola De Zanche; Kamil Ugurbil; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2004-11       Impact factor: 4.668

8.  Electromagnetic fields of surface coil in vivo NMR at high frequencies.

Authors:  J R Keltner; J W Carlson; M S Roos; S T Wong; T L Wong; T F Budinger
Journal:  Magn Reson Med       Date:  1991-12       Impact factor: 4.668

9.  Steady-state cerebral glucose concentrations and transport in the human brain.

Authors:  R Gruetter; K Ugurbil; E R Seaquist
Journal:  J Neurochem       Date:  1998-01       Impact factor: 5.372

10.  The field dependence of NMR imaging. I. Laboratory assessment of signal-to-noise ratio and power deposition.

Authors:  C N Chen; V J Sank; S M Cohen; D I Hoult
Journal:  Magn Reson Med       Date:  1986-10       Impact factor: 4.668

View more
  28 in total

Review 1.  RF pulse methods for use with surface coils: Frequency-modulated pulses and parallel transmission.

Authors:  Michael Garwood; Kamil Uğurbil
Journal:  J Magn Reson       Date:  2018-04-26       Impact factor: 2.229

2.  SAR reduction in 7T C-spine imaging using a "dark modes" transmit array strategy.

Authors:  Yigitcan Eryaman; Bastien Guerin; Boris Keil; Azma Mareyam; Joaquin L Herraiz; Robert K Kosior; Adrian Martin; Angel Torrado-Carvajal; Norberto Malpica; Juan A Hernandez-Tamames; Emanuele Schiavi; Elfar Adalsteinsson; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2014-04-18       Impact factor: 4.668

3.  Evaluation of a 16-channel transceiver loop + dipole antenna array for human head imaging at 10.5 tesla.

Authors:  Myung Kyun Woo; Lance DelaBarre; Byeong-Yeul Lee; Matt Waks; Russell Luke Lagore; Jerahmie Radder; Yigitcan Eryaman; Kamil Ugurbil; Gregor Adriany
Journal:  IEEE Access       Date:  2020-11-06       Impact factor: 3.367

4.  Parallel imaging performance investigation of an 8-channel common-mode differential-mode (CMDM) planar array for 7T MRI.

Authors:  Xiaoqing Hu; Xiao Chen; Xin Liu; Hairong Zheng; Ye Li; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-02

5.  A dual-tuned quadrature volume coil with mixed λ/2 and λ/4 microstrip resonators for multinuclear MRSI at 7 T.

Authors:  Yong Pang; Zhentian Xie; Duan Xu; Douglas A Kelley; Sarah J Nelson; Daniel B Vigneron; Xiaoliang Zhang
Journal:  Magn Reson Imaging       Date:  2011-11-03       Impact factor: 2.546

6.  Improving radiofrequency power and specific absorption rate management with bumped transmit elements in ultra-high field MRI.

Authors:  Alireza Sadeghi-Tarakameh; Gregor Adriany; Gregory J Metzger; Russell L Lagore; Steve Jungst; Lance DelaBarre; Pierre-Francois Van de Moortele; Kamil Ugurbil; Ergin Atalar; Yigitcan Eryaman
Journal:  Magn Reson Med       Date:  2020-06-23       Impact factor: 4.668

Review 7.  Imaging at ultrahigh magnetic fields: History, challenges, and solutions.

Authors:  Kamil Uğurbil
Journal:  Neuroimage       Date:  2017-07-08       Impact factor: 6.556

Review 8.  Massively parallel MRI detector arrays.

Authors:  Boris Keil; Lawrence L Wald
Journal:  J Magn Reson       Date:  2013-02-07       Impact factor: 2.229

9.  Resonant inductive decoupling (RID) for transceiver arrays to compensate for both reactive and resistive components of the mutual impedance.

Authors:  Nikolai I Avdievich; Jullie W Pan; Hoby P Hetherington
Journal:  NMR Biomed       Date:  2013-06-18       Impact factor: 4.044

10.  Nineteen-channel receive array and four-channel transmit array coil for cervical spinal cord imaging at 7T.

Authors:  Wei Zhao; Julien Cohen-Adad; Jonathan R Polimeni; Boris Keil; Bastien Guerin; Kawin Setsompop; Peter Serano; Azma Mareyam; Philipp Hoecht; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2013-08-20       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.