Literature DB >> 17075852

9.4T human MRI: preliminary results.

Thomas Vaughan1, Lance DelaBarre, Carl Snyder, Jinfeng Tian, Can Akgun, Devashish Shrivastava, Wanzahn Liu, Chris Olson, Gregor Adriany, John Strupp, Peter Andersen, Anand Gopinath, Pierre-Francois van de Moortele, Michael Garwood, Kamil Ugurbil.   

Abstract

This work reports the preliminary results of the first human images at the new high-field benchmark of 9.4T. A 65-cm-diameter bore magnet was used together with an asymmetric 40-cm-diameter head gradient and shim set. A multichannel transmission line (transverse electromagnetic (TEM)) head coil was driven by a programmable parallel transceiver to control the relative phase and magnitude of each channel independently. These new RF field control methods facilitated compensation for RF artifacts attributed to destructive interference patterns, in order to achieve homogeneous 9.4T head images or localize anatomic targets. Prior to FDA investigational device exemptions (IDEs) and internal review board (IRB)-approved human studies, preliminary RF safety studies were performed on porcine models. These data are reported together with exit interview results from the first 44 human volunteers. Although several points for improvement are discussed, the preliminary results demonstrate the feasibility of safe and successful human imaging at 9.4T.

Entities:  

Mesh:

Year:  2006        PMID: 17075852      PMCID: PMC4406343          DOI: 10.1002/mrm.21073

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  16 in total

Review 1.  Sensitivity and power deposition in a high-field imaging experiment.

Authors:  D I Hoult; D Phil
Journal:  J Magn Reson Imaging       Date:  2000-07       Impact factor: 4.813

2.  Subchronic in vivo effects of a high static magnetic field (9.4 T) in rats.

Authors:  W B High; J Sikora; K Ugurbil; M Garwood
Journal:  J Magn Reson Imaging       Date:  2000-07       Impact factor: 4.813

3.  7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images.

Authors:  J T Vaughan; M Garwood; C M Collins; W Liu; L DelaBarre; G Adriany; P Andersen; H Merkle; R Goebel; M B Smith; K Ugurbil
Journal:  Magn Reson Med       Date:  2001-07       Impact factor: 4.668

4.  Analysis of wave behavior in lossy dielectric samples at high field.

Authors:  Qing X Yang; Jinghua Wang; Xiaoliang Zhang; Christopher M Collins; Michael B Smith; Haiying Liu; Xiao-Hong Zhu; J Thomas Vaughan; Kamil Ugurbil; Wei Chen
Journal:  Magn Reson Med       Date:  2002-05       Impact factor: 4.668

5.  Dielectric resonances and B(1) field inhomogeneity in UHFMRI: computational analysis and experimental findings.

Authors:  T S Ibrahim; R Lee; A M Abduljalil; B A Baertlein; P M Robitaille
Journal:  Magn Reson Imaging       Date:  2001-02       Impact factor: 2.546

6.  Efficient high-frequency body coil for high-field MRI.

Authors:  J T Vaughan; G Adriany; C J Snyder; J Tian; T Thiel; L Bolinger; H Liu; L DelaBarre; K Ugurbil
Journal:  Magn Reson Med       Date:  2004-10       Impact factor: 4.668

7.  Transmit and receive transmission line arrays for 7 Tesla parallel imaging.

Authors:  Gregor Adriany; Pierre-Francois Van de Moortele; Florian Wiesinger; Steen Moeller; John P Strupp; Peter Andersen; Carl Snyder; Xiaoliang Zhang; Wei Chen; Klaas P Pruessmann; Peter Boesiger; Tommy Vaughan; Kāmil Uğurbil
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

8.  Electromagnetic fields of surface coil in vivo NMR at high frequencies.

Authors:  J R Keltner; J W Carlson; M S Roos; S T Wong; T L Wong; T F Budinger
Journal:  Magn Reson Med       Date:  1991-12       Impact factor: 4.668

9.  SAR and B1 field distributions in a heterogeneous human head model within a birdcage coil. Specific energy absorption rate.

Authors:  C M Collins; S Li; M B Smith
Journal:  Magn Reson Med       Date:  1998-12       Impact factor: 4.668

10.  Spectroscopy and imaging with a 4 tesla whole-body MR system.

Authors:  H Bomsdorf; T Helzel; D Kunz; P Röschmann; O Tschendel; J Wieland
Journal:  NMR Biomed       Date:  1988-06       Impact factor: 4.044

View more
  81 in total

1.  Design of an Electrically Automated RF Transceiver Head Coil in MRI.

Authors:  Sung-Min Sohn; Lance DelaBarre; Anand Gopinath; John Thomas Vaughan
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2014-10-28       Impact factor: 3.833

Review 2.  Magnetic resonance imaging at ultrahigh fields.

Authors:  Kamil Ugurbil
Journal:  IEEE Trans Biomed Eng       Date:  2014-03-25       Impact factor: 4.538

3.  High-field MRI of brain cortical substructure based on signal phase.

Authors:  Jeff H Duyn; Peter van Gelderen; Tie-Qiang Li; Jacco A de Zwart; Alan P Koretsky; Masaki Fukunaga
Journal:  Proc Natl Acad Sci U S A       Date:  2007-06-22       Impact factor: 11.205

4.  Radiofrequency heating at 9.4T: in vivo temperature measurement results in swine.

Authors:  Devashish Shrivastava; Timothy Hanson; Robert Schlentz; William Gallaghar; Carl Snyder; Lance Delabarre; Surya Prakash; Paul Iaizzo; J Thomas Vaughan
Journal:  Magn Reson Med       Date:  2008-01       Impact factor: 4.668

Review 5.  Magnetic nanoparticles for MR imaging: agents, techniques and cardiovascular applications.

Authors:  David E Sosnovik; Matthias Nahrendorf; Ralph Weissleder
Journal:  Basic Res Cardiol       Date:  2008-03       Impact factor: 17.165

6.  Ultra-high field parallel imaging of the superior parietal lobule during mental maze solving.

Authors:  Trenton A Jerde; Scott M Lewis; Ute Goerke; Pavlos Gourtzelidis; Charidimos Tzagarakis; Joshua Lynch; Steen Moeller; Pierre-François Van de Moortele; Gregor Adriany; Jeran Trangle; Kâmil Uğurbil; Apostolos P Georgopoulos
Journal:  Exp Brain Res       Date:  2008-02-28       Impact factor: 1.972

7.  Influence of molecular parameters and increasing magnetic field strength on relaxivity of gadolinium- and manganese-based T1 contrast agents.

Authors:  Peter Caravan; Christian T Farrar; Luca Frullano; Ritika Uppal
Journal:  Contrast Media Mol Imaging       Date:  2009 Mar-Apr       Impact factor: 3.161

8.  Mitigation of B1+ inhomogeneity using spatially selective excitation with jointly designed quadratic spatial encoding magnetic fields and RF shimming.

Authors:  Yi-Cheng Hsu; Riccardo Lattanzi; Ying-Hua Chu; Martijn A Cloos; Daniel K Sodickson; Fa-Hsuan Lin
Journal:  Magn Reson Med       Date:  2016-10-02       Impact factor: 4.668

Review 9.  Numerical field calculations considering the human subject for engineering and safety assurance in MRI.

Authors:  Christopher M Collins
Journal:  NMR Biomed       Date:  2009-11       Impact factor: 4.044

Review 10.  Toward 20 T magnetic resonance for human brain studies: opportunities for discovery and neuroscience rationale.

Authors:  Thomas F Budinger; Mark D Bird; Lucio Frydman; Joanna R Long; Thomas H Mareci; William D Rooney; Bruce Rosen; John F Schenck; Victor D Schepkin; A Dean Sherry; Daniel K Sodickson; Charles S Springer; Keith R Thulborn; Kamil Uğurbil; Lawrence L Wald
Journal:  MAGMA       Date:  2016-05-18       Impact factor: 2.310

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.