Literature DB >> 1797894

The accuracy of the Biox 3700 pulse oximeter in patients receiving vasoactive therapy.

J Ibáñez1, J Velasco, J M Raurich.   

Abstract

The accuracy of pulse oximetry for the prediction of oxygen saturation of arterial blood in patients with shock has been hardly studied. This study was undertaken to determine if O2 arterial saturation estimated by the Biox 3700 pulse oximeter (SpO2) with an ear probe could reliably substitute for the measurements of O2 saturation (HbO2) with an IL-282 Co-Oximeter in samples of arterial blood obtained from 24 caucasian patients. All patients were mechanically ventilated and needed vasoactive drugs (dopamine and/or dobutamine). Of 24 patients 13 had shock: cardiogenic (n = 6) and septic (n = 7). The mean difference between HbO2 and SpO2 was 2.49% +/- 4.24, with a 95% confidence interval of 0.7% to 4.3% (p = 0.009). There were clinically important differences between both methods since in 9 of 24 patients (37%) SpO2 values were at least 4% lower or greater than HbO2. This disagreement was also apparent in patients with (6/13, 46%) or without shock (3/11, 27%). To conclude, pulse oximetry is not always a sufficiently reliable method to predict HbO2 in patients with or without shock treated with vasoactive drugs.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1797894     DOI: 10.1007/BF01690773

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


  14 in total

1.  Comparison of pulse oximeters: effects of vasoconstriction and venous engorgement.

Authors:  C J Wilkins; M Moores; C D Hanning
Journal:  Br J Anaesth       Date:  1989-04       Impact factor: 9.166

2.  Oximetry--know thy limits.

Authors:  A L Ries
Journal:  Chest       Date:  1987-03       Impact factor: 9.410

3.  Range of accuracy of two wavelength oximetry.

Authors:  K R Chapman; F L Liu; R M Watson; A S Rebuck
Journal:  Chest       Date:  1986-04       Impact factor: 9.410

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Pulse oximeter failure thresholds in hypotension and vasoconstriction.

Authors:  J W Severinghaus; M J Spellman
Journal:  Anesthesiology       Date:  1990-09       Impact factor: 7.892

6.  Clinical evaluation of a new finger oximeter.

Authors:  S K Kim; B S Baidwan; T L Petty
Journal:  Crit Care Med       Date:  1984-10       Impact factor: 7.598

7.  The accuracy and response characteristics of a simplified ear oximeter.

Authors:  K R Chapman; A D'Urzo; A S Rebuck
Journal:  Chest       Date:  1983-06       Impact factor: 9.410

8.  Accuracy of response of six pulse oximeters to profound hypoxia.

Authors:  J W Severinghaus; K H Naifeh
Journal:  Anesthesiology       Date:  1987-10       Impact factor: 7.892

9.  Evaluation of the Ohmeda 3700 pulse oximeter: steady-state and transient response characteristics.

Authors:  D M Kagle; C M Alexander; R S Berko; M Giuffre; J B Gross
Journal:  Anesthesiology       Date:  1987-03       Impact factor: 7.892

10.  Accuracy of two ear oximeters at rest and during exercise in pulmonary patients.

Authors:  A L Ries; J T Farrow; J L Clausen
Journal:  Am Rev Respir Dis       Date:  1985-09
View more
  11 in total

1.  Decreased accuracy of pulse oximetry measurements during low perfusion caused by sepsis: Is the perfusion index of any value?

Authors:  Helmut D Hummler; Anja Engelmann; Frank Pohlandt; Josef Högel; Axel R Franz
Journal:  Intensive Care Med       Date:  2006-06-30       Impact factor: 17.440

2.  Pulse oximetry and high-dose vasopressors: a comparison between forehead reflectance and finger transmission sensors.

Authors:  Nicolas Nesseler; Jean-Vincent Frénel; Yoann Launey; Jeff Morcet; Yannick Mallédant; Philippe Seguin
Journal:  Intensive Care Med       Date:  2012-08-07       Impact factor: 17.440

3.  The accuracy of pulse oximetry in emergency department patients with severe sepsis and septic shock: a retrospective cohort study.

Authors:  Ben J Wilson; Hamish J Cowan; Jason A Lord; Dan J Zuege; David A Zygun
Journal:  BMC Emerg Med       Date:  2010-05-05

4.  Accuracy of pulse oximetry readings in an animal model of low perfusion caused by emerging pneumonia and sepsis.

Authors:  Helmut D Hummler; Anja Engelmann; Frank Pohlandt; Josef Högel; Axel R Franz
Journal:  Intensive Care Med       Date:  2004-01-13       Impact factor: 17.440

5.  Donor preoperative oxygen delivery and post-extubation hypoxia impact donation after circulatory death hypoxic cholangiopathy.

Authors:  Thomas J Chirichella; C Michael Dunham; Michael A Zimmerman; Elise M Phelan; M Susan Mandell; Kendra D Conzen; Stephen E Kelley; Trevor L Nydam; Thomas E Bak; Igal Kam; Michael E Wachs
Journal:  World J Gastroenterol       Date:  2016-03-28       Impact factor: 5.742

6.  Pulse Oximetry and Arterial Oxygen Saturation during Cardiopulmonary Exercise Testing.

Authors:  Mona Ascha; Anirban Bhattacharyya; Jose A Ramos; Adriano R Tonelli
Journal:  Med Sci Sports Exerc       Date:  2018-10       Impact factor: 5.411

7.  Determining a target SpO2 to maintain PaO2 within a physiological range.

Authors:  Jantine G Röttgering; Angelique M E de Man; Thomas C Schuurs; Evert-Jan Wils; Johannes M Daniels; Joost G van den Aardweg; Armand R J Girbes; Yvo M Smulders
Journal:  PLoS One       Date:  2021-05-13       Impact factor: 3.240

8.  Pulse oximetry.

Authors: 
Journal:  Crit Care       Date:  1999       Impact factor: 9.097

9.  Do changes in pulse oximeter oxygen saturation predict equivalent changes in arterial oxygen saturation?

Authors:  Gavin D Perkins; Daniel F McAuley; Simon Giles; Helen Routledge; Fang Gao
Journal:  Crit Care       Date:  2003-06-11       Impact factor: 9.097

10.  Accuracy of pulse oximetry in detection of oxygen saturation in patients admitted to the intensive care unit of heart surgery: comparison of finger, toe, forehead and earlobe probes.

Authors:  Sohila Seifi; Alireza Khatony; Gholamreza Moradi; Alireza Abdi; Farid Najafi
Journal:  BMC Nurs       Date:  2018-04-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.