Pulse oximeter failure thresholds in hypotension and vasoconstriction.

J W Severinghaus1, M J Spellman.   

Abstract

The degree of systolic hypotension causing failure and recovery were tested simultaneously with three oximeters (CSI 504US, Nellcor N-200, and Ohmeda 3740) in nine normal male volunteers. Perfusion of the right hand was slowly reduced and restored by 1) elevation of the hand plus systemic hypotension with nitroprusside if needed (EL); 2) clamp compression of the brachial artery (CL); 3) brachial cuff inflation (CU); and 4) intraarterial norepinephrine (NE). With EL, pulse pressure was normal whereas right radial arterial systolic pressure (SP) was 25.3 +/- 12.4 mmHg at failure and 34.1 +/- 13.3 at recovery (mean of three oximeters, n = 189). With CL, pulse pressure fell more than did mean pressure, and failure occurred at 37.3 +/- 9.8 and recovery at 46.8 +/- 17.6 mmHg, n = 84. With CL, threshold of function, defined as the average of failure SP and recovery SP, was 47.1 +/- 13.5, n = 41 for Nellcor, higher than for either CSI (38.7 +/- 14.5, n = 17) or Ohmeda (36.0 +/- 3.4, n = 26) (P less than 0.05). With EL, no difference among instruments was found (mean 29.7 +/- 12.8, n = 189). Threshold was 58.2 +/- 8.4, n = 17 with CU if cuff inflation was slow (filling veins), but recovery was similar to EL after rapid cuff occlusion. With NE, SP threshold was increased to 58.3 +/- 21.0 with CL but only to 41.0 +/- 13.8 with EL.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1990        PMID: 2393137     DOI: 10.1097/00000542-199009000-00025

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  15 in total

1.  Arterial line for monitoring SpO2 in patients with ischemic peripheries.

Authors:  Goneppanavar Umesh; Kaur Jasvinder; Shetty Nanda; Shetty Ranjan
Journal:  J Clin Monit Comput       Date:  2010-07-16       Impact factor: 2.502

2.  The influence of larger subcutaneous blood vessels on pulse oximetry.

Authors:  Paul D Mannheimer; Neil Michael P O'; Ewald Konecny
Journal:  J Clin Monit Comput       Date:  2004-06       Impact factor: 2.502

3.  Decreased accuracy of pulse oximetry measurements during low perfusion caused by sepsis: Is the perfusion index of any value?

Authors:  Helmut D Hummler; Anja Engelmann; Frank Pohlandt; Josef Högel; Axel R Franz
Journal:  Intensive Care Med       Date:  2006-06-30       Impact factor: 17.440

Review 4.  Pulse oximetry and capnography in intensive and transitional care units.

Authors:  F Bongard; D Sue
Journal:  West J Med       Date:  1992-01

5.  The effects of gel-based manicure on pulse oximetry.

Authors:  Jia Lin Jacklyn Yek; Hairil Rizal Abdullah; June Pheck Suan Goh; Yew Weng Chan
Journal:  Singapore Med J       Date:  2019-03-11       Impact factor: 1.858

6.  Anesthetic and analgesic effects of an opioid-free, injectable protocol in cats undergoing ovariohysterectomy: A prospective, blinded, randomized clinical trial.

Authors:  Truc Ngoc Diep; Beatriz P Monteiro; Marina C Evangelista; Aurelien Balleydier; Ryota Watanabe; Hélène L M Ruel; Graeme M Doodnaught; Thong Le Quang; Paulo V Steagall
Journal:  Can Vet J       Date:  2020-06       Impact factor: 1.008

7.  Pulse oximeter signal at various blood flow conditions in an in vitro model.

Authors:  L G Lindberg; M Vegfors; C Lennmarken; P A Oberg
Journal:  Med Biol Eng Comput       Date:  1995-01       Impact factor: 2.602

8.  Pulse oximetry in an extensively burned patient.

Authors:  H Imaizumi; Y Ujike; S Sumita; M Kaneko
Journal:  J Clin Monit       Date:  1995-01

9.  Failure rate of pulse oximetry in the postanesthesia care unit.

Authors:  B S Gillies; K Posner; P Freund; F Cheney
Journal:  J Clin Monit       Date:  1993-11

10.  The accuracy of the Biox 3700 pulse oximeter in patients receiving vasoactive therapy.

Authors:  J Ibáñez; J Velasco; J M Raurich
Journal:  Intensive Care Med       Date:  1991       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.