Literature DB >> 3956279

Range of accuracy of two wavelength oximetry.

K R Chapman, F L Liu, R M Watson, A S Rebuck.   

Abstract

Earlier reports of a two wavelength oximeter suggested a tendency toward overestimation of arterial oxygen saturation (SaO2) at the lowest values examined. To investigate this possible inaccuracy, we compared oximeter readings to SaO2 over a wider range of laboratory-induced steady-state hypoxia than has previously been reported. For values of SaO2 greater than 75 percent, oximeter readings were linearly related to SaO2 such that y = 0.94 SaO2 + 8.7 (r = 0.96) and the mean difference between oximeter reading and SaO2 was 0.09 percent. However, when SaO2 was less than 75 percent, the instrument readings were progressively higher than the SaO2 so that when SaO2 was approximately 50 percent, the oximeter reading was approximately 65 percent. These data show that the two wavelength oximeter displays falsely elevated readings when the arterial saturation falls below 75 percent.

Entities:  

Mesh:

Year:  1986        PMID: 3956279     DOI: 10.1378/chest.89.4.540

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  14 in total

1.  Cigarette smoking behavior and respiratory alterations during sleep in a healthy population.

Authors:  Gonzalo G Casasola; José L Alvarez-Sala; José A Marques; José M F Sánchez-Alarcos; Donald P Tashkin; Domingo Espinós
Journal:  Sleep Breath       Date:  2002-03       Impact factor: 2.816

Review 2.  How much polysomnography is enough?

Authors:  D Kurtz
Journal:  Lung       Date:  1990       Impact factor: 2.584

Review 3.  Pulse oximetry.

Authors:  J F Kelleher
Journal:  J Clin Monit       Date:  1989-01

Review 4.  Pulse oximetry and capnography in intensive and transitional care units.

Authors:  F Bongard; D Sue
Journal:  West J Med       Date:  1992-01

Review 5.  Pulse oximetry for hypoxemia: a warning to users and manufacturers.

Authors:  S Fanconi
Journal:  Intensive Care Med       Date:  1989       Impact factor: 17.440

6.  Pulse oximetry: a "which" hunt?

Authors:  M K Sykes
Journal:  J Clin Monit       Date:  1989-04

7.  Evaluation of the Ohmeda 3700 pulse oximeter.

Authors:  A R Warley; J H Mitchell; J R Stradling
Journal:  Thorax       Date:  1987-11       Impact factor: 9.139

8.  Errors in 14 pulse oximeters during profound hypoxia.

Authors:  J W Severinghaus; K H Naifeh; S O Koh
Journal:  J Clin Monit       Date:  1989-04

9.  Pulse oximetry in sickle cell disease.

Authors:  P Pianosi; T D Charge; D W Esseltine; A L Coates
Journal:  Arch Dis Child       Date:  1993-06       Impact factor: 3.791

10.  The accuracy of the Biox 3700 pulse oximeter in patients receiving vasoactive therapy.

Authors:  J Ibáñez; J Velasco; J M Raurich
Journal:  Intensive Care Med       Date:  1991       Impact factor: 17.440

View more