Literature DB >> 17899236

Range of motion measurement of an artificial hip joint using CT images.

Haosheng Sun1, Hidenori Inaoka, Yutaka Fukuoka, Tadashi Masuda, Akimasa Ishida, Sadao Morita.   

Abstract

Total hip arthroplasty (THA) is one of the most effective treatments for osteoarthritis and rheumatoid arthritis. Dislocation of the femoral head from the acetabular socket is a major problem of THA. To prevent dislocation, it is important to know the range of motion (ROM) after THA. Although various studies on the ROM were carried out, there exist only a few reports on ROM evaluation in individual patients. This is because in clinical cases, bone-to-bone and bone-to-component contacts must be considered besides the impingement of components. In this study, a new method for evaluating ROM of internal/external rotation, which takes into account all combinations of contacts between the bones and components, was proposed. A computer simulation demonstrated that the RMS error of the proposed method was approximately 3 degrees . The method was applied to 33 THAs under various conditions of flexion and adduction angles. The method was able to detect any type of impingement. The evaluated ROM was in good agreement with that measured during the THA operation (correlation coefficient = 0.91).

Entities:  

Mesh:

Year:  2007        PMID: 17899236     DOI: 10.1007/s11517-007-0258-y

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  16 in total

1.  The effect of acetabular cup orientations on limiting hip rotation.

Authors:  F J Kummer; S Shah; S Iyer; P E DiCesare
Journal:  J Arthroplasty       Date:  1999-06       Impact factor: 4.757

Review 2.  Computer simulation: how can it help the surgeon optimize implant position?

Authors:  Philip C Noble; Nobuhiko Sugano; James D Johnston; Matthew T Thompson; Michael A Conditt; Charles A Engh; Kenneth B Mathis
Journal:  Clin Orthop Relat Res       Date:  2003-12       Impact factor: 4.176

3.  Compliant positioning of total hip components for optimal range of motion.

Authors:  K-H Widmer; B Zurfluh
Journal:  J Orthop Res       Date:  2004-07       Impact factor: 3.494

4.  Acetabular cup migration. Prediction of aseptic loosening.

Authors:  G W Stocks; M A Freeman; S J Evans
Journal:  J Bone Joint Surg Br       Date:  1995-11

5.  Joint motion and surface contact area related to component position in total hip arthroplasty.

Authors:  R P Robinson; P T Simonian; I M Gradisar; R P Ching
Journal:  J Bone Joint Surg Br       Date:  1997-01

6.  Prediction of clinical outcome of THR from migration measurements on standard radiographs. A study of cemented Charnley and Stanmore femoral stems.

Authors:  P S Walker; S F Mai; A G Cobb; G Bentley; J Hua
Journal:  J Bone Joint Surg Br       Date:  1995-09

7.  The definition and measurement of acetabular orientation.

Authors:  D W Murray
Journal:  J Bone Joint Surg Br       Date:  1993-03

8.  Dislocations after total hip-replacement arthroplasties.

Authors:  G E Lewinnek; J L Lewis; R Tarr; C L Compere; J R Zimmerman
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

9.  Computed tomography measurement of acetabular cup anteversion and retroversion in total hip arthroplasty.

Authors:  S W Mian; G Truchly; F A Pflum
Journal:  Clin Orthop Relat Res       Date:  1992-03       Impact factor: 4.176

10.  Analysis of optimal range of socket orientations in total hip arthroplasty with use of computer-aided design simulation.

Authors:  M Seki; N Yuasa; K Ohkuni
Journal:  J Orthop Res       Date:  1998-07       Impact factor: 3.494

View more
  6 in total

1.  Combining femoral and acetabular parameters in femoroacetabular impingement: the omega surface.

Authors:  Heinse Bouma; Tom Hogervorst; Emanuel Audenaert; Paulien van Kampen
Journal:  Med Biol Eng Comput       Date:  2015-10-07       Impact factor: 2.602

2.  Bony impingement limits design-related increases in hip range of motion.

Authors:  Adam Bunn; Clifford W Colwell; Darryl D D'Lima
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

3.  Finite element model of the impaction of a press-fitted acetabular cup.

Authors:  Adrien Michel; Vu-Hieu Nguyen; Romain Bosc; Romain Vayron; Philippe Hernigou; Salah Naili; Guillaume Haiat
Journal:  Med Biol Eng Comput       Date:  2016-08-04       Impact factor: 2.602

4.  Effect of femoral neck modularity upon the prosthetic range of motion in total hip arthroplasty.

Authors:  Glen A Turley; Damian R Griffin; Mark A Williams
Journal:  Med Biol Eng Comput       Date:  2014-06-27       Impact factor: 2.602

5.  Evaluation of range of motion restriction within the hip joint.

Authors:  Glen A Turley; Mark A Williams; Richard M Wellings; Damian R Griffin
Journal:  Med Biol Eng Comput       Date:  2012-12-22       Impact factor: 2.602

6.  Range of Movement for Impingement and Dislocation Avoidance in Total Hip Replacement Predicted by Finite Element Model.

Authors:  Laura Ezquerra; María Paz Quilez; María Ángeles Pérez; Jorge Albareda; Belén Seral
Journal:  J Med Biol Eng       Date:  2017-01-21       Impact factor: 1.553

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.