Literature DB >> 7593094

Acetabular cup migration. Prediction of aseptic loosening.

G W Stocks1, M A Freeman, S J Evans.   

Abstract

We measured the proximal migration of 265 acetabular cups over seven years and correlated the findings with clinical outcome and acetabular revision for aseptic loosening. Cups which eventually became aseptically loose were shown to migrate more rapidly than successful cups. The average proximal migration at two years postoperatively for four groups of cups showed a monotonic relationship to the acetabular revision rate for aseptic loosening at 6.5 years. We conclude that acetabular cups which develop aseptic loosening as evidenced by pain, revision or screw fracture show increased proximal migration by one year, and that the 'migration rate' at two years can be used to predict the acetabular revision rate from aseptic loosening at 6.5 years.

Entities:  

Mesh:

Year:  1995        PMID: 7593094

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  19 in total

1.  Radiographic evaluation of the Duraloc cup after 4 years.

Authors:  B Stoeckl; E Brabec; S Wanner; M Krismer; R Biedermann
Journal:  Int Orthop       Date:  2004-10-14       Impact factor: 3.075

Review 2.  [The use of bisphosphonates in arthroplasty].

Authors:  C Eberhardt; B Habermann; A A Kurth
Journal:  Orthopade       Date:  2007-02       Impact factor: 1.087

3.  Range of motion measurement of an artificial hip joint using CT images.

Authors:  Haosheng Sun; Hidenori Inaoka; Yutaka Fukuoka; Tadashi Masuda; Akimasa Ishida; Sadao Morita
Journal:  Med Biol Eng Comput       Date:  2007-09-26       Impact factor: 2.602

4.  Migration of the Duraloc cup after 5 years.

Authors:  Christoph Stihsen; Christof Pabinger; Roman Radl; Peter Rehak; Reinhard Windhager
Journal:  Int Orthop       Date:  2007-07-03       Impact factor: 3.075

5.  Early aseptic loosening of cementless monoblock acetabular components.

Authors:  Simo S A Miettinen; Tatu J Mäkinen; Inari Laaksonen; Keijo Mäkelä; Heini Huhtala; Jukka Kettunen; Ville Remes
Journal:  Int Orthop       Date:  2016-08-10       Impact factor: 3.075

6.  Pose estimation of artificial hip joint using a single radiographic projection.

Authors:  H Inaoka; A Ishidal; Y Fukuoka; K Suzuki; M Matsubara
Journal:  Med Biol Eng Comput       Date:  2003-01       Impact factor: 2.602

7.  Results of the cementless Plasmacup in revision total hip arthroplasty: a retrospective study of 72 cases with an average follow-up of eight years.

Authors:  Stefan Lakemeier; Guenter Aurand; Nina Timmesfeld; Thomas J Heyse; Susanne Fuchs-Winkelmann; Markus D Schofer
Journal:  BMC Musculoskelet Disord       Date:  2010-05-27       Impact factor: 2.362

8.  Fatigue in cemented acetabular replacements.

Authors:  J Tong; N P Zant; J-Y Wang; P Heaton-Adegbile; J G Hussell
Journal:  Int J Fatigue       Date:  2008-08       Impact factor: 5.186

9.  Once-weekly oral medication with alendronate does not prevent migration of knee prostheses: A double-blind randomized RSA study.

Authors:  Ulrik Hansson; Sören Toksvig-Larsen; Leif Ryd; Per Aspenberg
Journal:  Acta Orthop       Date:  2009-02       Impact factor: 3.717

10.  Determination of interfacial fracture toughness of bone-cement interface using sandwich Brazilian disks.

Authors:  J Tong; K Y Wong; C Lupton
Journal:  Eng Fract Mech       Date:  2007-08       Impact factor: 4.406

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.