The effect of acetabular cup orientations on limiting hip rotation.

F J Kummer1, S Shah, S Iyer, P E DiCesare.   

Abstract

The orientation of the acetabular cup and position of lip augmentation (if present) may improve postoperative total hip replacement stability by decreasing dislocation caused by hip prosthesis impingement during rotation. To determine how these cup parameters affect dislocation, the range and amount of rotation for two standard femoral components was determined in a Sawbones hemipelvis model. The parameters that allowed for maximal range of rotation were a cup angle of inclination between 35 degrees and 45 degrees and cup anteversion between 0 degrees and 10 degrees. Cup anteversion angles greater than 20 degrees and cup angles of inclination greater than 45 degrees significantly limited internal and external rotation, particularly for hip flexion greater than 60 degrees. The position of the cup lip augmentation did not affect the amount of rotation except when the hip was flexed and the lip superiorly oriented. Although there are currently devices to facilitate a particular cup position, hip stem type and orientation are other important factors affecting range of rotation that must be considered.

Entities:  

Mesh:

Year:  1999        PMID: 10428235     DOI: 10.1016/s0883-5403(99)90110-9

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  46 in total

1.  Hip-spine relationship: a radio-anatomical study for optimization in acetabular cup positioning.

Authors:  J-Y Lazennec; N Charlot; M Gorin; B Roger; N Arafati; A Bissery; G Saillant
Journal:  Surg Radiol Anat       Date:  2003-11-07       Impact factor: 1.246

2.  [CT-free image guided acetabulum navigation in clinical routine].

Authors:  J Von Recum; K Wendl; J Korber; A Wentzensen; P A Grützner
Journal:  Unfallchirurg       Date:  2003-11       Impact factor: 1.000

3.  Differences between the wear couples metal-on-polyethylene and ceramic-on-ceramic in the stability against dislocation of total hip replacement.

Authors:  Rainer Bader; Erwin Steinhauser; Susanne Zimmermann; Wolfram Mittelmeier; Roger Scholz; Raymonde Busch
Journal:  J Mater Sci Mater Med       Date:  2004-06       Impact factor: 3.896

4.  A new method of measuring acetabular cup anteversion on simulated radiographs.

Authors:  Vikas Bachhal; Nipun Jindal; Gaurav Saini; Radheshyam Sament; Vishal Kumar; Devendra Chouhan; Mandeep Dhillon
Journal:  Int Orthop       Date:  2012-05-31       Impact factor: 3.075

5.  Accuracy and reliability of different methods to evaluate the acetabular cup version from plain radiographs.

Authors:  Maximilian Haenle; Wolfram Mittelmeier; Rodrigo Barbano; Klaus Wörtler; Roger Scholz; Rainer Bader
Journal:  Surg Radiol Anat       Date:  2010-06-25       Impact factor: 1.246

6.  A critical analysis of radiographic factors in patients who develop dislocation after elective primary total hip arthroplasty.

Authors:  Marion Opperer; Yuo-yu Lee; Francisco Nally; Alvaro Blanes Perez; Kaveh Goudarz-Mehdikhani; Alejandro Gonzalez Della Valle
Journal:  Int Orthop       Date:  2015-10-27       Impact factor: 3.075

7.  Comparison of robotic-assisted and conventional acetabular cup placement in THA: a matched-pair controlled study.

Authors:  Benjamin G Domb; Youssef F El Bitar; Adam Y Sadik; Christine E Stake; Itamar B Botser
Journal:  Clin Orthop Relat Res       Date:  2013-08-29       Impact factor: 4.176

8.  [Comparison of total hip replacements cup orientation and position. Navigation vs. conventional manual implantation of hip prostheses].

Authors:  M Honl; K Schwieger; C H Gauck; F Lampe; M M Morlock; M A Wimmer; E Hille
Journal:  Orthopade       Date:  2005-11       Impact factor: 1.087

9.  Greater accuracy in positioning of the acetabular cup by using an image-free navigation system.

Authors:  T Kalteis; M Handel; T Herold; L Perlick; H Baethis; J Grifka
Journal:  Int Orthop       Date:  2005-08-05       Impact factor: 3.075

10.  Assessment of cup position from plain radiographs: impact of pelvic tilting.

Authors:  M Haenle; A Heitner; W Mittelmeier; R Barbano; R Scholz; E Steinhauser; R Bader
Journal:  Surg Radiol Anat       Date:  2007-01-10       Impact factor: 1.246

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.