Prediction of clinical outcome of THR from migration measurements on standard radiographs. A study of cemented Charnley and Stanmore femoral stems.

P S Walker1, S F Mai, A G Cobb, G Bentley, J Hua.   

Abstract

We report the theoretical basis of a method to measure axial migration of femoral components of total hip replacements (THR). The use of the top of the greater trochanter and a lateral point on the collar of the stem, allowing for variations of up to 10 degrees rotation of the femur in any direction between successive radiographs, gave a maximum error of 0.37 mm. At a more realistic 5 degrees rotational variation, the error was only 0.13 mm. These data were confirmed in an experimental study using digitisation of points and special software. We also showed that the centre of the femoral head, the stem tip, and the lesser trochanter provided less accurate landmarks. In a second study we digitised a series of radiographs of 51 Charnley and 57 Stanmore THRs; the mean migration rates were found to be identical. We then studied 46 successful stems with a minimum follow-up of eight years and 46 stems which had failed by aseptic loosening at different times. At two years, the successful stems had migrated by a mean of 1.45 +/- 0.68 mm, but the failed cases had a mean migration of 4.32 +/- 2.58 mm (p < 0.0001). Of the successful cases 76% had migrated less than 2 mm, while in the failed group 84% had migrated more than 2 mm. For any particular case migration of more than 2.6 mm at two years had only a 5% chance of continuing success and would therefore merit special follow-up. Only 24% of the eventually successful stems showed migration at the stem-cement interface, but this had happened in every failed stem. We conclude that it would be possible to evaluate a new cemented design of femoral stem over a two-year period by the use of our method and to compare its performance against the reported known standard of the Charnley and Stanmore designs.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7559694

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  28 in total

1.  How long should patients be followed-up after total hip replacement? Current practice in the UK.

Authors:  M J Bankes; R Coull; B D Ferris
Journal:  Ann R Coll Surg Engl       Date:  1999-09       Impact factor: 1.891

2.  Preservation of femoral bone mass after total hip replacements with a lateral flare stem.

Authors:  Alex Leali; Joseph F Fetto
Journal:  Int Orthop       Date:  2004-06       Impact factor: 3.075

3.  Stem-cement porosity may explain early loosening of cemented femoral hip components: experimental-computational in vitro study.

Authors:  Kenneth A Mann; Leatha A Damron; Mark A Miller; Amos Race; Michael T Clarke; Richard J Cleary
Journal:  J Orthop Res       Date:  2007-03       Impact factor: 3.494

4.  Range of motion measurement of an artificial hip joint using CT images.

Authors:  Haosheng Sun; Hidenori Inaoka; Yutaka Fukuoka; Tadashi Masuda; Akimasa Ishida; Sadao Morita
Journal:  Med Biol Eng Comput       Date:  2007-09-26       Impact factor: 2.602

5.  Promising mid-term results of total hip arthroplasties using an uncemented lateral-flare hip prosthesis: a clinical and radiographic study.

Authors:  Alex Leali; Joseph Fetto
Journal:  Int Orthop       Date:  2007-02-14       Impact factor: 3.075

6.  Aseptic stem loosening in primary THA: migration analysis of cemented and cementless fixation.

Authors:  Artur Kroell; Paul Beaulé; Martin Krismer; Hannes Behensky; Bernd Stoeckl; Rainer Biedermann
Journal:  Int Orthop       Date:  2008-12-06       Impact factor: 3.075

7.  Joint responsibility: the need for a national arthroplasty register.

Authors:  D H Sochart; A J Long; M L Porter
Journal:  BMJ       Date:  1996-07-13

Review 8.  Model-based interpretation of complex and variable images.

Authors:  C J Taylor; T F Cootes; A Lanitis; G Edwards; P Smyth; A C Kotcheff
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  1997-08-29       Impact factor: 6.237

9.  Pose estimation of artificial hip joint using a single radiographic projection.

Authors:  H Inaoka; A Ishidal; Y Fukuoka; K Suzuki; M Matsubara
Journal:  Med Biol Eng Comput       Date:  2003-01       Impact factor: 2.602

10.  A prospective study of hip revision surgery using the Exeter long-stem prosthesis: function, subsidence, and complications for 57 patients.

Authors:  K Randhawa; F S Hossain; B Smith; Cyril Mauffrey; T Lawrence
Journal:  J Orthop Traumatol       Date:  2009-10-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.