Literature DB >> 21918798

Bony impingement limits design-related increases in hip range of motion.

Adam Bunn1, Clifford W Colwell, Darryl D D'Lima.   

Abstract

BACKGROUND: Factors affecting risk for impingement and dislocation can be related to the patient, implant design, or surgeon. While these have been studied independently, the impact of each factor relative to the others is not known. QUESTIONS/PURPOSES: We determined the effect of three implant design factors, prosthetic placement, and patient anatomy on subject-specific ROM.
METHODS: We virtually implanted hip geometry obtained from 16 CT scans using computer models of hip components with differences in head size, neck diameter, and neck-shaft angle. A contact detection model computed ROM before prosthetic or bony impingement. We correlated anatomic measurements from pelvic radiographs with ROM.
RESULTS: When we implanted the components for best fit to the subject's anatomy or in the recommended orientation of 45° abduction and 20° anteversion, ROM was greater than 110° of flexion, 30° of extension, 45° of adduction-abduction, and 40° of external rotation. Changes in head size, neck diameter, and neck-shaft angle generated small gains (3.6°-6°) in ROM when analyzed individually, but collectively, we noted a more substantial increase (10°-17°). Radiographic measurements correlated only moderately with hip flexion and abduction.
CONCLUSIONS: It is feasible to tailor implant placement to each patient to maximize bony coverage without compromising ROM. Once bony impingement becomes the restricting factor, further changes in implant design may not improve ROM. Radiographic measurements do not appear to have value in predicting ROM.

Entities:  

Mesh:

Year:  2012        PMID: 21918798      PMCID: PMC3254736          DOI: 10.1007/s11999-011-2096-3

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  49 in total

1.  Kinematics, kinetics, and finite element analysis of commonplace maneuvers at risk for total hip dislocation.

Authors:  Mark E Nadzadi; Douglas R Pedersen; H John Yack; John J Callaghan; Thomas D Brown
Journal:  J Biomech       Date:  2003-04       Impact factor: 2.712

Review 2.  Instability after total hip arthroplasty.

Authors:  B F Morrey
Journal:  Orthop Clin North Am       Date:  1992-04       Impact factor: 2.472

3.  Three-dimensional planning and virtual radiographs in revision total hip arthroplasty for instability.

Authors:  Michael J Seel; Mahmoud A Hafez; Kort Eckman; Branislav Jaramaz; David Davidson; Anthony M DiGioia
Journal:  Clin Orthop Relat Res       Date:  2006-01       Impact factor: 4.176

4.  Range of motion measurement of an artificial hip joint using CT images.

Authors:  Haosheng Sun; Hidenori Inaoka; Yutaka Fukuoka; Tadashi Masuda; Akimasa Ishida; Sadao Morita
Journal:  Med Biol Eng Comput       Date:  2007-09-26       Impact factor: 2.602

5.  Computer-assisted versus manual alignment in THA: a probabilistic approach to range of motion.

Authors:  Anthony J Petrella; Joshua Q Stowe; Darryl D D'Lima; Paul J Rullkoetter; Peter J Laz
Journal:  Clin Orthop Relat Res       Date:  2008-10-22       Impact factor: 4.176

6.  Correlation of measured range of hip motion following total hip arthroplasty and responses to a questionnaire.

Authors:  B J McGrory; A A Freiberg; A A Shinar; W H Harris
Journal:  J Arthroplasty       Date:  1996-08       Impact factor: 4.757

7.  Postoperative total hip prosthetic femoral head dislocations. Incidence, etiologic factors, and management.

Authors:  R S Turner
Journal:  Clin Orthop Relat Res       Date:  1994-04       Impact factor: 4.176

8.  Constrained liner in neurologic or cognitively impaired patients undergoing primary THA.

Authors:  Philippe Hernigou; Paolo Filippini; Charles-Henri Flouzat-Lachaniette; Sobrinho Uirassu Batista; Alexandre Poignard
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

9.  Influence of total hip design on dislocation: a computer model and clinical analysis.

Authors:  Douglas E Padgett; Joseph Lipman; Bruce Robie; Bryan J Nestor
Journal:  Clin Orthop Relat Res       Date:  2006-06       Impact factor: 4.176

10.  Outcomes of total hip arthroplasty: a study of patients one year postsurgery.

Authors:  Elaine Trudelle-Jackson; Roger Emerson; Sue Smith
Journal:  J Orthop Sports Phys Ther       Date:  2002-06       Impact factor: 4.751

View more
  7 in total

1.  Effects of ball head diameter and stem neck shape in range of motion after total hip arthroplasty: A simulation study.

Authors:  Tsutomu Higashi; Nobuhiro Kaku; Shouhei Noda; Tomonori Tabata; Hiroaki Tagomori; Hiroshi Tsumura
Journal:  J Orthop       Date:  2019-09-11

2.  Anteroinferior acetabular rim damage due to femoroacetabular impingement.

Authors:  Lisa M Tibor; Reinhold Ganz; Michael Leunig
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

3.  Posterior Extra-articular Ischiofemoral Impingement Can Be Caused by the Lesser and Greater Trochanter in Patients With Increased Femoral Version: Dynamic 3D CT-Based Hip Impingement Simulation of a Modified FABER Test.

Authors:  Till D Lerch; Sébastien Zwingelstein; Florian Schmaranzer; Adam Boschung; Markus S Hanke; Inga A S Todorski; Simon D Steppacher; Nicolas Gerber; Guodong Zeng; Klaus A Siebenrock; Moritz Tannast
Journal:  Orthop J Sports Med       Date:  2021-05-28

4.  Dissociation of modular total hip arthroplasty at the neck-stem interface without dislocation.

Authors:  A Kouzelis; C S Georgiou; P Megas
Journal:  J Orthop Traumatol       Date:  2011-12-08

5.  Combined abnormalities of femoral version and acetabular version and McKibbin Index in FAI patients evaluated for hip preservation surgery.

Authors:  Till D Lerch; Tiziano Antioco; Malin K Meier; Adam Boschung; Markus S Hanke; Moritz Tannast; Klaus A Siebenrock; Florian Schmaranzer; Simon D Steppacher
Journal:  J Hip Preserv Surg       Date:  2022-04-21

6.  No functional benefit of larger femoral heads and alternative bearings at 6 months following primary hip replacement.

Authors:  Simon S Jameson; James M Mason; Paul N Baker; Paul J Gregg; David J Deehan; Mike R Reed
Journal:  Acta Orthop       Date:  2014-10-10       Impact factor: 3.717

7.  Late Onset Disassembly of a Modular Neck-stem Component after Cementless Hip Replacement without Dislocation: A Case Report and Review of Literatures.

Authors:  Ioannis Papaioannou; Thomas Repantis; Andreas Baikousis; Panagiotis Korovessis
Journal:  Hip Pelvis       Date:  2018-09-04
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.