Literature DB >> 9020463

Joint motion and surface contact area related to component position in total hip arthroplasty.

R P Robinson1, P T Simonian, I M Gradisar, R P Ching.   

Abstract

A three-dimensional computer model of a total hip replacement was used to examine the relationship between the position of the components, the range of motion and the prosthetic joint contact area. Horizontal acetabular positions with small amounts of acetabular and femoral anteversion provide the largest contact areas, but result in limited joint movement. These data will allow surgeons to select implant positions that will provide the largest possible joint contact area for a given joint range of motion although these are conflicting goals. In some component positions a truncated spherical prosthetic head resulted in smaller contact areas than a completely spherical head.

Entities:  

Mesh:

Year:  1997        PMID: 9020463     DOI: 10.1302/0301-620x.79b1.6842

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  15 in total

1.  A new method of measuring acetabular cup anteversion on simulated radiographs.

Authors:  Vikas Bachhal; Nipun Jindal; Gaurav Saini; Radheshyam Sament; Vishal Kumar; Devendra Chouhan; Mandeep Dhillon
Journal:  Int Orthop       Date:  2012-05-31       Impact factor: 3.075

2.  Development of imageless computer navigation for acetabular component position in total hip replacement.

Authors:  Lawrence D Dorr; Yuji Hishiki; Zhinian Wan; Deanne Newton; Andrew Yun
Journal:  Iowa Orthop J       Date:  2005

3.  Range of motion measurement of an artificial hip joint using CT images.

Authors:  Haosheng Sun; Hidenori Inaoka; Yutaka Fukuoka; Tadashi Masuda; Akimasa Ishida; Sadao Morita
Journal:  Med Biol Eng Comput       Date:  2007-09-26       Impact factor: 2.602

4.  Using acetabular fossa as a guide for anticipated inclination of uncemented cup in total hip replacement.

Authors:  Junwei Li; Xu Gao; Guanghui Yang; Yanru Zhang
Journal:  Int J Clin Exp Med       Date:  2015-01-15

5.  [Comparative study of intra- and post-operative inclination and anteversion angles of acetabular cup in robot-assisted total hip arthroplasty].

Authors:  Run Tian; Yutian Lei; Kunzheng Wang; Pei Yang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-10-15

6.  Impingement in Total Hip Replacement: Mechanisms and Consequences.

Authors:  Thomas D Brown; John J Callaghan
Journal:  Curr Orthop       Date:  2008-12-01

7.  Pose estimation of artificial hip joint using a single radiographic projection.

Authors:  H Inaoka; A Ishidal; Y Fukuoka; K Suzuki; M Matsubara
Journal:  Med Biol Eng Comput       Date:  2003-01       Impact factor: 2.602

8.  Acetabular polyethylene wear and acetabular inclination and femoral offset.

Authors:  Nick J Little; Constant A Busch; John A Gallagher; Cecil H Rorabeck; Robert B Bourne
Journal:  Clin Orthop Relat Res       Date:  2009-05-02       Impact factor: 4.176

9.  GeoGebra: A reliable and free software for measuring acetabular cup anteversion on digitalized plain radiographs.

Authors:  Vikas Bachhal; Gaurav Saini; Nipun Jindal; Radheshyam Sament; Ankit Dadra
Journal:  J Clin Orthop Trauma       Date:  2020-02-05

10.  Long-term Results of Primary Hip Arthroplasty with Cup Inclination Angle Bigger than Fifty Degrees.

Authors:  Jialiang Tian; Li Sun; Ruiyin Hu; Wei Han; Xiaobin Tian
Journal:  J Clin Orthop Trauma       Date:  2017-04-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.