Literature DB >> 7808262

The effect of high performance gradients on fast gradient echo imaging.

S B Reeder1, E R McVeigh.   

Abstract

The effect of gradient system performance on segmented k-space gradient echo imaging is presented. Three cases were investigated. First, an ideal system that has infinite slew rates and unlimited maximum gradient strengths was considered. Second, a "high speed" imaging system (2.3 (G/cm), 23 (G/cm)/ms) was considered. These two cases were compared with a "conventional" imaging system (1(G/cm), 1.67 (G/cm)/ms). It was found that substantial increases in SNR can be achieved (approximately 45%) by using high speed versus a conventional gradient system, for a TR of 6 ms. For trapezoidal gradient waveforms, there exists an optimum maximum gradient strength for a given slew rate, and any increase in gradient strength above this optimum will not be utilized by an optimized sequence. These studies have shown that increasing TR without decreasing the bandwidth is not a good way to increase SNR for constant scan time.

Mesh:

Year:  1994        PMID: 7808262      PMCID: PMC2396302          DOI: 10.1002/mrm.1910320510

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  14 in total

1.  Magnetic resonance imaging of myocardial kinematics. Technique to detect, localize, and quantify the strain rates of the active human myocardium.

Authors:  V J Wedeen
Journal:  Magn Reson Med       Date:  1992-09       Impact factor: 4.668

2.  Projection reconstruction techniques for reduction of motion effects in MRI.

Authors:  G H Glover; J M Pauly
Journal:  Magn Reson Med       Date:  1992-12       Impact factor: 4.668

3.  Fast spiral coronary artery imaging.

Authors:  C H Meyer; B S Hu; D G Nishimura; A Macovski
Journal:  Magn Reson Med       Date:  1992-12       Impact factor: 4.668

4.  Cardiac tagging with breath-hold cine MRI.

Authors:  E R McVeigh; E Atalar
Journal:  Magn Reson Med       Date:  1992-12       Impact factor: 4.668

5.  Spoiling of transverse magnetization in steady-state sequences.

Authors:  Y Zur; M L Wood; L J Neuringer
Journal:  Magn Reson Med       Date:  1991-10       Impact factor: 4.668

6.  A spoiling sequence for suppression of residual transverse magnetization.

Authors:  H Z Wang; S J Riederer
Journal:  Magn Reson Med       Date:  1990-08       Impact factor: 4.668

7.  Cineangiography of the heart in a single breath hold with a segmented turboFLASH sequence.

Authors:  D J Atkinson; R R Edelman
Journal:  Radiology       Date:  1991-02       Impact factor: 11.105

8.  The intrinsic signal-to-noise ratio in NMR imaging.

Authors:  W A Edelstein; G H Glover; C J Hardy; R W Redington
Journal:  Magn Reson Med       Date:  1986-08       Impact factor: 4.668

9.  Echo-planar MR imaging of normal and ischemic myocardium with gadodiamide injection.

Authors:  M F Wendland; M Saeed; T Masui; N Derugin; M E Moseley; C B Higgins
Journal:  Radiology       Date:  1993-02       Impact factor: 11.105

10.  Echo-planar imaging of the liver with a standard MR imaging system.

Authors:  K Butts; S J Riederer; R L Ehman; J P Felmlee; R C Grimm
Journal:  Radiology       Date:  1993-10       Impact factor: 11.105

View more
  11 in total

1.  A new approach to measure single-event related brain activity using real-time fMRI: feasibility of sensory, motor, and higher cognitive tasks.

Authors:  S Posse; F Binkofski; F Schneider; D Gembris; W Frings; U Habel; J B Salloum; K Mathiak; S Wiese; V Kiselev; T Graf; B Elghahwagi; M L Grosse-Ruyken; T Eickermann
Journal:  Hum Brain Mapp       Date:  2001-01       Impact factor: 5.038

2.  Multi-echo segmented k-space imaging: an optimized hybrid sequence for ultrafast cardiac imaging.

Authors:  S B Reeder; E Atalar; A Z Faranesh; E R McVeigh
Journal:  Magn Reson Med       Date:  1999-02       Impact factor: 4.668

3.  Multishot EPI-SSFP in the heart.

Authors:  Daniel A Herzka; Peter Kellman; Anthony H Aletras; Michael A Guttman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2002-04       Impact factor: 4.668

4.  Extended coverage first-pass perfusion imaging using slice-interleaved TSENSE.

Authors:  P Kellman; J A Derbyshire; K O Agyeman; E R McVeigh; A E Arai
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

5.  Signal-to-noise ratio behavior of steady-state free precession.

Authors:  Scott B Reeder; Daniel A Herzka; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2004-07       Impact factor: 4.668

6.  Quantification and reduction of ghosting artifacts in interleaved echo-planar imaging.

Authors:  S B Reeder; E Atalar; B D Bolster; E R McVeigh
Journal:  Magn Reson Med       Date:  1997-09       Impact factor: 4.668

7.  Multi-shot EPI for improvement of myocardial tag contrast: comparison with segmented SPGR.

Authors:  C Tang; E R McVeigh; E A Zerhouni
Journal:  Magn Reson Med       Date:  1995-03       Impact factor: 4.668

8.  Minimization of dead-periods in MRI pulse sequences for imaging oblique planes.

Authors:  E Atalar; E R McVeigh
Journal:  Magn Reson Med       Date:  1994-12       Impact factor: 4.668

9.  Quantitative 3D myocardial perfusion with an efficient arterial input function.

Authors:  Jason Kraig Mendes; Ganesh Adluru; Devavrat Likhite; Merlin J Fair; Peter D Gatehouse; Ye Tian; Apoorva Pedgaonkar; Brent Wilson; Edward V R DiBella
Journal:  Magn Reson Med       Date:  2019-10-31       Impact factor: 4.668

10.  Efficient spiral in-out and EPI balanced steady-state free precession cine imaging using a high-performance 0.55T MRI.

Authors:  Matthew C Restivo; Rajiv Ramasawmy; W Patricia Bandettini; Daniel A Herzka; Adrienne E Campbell-Washburn
Journal:  Magn Reson Med       Date:  2020-04-14       Impact factor: 3.737

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.