Multishot EPI-SSFP in the heart.

Daniel A Herzka1, Peter Kellman, Anthony H Aletras, Michael A Guttman, Elliot R McVeigh.   

Abstract

Refocused steady-state free precession (SSFP), or fast imaging with steady precession (FISP or TrueFISP), has recently proven valuable for cardiac imaging because of its high signal-to-noise ratio (SNR) and excellent blood-myocardium contrast. In this study, various implementations of multiecho SSFP or EPI-SSFP for imaging in the heart are presented. EPI-SSFP has higher scan-time efficiency than single-echo SSFP, as two or more phase-encode lines are acquired per repetition time (TR) at the cost of a modest increase in TR. To minimize TR, a noninterleaved phase-encode order in conjunction with a phased-array ghost elimination (PAGE) technique was employed, removing the need for echo time shifting (ETS). The multishot implementation of EPI-SSFP was used to decrease the breath-hold duration for cine acquisitions or to increase the temporal or spatial resolution for a fixed breath-hold duration. The greatest gain in efficiency was obtained with the use of a three-echo acquisition. Image quality for cardiac cine applications using multishot EPI-SSFP was comparable to that of single-echo SSFP in terms of blood-myocardium contrast and contrast-to-noise ratio (CNR). The PAGE method considerably reduced flow artifacts due to both the inherent ghost suppression and the concomitant reduction in phase-encode blip size. The increased TR of multishot EPI-SSFP led to a reduced specific absorption rate (SAR) for a fixed RF flip angle, and allowed the use of a larger flip angle without increasing the SAR above the FDA-approved limits. Copyright 2002 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2002        PMID: 11948726      PMCID: PMC2396260          DOI: 10.1002/mrm.10105

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  27 in total

1.  Ghost artifact cancellation using phased array processing.

Authors:  P Kellman; E R McVeigh
Journal:  Magn Reson Med       Date:  2001-08       Impact factor: 4.668

2.  Segmented k-space fast cardiac imaging using an echo-train readout.

Authors:  F H Epstein; S D Wolff; A E Arai
Journal:  Magn Reson Med       Date:  1999-03       Impact factor: 4.668

3.  Analysis of the higher-order echoes in SSFP.

Authors:  D J Kim; Z H Cho
Journal:  Magn Reson Med       Date:  1991-05       Impact factor: 4.668

4.  Multiple echo SSFP sequences.

Authors:  C T Mizumoto; E Yoshitome
Journal:  Magn Reson Med       Date:  1991-03       Impact factor: 4.668

5.  Analysis of flow effects in echo-planar imaging.

Authors:  K Butts; S J Riederer
Journal:  J Magn Reson Imaging       Date:  1992 May-Jun       Impact factor: 4.813

6.  Theoretical aspects of motion sensitivity and compensation in echo-planar imaging.

Authors:  J L Duerk; O P Simonetti
Journal:  J Magn Reson Imaging       Date:  1991 Nov-Dec       Impact factor: 4.813

7.  Echo-planar imaging with asymmetric gradient modulation and inner-volume excitation.

Authors:  D A Feinberg; R Turner; P D Jakab; M von Kienlin
Journal:  Magn Reson Med       Date:  1990-01       Impact factor: 4.668

8.  The application of steady-state free precession in rapid 2DFT NMR imaging: FAST and CE-FAST sequences.

Authors:  M L Gyngell
Journal:  Magn Reson Imaging       Date:  1988 Jul-Aug       Impact factor: 2.546

9.  Fast SSFP gradient echo sequence for simultaneous acquisitions of FID and echo signals.

Authors:  S Y Lee; Z H Cho
Journal:  Magn Reson Med       Date:  1988-10       Impact factor: 4.668

10.  Phase errors in multi-shot echo planar imaging.

Authors:  D A Feinberg; K Oshio
Journal:  Magn Reson Med       Date:  1994-10       Impact factor: 4.668

View more
  7 in total

1.  Myocardial tagging with SSFP.

Authors:  Daniel A Herzka; Michael A Guttman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

2.  Signal-to-noise ratio behavior of steady-state free precession.

Authors:  Scott B Reeder; Daniel A Herzka; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2004-07       Impact factor: 4.668

Review 3.  The future of real-time cardiac magnetic resonance imaging.

Authors:  Krishna S Nayak; Bob S Hu
Journal:  Curr Cardiol Rep       Date:  2005-01       Impact factor: 2.931

4.  Single heartbeat cardiac tagging for the evaluation of transient phenomena.

Authors:  Daniel A Herzka; J Andrew Derbyshire; Peter Kellman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2005-12       Impact factor: 4.668

Review 5.  Advances in MRI tagging techniques for determining regional myocardial strain.

Authors:  Vinay M Pai; Leon Axel
Journal:  Curr Cardiol Rep       Date:  2006-02       Impact factor: 2.931

6.  Phased array ghost elimination.

Authors:  Peter Kellman; Elliot R McVeigh
Journal:  NMR Biomed       Date:  2006-05       Impact factor: 4.044

7.  Efficient spiral in-out and EPI balanced steady-state free precession cine imaging using a high-performance 0.55T MRI.

Authors:  Matthew C Restivo; Rajiv Ramasawmy; W Patricia Bandettini; Daniel A Herzka; Adrienne E Campbell-Washburn
Journal:  Magn Reson Med       Date:  2020-04-14       Impact factor: 3.737

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.