A spoiling sequence for suppression of residual transverse magnetization.

H Z Wang1, S J Riederer.   

Abstract

We present a spoiler sequence which substantially eliminates residual transverse magnetization in rapid magnetic resonance imaging. Such magnetization is due to the repetition time TR being on the order of or shorter than the transverse relaxation time T2. This sequence was designed using computer simulation methods to model the slice profile and signal. The spoiler pulse is applied in the slice-selecting direction and the magnitude of the gradient spoiler is incremented with each repetition as an arithmetic series. A finite number of different spoiler amplitudes is repeated with a cycle time several times greater than the anticipated T2. Each spoiler is shown to nullify the residual transverse magnetization from the just-measured signal of the experiment as well as that from preceding repetitions. It is shown experimentally that the spoiler pulse can be as short as 2 ms. This is considerably shorter than existing methods using constant spoiling or phase-tagged spoiling. This sequence was used to acquire T1-weighted images free of the central line artifact of FLASH imaging. Furthermore, images formed with the new spoiled technique are shown to have contrast-to-noise comparable if not superior to standard T1-weighted spin-echo images while taking only a fifth of the scan time.

Mesh:

Year:  1990        PMID: 2392045     DOI: 10.1002/mrm.1910150202

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  8 in total

1.  Mapping techniques for aligning sulci across multiple brains.

Authors:  Duygu Tosun; Maryam E Rettmann; Jerry L Prince
Journal:  Med Image Anal       Date:  2004-09       Impact factor: 8.545

2.  Disruption of the Arnt gene in endothelial cells causes hepatic vascular defects and partial embryonic lethality in mice.

Authors:  Sun Hee Yim; Yatrik Shah; Shuhei Tomita; H Douglas Morris; Oksana Gavrilova; Gilles Lambert; Jerrold M Ward; Frank J Gonzalez
Journal:  Hepatology       Date:  2006-09       Impact factor: 17.425

3.  Cortical reconstruction using implicit surface evolution: accuracy and precision analysis.

Authors:  Duygu Tosun; Maryam E Rettmann; Daniel Q Naiman; Susan M Resnick; Michael A Kraut; Jerry L Prince
Journal:  Neuroimage       Date:  2005-11-02       Impact factor: 6.556

4.  Contrast-modified gradient echo imaging using rotary echo preparatory pulses.

Authors:  X P Zhu; P B Chilvers; C E Hutchinson; G A Morris; J M Hawnaur; J E Adams; C J Taylor
Journal:  MAGMA       Date:  1997-09       Impact factor: 2.310

5.  The effect of high performance gradients on fast gradient echo imaging.

Authors:  S B Reeder; E R McVeigh
Journal:  Magn Reson Med       Date:  1994-11       Impact factor: 4.668

6.  Reduction of flow artifacts by using partial saturation in RF-spoiled gradient-echo imaging.

Authors:  Misung Han; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2011-02-11       Impact factor: 4.668

7.  Hexagonal gradient scheme with RF spoiling improves spoiling performance for high-flip-angle fast gradient echo imaging.

Authors:  Aaron T Hess; Matthew D Robson
Journal:  Magn Reson Med       Date:  2016-04-01       Impact factor: 4.668

8.  Optimization of steady-state free precession MRI for lung ventilation imaging with 19 F C3 F8 at 1.5T and 3T.

Authors:  Adam Maunder; Madhwesha Rao; Fraser Robb; Jim M Wild
Journal:  Magn Reson Med       Date:  2018-11-02       Impact factor: 4.668

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.