Literature DB >> 1461126

Projection reconstruction techniques for reduction of motion effects in MRI.

G H Glover1, J M Pauly.   

Abstract

Projection reconstruction (PR) techniques are shown to have intrinsic advantages over spin-warp (2DFT) methods with respect to diminished artifacts from respiratory motion. The benefits result from (1) portrayal of artifacts as radial streaks, with the amplitude smallest near the moving elements; (2) streak deployment perpendicular to the direction of motion of moving elements and often residing outside the anatomic boundaries of the subject; (3) inherent signal averaging of low spatial frequencies from oversampling of central k-space data. In addition, respiratory-ordered view angle (ROVA) acquisition is found to diminish residual streaking significantly by reducing interview inconsistencies. Comparisons of 2DFT and PR acquisitions are made with and without ROVA. Reconstructions from magnitude-only projections are found to have increased streaks from motion-induced phase shifts.

Entities:  

Mesh:

Year:  1992        PMID: 1461126     DOI: 10.1002/mrm.1910280209

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  139 in total

1.  Reduction of artifacts in T2 -weighted PROPELLER in high-field preclinical imaging.

Authors:  Prachi Pandit; Yi Qi; Kevin F King; G Allan Johnson
Journal:  Magn Reson Med       Date:  2010-10-06       Impact factor: 4.668

2.  Undersampled projection reconstruction for active catheter imaging with adaptable temporal resolution and catheter-only views.

Authors:  Dana C Peters; Robert J Lederman; Alexander J Dick; Venkatesh K Raman; Michael A Guttman; J Andrew Derbyshire; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

3.  Comparison of brain MR images at 1.5T using BLADE and rectilinear techniques for patients who move during data acquisition.

Authors:  E Nyberg; G S Sandhu; J Jesberger; K A Blackham; D P Hsu; M A Griswold; J L Sunshine
Journal:  AJNR Am J Neuroradiol       Date:  2011-11-17       Impact factor: 3.825

4.  RT-GROG: parallelized self-calibrating GROG for real-time MRI.

Authors:  Haris Saybasili; J Andrew Derbyshire; Peter Kellman; Mark A Griswold; Cengizhan Ozturk; Robert J Lederman; Nicole Seiberlich
Journal:  Magn Reson Med       Date:  2010-07       Impact factor: 4.668

5.  Assessment of Silent T1-weighted head imaging at 7 T.

Authors:  Mauro Costagli; Mark R Symms; Lorenzo Angeli; Douglas A C Kelley; Laura Biagi; Andrea Farnetani; Catarina Rua; Graziella Donatelli; Gianluigi Tiberi; Michela Tosetti; Mirco Cosottini
Journal:  Eur Radiol       Date:  2015-08-29       Impact factor: 5.315

6.  PC VIPR: a high-speed 3D phase-contrast method for flow quantification and high-resolution angiography.

Authors:  Tianliang Gu; Frank R Korosec; Walter F Block; Sean B Fain; Quill Turk; Darren Lum; Yong Zhou; Thomas M Grist; Victor Haughton; Charles A Mistretta
Journal:  AJNR Am J Neuroradiol       Date:  2005-04       Impact factor: 3.825

7.  Volumetric late gadolinium-enhanced myocardial imaging with retrospective inversion time selection.

Authors:  Steve Kecskemeti; Kevin Johnson; Christopher J François; Mark L Schiebler; Orhan Unal
Journal:  J Magn Reson Imaging       Date:  2013-02-06       Impact factor: 4.813

8.  A comparison of radial keyhole strategies for high spatial and temporal resolution 4D contrast-enhanced MRI in small animal tumor models.

Authors:  Ergys Subashi; Everett J Moding; Gary P Cofer; James R MacFall; David G Kirsch; Yi Qi; G Allan Johnson
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

9.  Reducing contrast contamination in radial turbo-spin-echo acquisitions by combining a narrow-band KWIC filter with parallel imaging.

Authors:  Daniel Neumann; Felix A Breuer; Michael Völker; Tobias Brandt; Mark A Griswold; Peter M Jakob; Martin Blaimer
Journal:  Magn Reson Med       Date:  2014-01-16       Impact factor: 4.668

10.  Improved respiratory self-navigation for 3D radial acquisitions through the use of a pencil-beam 2D-T2 -prep for free-breathing, whole-heart coronary MRA.

Authors:  Andrew J Coristine; Jerome Chaptinel; Giulia Ginami; Gabriele Bonanno; Simone Coppo; Ruud B van Heeswijk; Davide Piccini; Matthias Stuber
Journal:  Magn Reson Med       Date:  2017-05-31       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.