Literature DB >> 1987592

Cineangiography of the heart in a single breath hold with a segmented turboFLASH sequence.

D J Atkinson1, R R Edelman.   

Abstract

Six healthy volunteers and three patients with cardiac anomalies were studied in a comparison of segmented turboFLASH (fast low-angle shot) cine, a method of magnetic resonance imaging that permits an entire series of high-resolution cine images to be obtained in one breath hold, with standard cine. Segmented turboFLASH uses a gradient-echo sequence designed for short imaging times in combination with a segmented data acquisition method. Presaturation pulses were applied to eliminate the blood pool signal; the signal-to-noise ratio was assessed with a phantom. Standard hardware and image reconstruction methods were used. The breath-hold images consistently showed reduced ghosting and blurring from respiration. Because a very short echo time was used, segmented turboFLASH was relatively insensitive to dephasing caused by local field disturbances or flow. The authors conclude that, by reducing imaging times and eliminating respiratory artifact, segmented turboFLASH can be useful for performing cine studies of the heart and great vessels.

Entities:  

Mesh:

Year:  1991        PMID: 1987592     DOI: 10.1148/radiology.178.2.1987592

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  68 in total

1.  MR CAT scan: a modular approach for hybrid imaging.

Authors:  C Hillenbrand; D Hahn; A Haase; P M Jakob
Journal:  MAGMA       Date:  2000-07       Impact factor: 2.310

2.  High temporal resolution phase contrast MRI with multiecho acquisitions.

Authors:  Richard B Thompson; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2002-03       Impact factor: 4.668

3.  A comparison of prospective and retrospective respiratory navigator gating in 3D MR coronary angiography.

Authors:  Y P Du; E R McVeigh; D A Bluemke; H A Silber; T K Foo
Journal:  Int J Cardiovasc Imaging       Date:  2001-08       Impact factor: 2.357

4.  Single breath-hold real-time cine MR imaging: improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm.

Authors:  Bernd J Wintersperger; Konstantin Nikolaou; Olaf Dietrich; Johannes Rieber; Matthias Nittka; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2003-05-29       Impact factor: 5.315

5.  Myocardial tagging with SSFP.

Authors:  Daniel A Herzka; Michael A Guttman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

6.  Cardiac tagging with breath-hold cine MRI.

Authors:  E R McVeigh; E Atalar
Journal:  Magn Reson Med       Date:  1992-12       Impact factor: 4.668

7.  Signal-to-noise ratio behavior of steady-state free precession.

Authors:  Scott B Reeder; Daniel A Herzka; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2004-07       Impact factor: 4.668

8.  Flow-gated phase-contrast MRI using radial acquisitions.

Authors:  Richard B Thompson; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2004-09       Impact factor: 4.668

9.  [Determining global heart function with real time TrueFISP in one respiratory cycle].

Authors:  B J Wintersperger; K Nikolaou; O Mühling; A Huber; O Dietrich; M Nittka; B Kiefer; M F Reiser; S O Schoenberg
Journal:  Radiologe       Date:  2004-02       Impact factor: 0.635

10.  Time-resolved MRI after ingestion of liquids reveals motility changes after laparoscopic sleeve gastrectomy--preliminary results.

Authors:  Tobias Baumann; Simon Kuesters; Jodok Grueneberger; Goran Marjanovic; Lisa Zimmermann; Arnd-Oliver Schaefer; Ulrich Theodor Hopt; Mathias Langer; Wojciech Konrad Karcz
Journal:  Obes Surg       Date:  2011-01       Impact factor: 4.129

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.