Literature DB >> 8396785

Echo-planar imaging of the liver with a standard MR imaging system.

K Butts1, S J Riederer, R L Ehman, J P Felmlee, R C Grimm.   

Abstract

PURPOSE: A multisection, whole-body echo-planar imaging (EPI) sequence was developed to obtain T2-weighted images of the liver in one 18-second breath hold with a standard magnetic resonance (MR) imaging system.
MATERIALS AND METHODS: This capability was achieved by dividing the data acquisition period into eight interleaved segments rather than one or two as implemented previously with EPI systems having high-power gradient subsystems.
RESULTS: The interleaved echo-planar images had excellent depiction of anatomy and no identifiable respiratory artifact. In 26 lesions in 12 patients, the eight-shot echo-planar images (2,000/66 [repetition time msec/echo time msec]) had superior contrast compared with conventional T2-weighted spin-echo (SE) images (2,500/60) by an average factor of 1.22 +/- 0.31 (standard deviation) and an average contrast-to-noise ratio relative to conventional T2-weighted SE images of 0.85 +/- 0.22.
CONCLUSION: With a conventional MR imaging system, breath-hold T2-weighted echo-planar images of the liver are comparable in diagnostic quality to conventional T2-weighted SE images.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8396785     DOI: 10.1148/radiology.189.1.8396785

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  8 in total

1.  Early clinical applications of EPI.

Authors:  B S Worthington
Journal:  MAGMA       Date:  1999-12       Impact factor: 2.310

2.  Referenceless interleaved echo-planar imaging.

Authors:  S B Reeder; E Atalar; A Z Faranesh; E R McVeigh
Journal:  Magn Reson Med       Date:  1999-01       Impact factor: 4.668

Review 3.  Ultra-high-speed MR imaging.

Authors:  C P Davis; G C McKinnon; J F Debatin; G K von Schulthess
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

4.  Breathhold imaging of the upper abdomen using a circular polarized-array coil: comparison with standard body coil imaging.

Authors:  J Gauger; N G Holzknecht; C A Lackerbauer; H Sittek; K E Fiedler; R Petsch; M Reiser
Journal:  MAGMA       Date:  1996-06       Impact factor: 2.310

Review 5.  Topics on quantitative liver magnetic resonance imaging.

Authors:  Yì Xiáng J Wáng; Xiaoqi Wang; Peng Wu; Yajie Wang; Weibo Chen; Huijun Chen; Jianqi Li
Journal:  Quant Imaging Med Surg       Date:  2019-11

6.  The effect of high performance gradients on fast gradient echo imaging.

Authors:  S B Reeder; E R McVeigh
Journal:  Magn Reson Med       Date:  1994-11       Impact factor: 4.668

7.  Diffusion-weighted and T2-weighted MR imaging for colorectal liver metastases detection in a rat model at 7 T: a comparative study using histological examination as reference.

Authors:  Mathilde Wagner; Léon Maggiori; Maxime Ronot; Valérie Paradis; Valérie Vilgrain; Yves Panis; Bernard E Van Beers
Journal:  Eur Radiol       Date:  2013-03-02       Impact factor: 5.315

8.  Diffusion-weighted MR imaging of liver on 3.0-Tesla system: effect of intravenous administration of gadoxetic acid disodium.

Authors:  Ji Soo Choi; Myeong-Jin Kim; Jin-Young Choi; Mi-Suk Park; Joon Seok Lim; Ki Whang Kim
Journal:  Eur Radiol       Date:  2009-11-14       Impact factor: 5.315

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.