A mathematical analysis of ghosting artifacts often seen in interleaved echo-planar images (EPI) is presented. These artifacts result from phase and amplitude discontinuities between lines of k-space in the phase-encoding direction, and timing misregistrations from system filter delays. Phase offsets and time delays are often measured using "reference" scans, to reduce ghosting through postprocessing. From the expressions describing ghosting artifacts, criteria were established for reducing ghosting to acceptable levels. Subsequently, the signal-to-noise ratio (SNR) requirements for estimation of time delays and phase offsets, determined from reference scans, was evaluated to establish the effect of estimation error on artifact reduction for interleaved EPI. Artifacts resulting from these effects can be reduced to very low levels when appropriate reference scan estimation is used. This has important implications for functional MRI (fMRI) and applications involving small changes in signal intensity.

Mesh:

Year:  1997        PMID: 9339445      PMCID: PMC2396297          DOI: 10.1002/mrm.1910380312

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  18 in total

1.  Brain magnetic resonance imaging with contrast dependent on blood oxygenation.

Authors:  S Ogawa; T M Lee; A R Kay; D W Tank
Journal:  Proc Natl Acad Sci U S A       Date:  1990-12       Impact factor: 11.205

2.  Magnetic resonance imaging of perfusion using spin inversion of arterial water.

Authors:  D S Williams; J A Detre; J S Leigh; A P Koretsky
Journal:  Proc Natl Acad Sci U S A       Date:  1992-01-01       Impact factor: 11.205

3.  Optimization of tag thickness for measuring position with magnetic resonance imaging.

Authors:  E Atalar; E R McVeigh
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

4.  Cineangiography of the heart in a single breath hold with a segmented turboFLASH sequence.

Authors:  D J Atkinson; R R Edelman
Journal:  Radiology       Date:  1991-02       Impact factor: 11.105

5.  GRASE (Gradient- and spin-echo) imaging: a novel fast MRI technique.

Authors:  K Oshio; D A Feinberg
Journal:  Magn Reson Med       Date:  1991-08       Impact factor: 4.668

6.  Quantitative cardiac perfusion: a noninvasive spin-labeling method that exploits coronary vessel geometry.

Authors:  S B Reeder; M K Atalay; E R McVeigh; E A Zerhouni; J R Forder
Journal:  Radiology       Date:  1996-07       Impact factor: 11.105

7.  Ultrafast interleaved gradient-echo-planar imaging on a standard scanner.

Authors:  G C McKinnon
Journal:  Magn Reson Med       Date:  1993-11       Impact factor: 4.668

8.  Reduction of phase error ghosting artifacts in thin slice fast spin-echo imaging.

Authors:  X Wan; D L Parker; J N Lee; H R Buswell; G T Gullberg
Journal:  Magn Reson Med       Date:  1995-10       Impact factor: 4.668

9.  Qualitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency.

Authors:  R R Edelman; B Siewert; D G Darby; V Thangaraj; A C Nobre; M M Mesulam; S Warach
Journal:  Radiology       Date:  1994-08       Impact factor: 11.105

10.  Phase errors in multi-shot echo planar imaging.

Authors:  D A Feinberg; K Oshio
Journal:  Magn Reson Med       Date:  1994-10       Impact factor: 4.668

View more
  13 in total

1.  A novel object-independent "balanced" reference scan for echo-planar imaging.

Authors:  S B Reeder; A Z Faranesh; E Atalar; E R McVeigh
Journal:  J Magn Reson Imaging       Date:  1999-06       Impact factor: 4.813

2.  Multi-echo segmented k-space imaging: an optimized hybrid sequence for ultrafast cardiac imaging.

Authors:  S B Reeder; E Atalar; A Z Faranesh; E R McVeigh
Journal:  Magn Reson Med       Date:  1999-02       Impact factor: 4.668

3.  Referenceless interleaved echo-planar imaging.

Authors:  S B Reeder; E Atalar; A Z Faranesh; E R McVeigh
Journal:  Magn Reson Med       Date:  1999-01       Impact factor: 4.668

4.  Ghost artifact cancellation using phased array processing.

Authors:  P Kellman; E R McVeigh
Journal:  Magn Reson Med       Date:  2001-08       Impact factor: 4.668

5.  Single heartbeat cardiac tagging for the evaluation of transient phenomena.

Authors:  Daniel A Herzka; J Andrew Derbyshire; Peter Kellman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2005-12       Impact factor: 4.668

6.  Phased array ghost elimination.

Authors:  Peter Kellman; Elliot R McVeigh
Journal:  NMR Biomed       Date:  2006-05       Impact factor: 4.044

7.  In vivo diffusion tensor imaging of thoracic and cervical rat spinal cord at 7 T.

Authors:  Kishore V Mogatadakala; Ponnada A Narayana
Journal:  Magn Reson Imaging       Date:  2009-06-10       Impact factor: 2.546

8.  Robust diffusion tensor imaging by spatiotemporal encoding: Principles and in vivo demonstrations.

Authors:  Eddy Solomon; Gilad Liberman; Noam Nissan; Lucio Frydman
Journal:  Magn Reson Med       Date:  2016-03-10       Impact factor: 4.668

Review 9.  New acquisition techniques and their prospects for the achievable resolution of fMRI.

Authors:  Saskia Bollmann; Markus Barth
Journal:  Prog Neurobiol       Date:  2020-10-23       Impact factor: 11.685

10.  Ultra-high spatial resolution BOLD fMRI in humans using combined segmented-accelerated VFA-FLEET with a recursive RF pulse design.

Authors:  Avery J L Berman; William A Grissom; Thomas Witzel; Shahin Nasr; Daniel J Park; Kawin Setsompop; Jonathan R Polimeni
Journal:  Magn Reson Med       Date:  2020-07-23       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.