Literature DB >> 15236375

Signal-to-noise ratio behavior of steady-state free precession.

Scott B Reeder1, Daniel A Herzka, Elliot R McVeigh.   

Abstract

Steady-state free precession (SSFP) is a rapid gradient-echo imaging technique that has recently gained popularity and is used in a variety of applications, including cardiac and real-time imaging, because of its high signal and favorable contrast between blood and myocardium. The purpose of this work was to examine the signal-to-noise ratio (SNR) behavior of images acquired with SSFP, and the dependence of SNR on imaging parameters such as TR, bandwidth, and image resolution, and the use of multi-echo sequences. In this work it is shown that the SNR of SSFP sequences is dependent only on pulse sequence efficiency, voxel dimensions, and relaxation parameters (T1 and T2). Notably, SNR is insensitive to bandwidth unless increases in bandwidth significantly decrease efficiency. Finally, we examined the relationship between pulse sequence performance (TR and efficiency) and gradient performance (maximum gradient strength and slew rate) for several imaging scenarios, including multi-echo sequences, to determine the optimum matching of maximum gradient strength and slew rate for gradient hardware designs. For standard modern gradient hardware (40 mT/m and 150 mT/m/ms), we found that the maximum gradient strength is more than adequate for the imaging resolution that is commonly encountered with rapid scouting (3 mm x 4 mm x 10 mm voxel). It is well matched for typical CINE and real-time cardiac imaging applications (1.5 mm x 2 mm x 6 mm voxel), and is inadequate for optimal matching with slew rate for high-resolution applications such as musculoskeletal imaging (0.5 x 0.8 x 3 mm voxel). For the lower-resolution methods, efficiency could be improved with higher slew rates; this provokes interest in designing methods for limiting dB/dt peripherally while achieving high switching rates in the imaging field of view. The use of multi-echo SSFP acquisitions leads to substantial improvements in sequence performance (i.e., increased efficiency and shorter TR).

Entities:  

Mesh:

Year:  2004        PMID: 15236375      PMCID: PMC2396310          DOI: 10.1002/mrm.20126

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  23 in total

1.  Simple linear formulation for magnetostimulation specific to MRI gradient coils.

Authors:  B A Chronik; B K Rutt
Journal:  Magn Reson Med       Date:  2001-05       Impact factor: 4.668

2.  Fluctuating equilibrium MRI.

Authors:  S S Vasanawala; J M Pauly; D G Nishimura
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

Review 3.  Diagnostic tools in hydrocephalus.

Authors:  W G Bradley
Journal:  Neurosurg Clin N Am       Date:  2001-10       Impact factor: 2.509

4.  Magnetization preparation during the steady state: fat-saturated 3D TrueFISP.

Authors:  K Scheffler; O Heid; J Hennig
Journal:  Magn Reson Med       Date:  2001-06       Impact factor: 4.668

5.  Multishot EPI-SSFP in the heart.

Authors:  Daniel A Herzka; Peter Kellman; Anthony H Aletras; Michael A Guttman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2002-04       Impact factor: 4.668

6.  Myocardial tagging with SSFP.

Authors:  Daniel A Herzka; Michael A Guttman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

7.  Segmented k-space fast cardiac imaging using an echo-train readout.

Authors:  F H Epstein; S D Wolff; A E Arai
Journal:  Magn Reson Med       Date:  1999-03       Impact factor: 4.668

8.  Cineangiography of the heart in a single breath hold with a segmented turboFLASH sequence.

Authors:  D J Atkinson; R R Edelman
Journal:  Radiology       Date:  1991-02       Impact factor: 11.105

9.  Using cardiac phase to order reconstruction (CAPTOR): a method to improve diastolic images.

Authors:  J A Feinstein; F H Epstein; A E Arai; T K Foo; M R Hartley; R S Balaban; S D Wolff
Journal:  J Magn Reson Imaging       Date:  1997 Sep-Oct       Impact factor: 4.813

10.  A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1-100 MHz: dependence on tissue type, NMR frequency, temperature, species, excision, and age.

Authors:  P A Bottomley; T H Foster; R E Argersinger; L M Pfeifer
Journal:  Med Phys       Date:  1984 Jul-Aug       Impact factor: 4.071

View more
  7 in total

1.  Dual-Contrast 19F/1H Magnetic Resonance Imaging to Characterize Myocardial Infarct Healing.

Authors:  Gregory M Lanza
Journal:  Circ Cardiovasc Imaging       Date:  2018-11       Impact factor: 7.792

2.  Validation of contrast enhanced cine steady-state free precession and T2-weighted CMR for assessment of ischemic myocardial area-at-risk in the presence of reperfusion injury.

Authors:  Esben Søvsø Szocska Hansen; Steen Fjord Pedersen; Steen Bønløkke Pedersen; Hans Erik Bøtker; Won Yong Kim
Journal:  Int J Cardiovasc Imaging       Date:  2019-03-09       Impact factor: 2.357

Review 3.  Magnetic resonance imaging-guided vascular interventions.

Authors:  Cengizhan Ozturk; Michael Guttman; Elliot R McVeigh; Robert J Lederman
Journal:  Top Magn Reson Imaging       Date:  2005-10

4.  Accuracy of Liver Fat Quantification With Advanced CT, MRI, and Ultrasound Techniques: Prospective Comparison With MR Spectroscopy.

Authors:  Harald Kramer; Perry J Pickhardt; Mark A Kliewer; Diego Hernando; Guang-Hong Chen; James A Zagzebski; Scott B Reeder
Journal:  AJR Am J Roentgenol       Date:  2016-10-11       Impact factor: 3.959

Review 5.  Cardiovascular magnetic resonance at 3.0 T: current state of the art.

Authors:  John N Oshinski; Jana G Delfino; Puneet Sharma; Ahmed M Gharib; Roderic I Pettigrew
Journal:  J Cardiovasc Magn Reson       Date:  2010-10-07       Impact factor: 5.364

6.  Recent Advances in 19Fluorine Magnetic Resonance Imaging with Perfluorocarbon Emulsions.

Authors:  Anne H Schmieder; Shelton D Caruthers; Jochen Keupp; Samuel A Wickline; Gregory M Lanza
Journal:  Engineering (Beijing)       Date:  2016-03-16       Impact factor: 7.553

7.  Optimization of steady-state free precession MRI for lung ventilation imaging with 19 F C3 F8 at 1.5T and 3T.

Authors:  Adam Maunder; Madhwesha Rao; Fraser Robb; Jim M Wild
Journal:  Magn Reson Med       Date:  2018-11-02       Impact factor: 4.668

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.