Literature DB >> 7803352

Optic nerve head analyser and Heidelberg retina tomograph: accuracy and reproducibility of topographic measurements in a model eye and in volunteers.

P Janknecht1, J Funk.   

Abstract

The accuracy and reproducibility of the optic nerve head analyser (ONHA) and the Heidelberg retina tomograph (HRT) were compared and the performance of the HRT in measuring fundus elevations was evaluated. The coefficient of variation of three repeated measurements in a model eye and in volunteers and the relative error in a model eye was calculated. With ONHA measurements the pooled coefficient of variation in volunteers was 9.3% in measuring cup areas and 8.4% in measuring the cup volume. In a model eye the pooled coefficient of variation was 7.6% for the parameter 'cup area' and 9.9% for the parameter 'cup volume'. The pooled relative error in the model eye was 6.6% for the parameter 'cup area' and 5.1% for the parameter 'cup volume'. With HRT measurements in volunteers the pooled coefficient of variation of both the parameters 'volume below contour' and 'volume below surface' was 6.9%. In the model eye the pooled coefficient of variation was 2.4% for the 'volume below contour' and 4.1% for the parameter 'volume below surface'. The pooled relative error in the model eye was 11.3% for the 'volume below contour' and 11% for the 'volume below surface'. The pooled relative error in measuring retinal elevations in the model eye was 3.8%. The coefficient of variation was 3.5%. The accuracies of the HRT and ONHA were similar. However, as the ONHA 'cup volume' is unreliable in patients because of the design of the ONHA whereas the HRT volume parameters are reliable it seems reasonable to assume that the HRT is superior to the ONHA. Only the HRT is capable of quantifying retinal elevations.

Entities:  

Mesh:

Year:  1994        PMID: 7803352      PMCID: PMC504930          DOI: 10.1136/bjo.78.10.760

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  13 in total

1.  Accuracy of topographic measurements in a model eye with the laser tomographic scanner.

Authors:  A W Dreher; R N Weinreb
Journal:  Invest Ophthalmol Vis Sci       Date:  1991-10       Impact factor: 4.799

2.  Reproducibility of topographic measurements of the normal and glaucomatous optic nerve head with the laser tomographic scanner.

Authors:  A W Dreher; P C Tso; R N Weinreb
Journal:  Am J Ophthalmol       Date:  1991-02-15       Impact factor: 5.258

3.  Variability and reproducibility of optic disk topographic measurements with the Rodenstock Optic Nerve Head Analyzer.

Authors:  K I Bishop; E B Werner; T Krupin; D M Kozart; S R Beck; F A Nunan; M B Wax
Journal:  Am J Ophthalmol       Date:  1988-12-15       Impact factor: 5.258

4.  Reproducibility of topographic measurements of the optic nerve head with laser tomographic scanning.

Authors:  F E Kruse; R O Burk; H E Völcker; G Zinser; U Harbarth
Journal:  Ophthalmology       Date:  1989-09       Impact factor: 12.079

5.  Accuracy of topographic measurements with the Optic Nerve Head Analyzer.

Authors:  M B Shields; J S Tiedeman; K N Miller; D Hickingbotham; A R Ollie
Journal:  Am J Ophthalmol       Date:  1989-03-15       Impact factor: 5.258

6.  Reproducibility of optic disc measurements with computerized analysis of stereoscopic video images.

Authors:  J Caprioli; U Klingbeil; M Sears; B Pope
Journal:  Arch Ophthalmol       Date:  1986-07

7.  [Comparison of two laser scanning tomography systems for three-dimensional analysis of the optic papilla].

Authors:  K Rohrschneider; R O Burk; H E Völcker
Journal:  Ophthalmologe       Date:  1993-12       Impact factor: 1.059

8.  Reliability of optic disk topographic measurements recorded with a video-ophthalmograph.

Authors:  F S Mikelberg; G R Douglas; M Schulzer; T N Cornsweet; K Wijsman
Journal:  Am J Ophthalmol       Date:  1984-07-15       Impact factor: 5.258

9.  Effect of repetitive imaging on topographic measurements of the optic nerve head.

Authors:  R N Weinreb; M Lusky; D U Bartsch; D Morsman
Journal:  Arch Ophthalmol       Date:  1993-05

10.  [Improved reproducibility of computer-assisted structural analysis of the optic papilla].

Authors:  J Funk; R Steeb
Journal:  Klin Monbl Augenheilkd       Date:  1991-06       Impact factor: 0.700

View more
  20 in total

1.  Comparison of long-term fluctuations: laser scanning tomography versus automated perimetry.

Authors:  Jens Funk; Heiko Mueller
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-08-29       Impact factor: 3.117

2.  Blood flow per unit retinal nerve fibre tissue volume is lower in the human inferior retina.

Authors:  A Harris; Y Ishii; H S Chung; C P Jonescu-Cuypers; L J McCranor; L Kagemann; H J Garzozi
Journal:  Br J Ophthalmol       Date:  2003-02       Impact factor: 4.638

Review 3.  Imaging in glaucoma.

Authors:  Daniel M Stein; Gadi Wollstein; Joel S Schuman
Journal:  Ophthalmol Clin North Am       Date:  2004-03

4.  Morphological changes in the optic disc after vitrectomy and fluid-air exchange.

Authors:  Hirokazu Ohashi; Yuzo Kasuga; Naruhiko Hata; Shin-Ichi Manabe; Yasuyuki Takashima; Seiki Lee; Ryoji Yamakawa
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2004-02-13       Impact factor: 3.117

5.  Ten-year results: detection of long-term progressive optic disc changes with confocal laser tomography.

Authors:  Heiko Philippin; Anke Unsoeld; Philip Maier; Sebastian Walter; Michael Bach; Jens Funk
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-08-25       Impact factor: 3.117

6.  Interobserver variability in confocal optic nerve analysis (HRT).

Authors:  Manuel M Hermann; David F Garway-Heath; Christian P Jonescu-Cuypers; Reinhard O W Burk; Jost B Jonas; Christian Y Mardin; Jens Funk; Michael Diestelhorst
Journal:  Int Ophthalmol       Date:  2007-02-06       Impact factor: 2.031

7.  Comparison of measurements of neuroretinal rim area between confocal laser scanning tomography and planimetry of photographs.

Authors:  J B Jonas; C Y Mardin; A E Gründler
Journal:  Br J Ophthalmol       Date:  1998-04       Impact factor: 4.638

8.  Objective morphological assessment of macular hole surgery by scanning laser tomography.

Authors:  C Hudson; S J Charles; J G Flanagan; A K Brahma; G S Turner; D McLeod
Journal:  Br J Ophthalmol       Date:  1997-02       Impact factor: 4.638

Review 9.  Test-retest variability in structural parameters measured with glaucoma imaging devices.

Authors:  Makoto Araie
Journal:  Jpn J Ophthalmol       Date:  2012-11-09       Impact factor: 2.447

10.  Reproducibility of volumetric measurements of normal maculae with the Heidelberg retina tomograph.

Authors:  H J Zambarakji; J E Evans; W M Amoaku; S A Vernon
Journal:  Br J Ophthalmol       Date:  1998-08       Impact factor: 4.638

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.