Literature DB >> 6742084

Reliability of optic disk topographic measurements recorded with a video-ophthalmograph.

F S Mikelberg, G R Douglas, M Schulzer, T N Cornsweet, K Wijsman.   

Abstract

The video-ophthalmograph records the topography of the optic disk via simultaneous stereoscopic images which are stored and analyzed with the help of a microcomputer. This information is used to generate the vertical cup-disk ratio, the vertical optic disk diameter, the cup volume, and the neuroretinal rim area. To determine the reliability of the data, we recorded information for one eye of each of five patients ten times to determine the interphotographic error variance. We also analyzed one photograph for each of five patients ten times to determine the intraphotographic variance attributable to repeated analysis of the same photograph. The interphotographic and intraphotographic coefficients of variation were 2% to 18% and 2% to 7% respectively for these measurements.

Entities:  

Mesh:

Year:  1984        PMID: 6742084     DOI: 10.1016/0002-9394(84)90194-6

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  22 in total

1.  Digital analysis of choroidal neovascularisation in consecutive fluorescein angiograms for use in longitudinal clinical trials.

Authors:  C Bellmann; D W Miller; K Mehltretter; F Schütt; J Jorzik; K Unnebrink; F G Holz
Journal:  Br J Ophthalmol       Date:  2003-07       Impact factor: 4.638

2.  Intraocular pressure-related pattern of optic disc cupping in adult glaucoma patients.

Authors:  D H Shin; M K Lee; K S Briggs; C Kim; J H Zeiter; B McCarty
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1992       Impact factor: 3.117

3.  Early detection of glaucoma by longitudinal monitoring of the optic disc structure.

Authors:  J Funk
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1991       Impact factor: 3.117

4.  Reproducibility of pallor measurements with the optic nerve head analyzer.

Authors:  K N Miller; M B Shields; A R Ollie
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1989       Impact factor: 3.117

5.  Intraimage reproducibility of measurements in the macular area using a computerized system.

Authors:  M Iester; B Mochi; S Lai; F Rathschuler; M Rolando; G Ciurlo
Journal:  Int Ophthalmol       Date:  1997       Impact factor: 2.031

6.  Modern concepts of the diagnosis and treatment of chronic open-angle glaucoma.

Authors:  F S Mikelberg
Journal:  Can Fam Physician       Date:  1986-07       Impact factor: 3.275

7.  Reproducibility of topographic measures of the glaucomatous optic nerve head.

Authors:  O Geyer; A Michaeli-Cohen; D M Silver; D Versano; M Neudorfer; R Dzhanov; M Lazar
Journal:  Br J Ophthalmol       Date:  1998-01       Impact factor: 4.638

8.  Reproducibility of computerized pallor measurements obtained with the Rodenstock Disk Analyzer.

Authors:  F S Mikelberg; G R Douglas; S M Drance; M Schulzer; K Wijsman
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1988       Impact factor: 3.117

Review 9.  Test-retest variability in structural parameters measured with glaucoma imaging devices.

Authors:  Makoto Araie
Journal:  Jpn J Ophthalmol       Date:  2012-11-09       Impact factor: 2.447

10.  Quantitative assessment of the optic nerve head with the laser tomographic scanner.

Authors:  R N Weinreb; A W Dreher; J F Bille
Journal:  Int Ophthalmol       Date:  1989-01       Impact factor: 2.031

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.