Literature DB >> 3729773

Reproducibility of optic disc measurements with computerized analysis of stereoscopic video images.

J Caprioli, U Klingbeil, M Sears, B Pope.   

Abstract

Computerized digital image analysis of the optic nerve head was performed using a simultaneous stereoscopic video camera system to provide rapid, quantitative measurements of optic nerve head topography. Determination of the variability of the measurements is required to estimate the magnitude of optic nerve change over time that can be reliably detected. Total variability, operator variability, and interoperator variability were studied. Total variability was assessed by analyzing ten sets of video recordings made in each of seven eyes of seven normal subjects, and in seven eyes of seven patients with glaucoma. The median coefficients of variation for measurements of total variability in glaucoma patients were as follows: vertical disc measurement, 1.4%; horizontal disc measurement, 2.1%; disc area, 1.9%; vertical cup/disc, 3.9%; horizontal cup/disc, 3.3%; disc rim area, 7.5%; and volume, 7.6%. Operator and interoperator variabilities were considerably smaller in magnitude.

Entities:  

Mesh:

Year:  1986        PMID: 3729773     DOI: 10.1001/archopht.1986.01050190093046

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  33 in total

1.  Intraocular pressure-related pattern of optic disc cupping in adult glaucoma patients.

Authors:  D H Shin; M K Lee; K S Briggs; C Kim; J H Zeiter; B McCarty
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1992       Impact factor: 3.117

2.  Early detection of glaucoma by longitudinal monitoring of the optic disc structure.

Authors:  J Funk
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1991       Impact factor: 3.117

3.  Topographic changes in the optic disc in eyes with cotton-wool spots and primary open-angle glaucoma.

Authors:  E Chihara; Y Honda
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1991       Impact factor: 3.117

4.  Reproducibility of pallor measurements with the optic nerve head analyzer.

Authors:  K N Miller; M B Shields; A R Ollie
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1989       Impact factor: 3.117

5.  Correlation between neuroretinal rim area and age in normal subjects.

Authors:  J Funk; T Dieringer; F Grehn
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1989       Impact factor: 3.117

6.  Automated assessment of the optic nerve head on stereo disc photographs.

Authors:  Juan Xu; Hiroshi Ishikawa; Gadi Wollstein; Richard A Bilonick; Kyung R Sung; Larry Kagemann; Kelly A Townsend; Joel S Schuman
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-03-07       Impact factor: 4.799

7.  Detection and quantification of hyperfluorescent leakage by computer analysis of fundus fluorescein angiograms.

Authors:  R P Phillips; P G Ross; M Tyska; P F Sharp; J V Forrester
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1991       Impact factor: 3.117

8.  Optic disc histomorphometry in normal eyes and eyes with secondary angle-closure glaucoma. I. Intrapapillary region.

Authors:  J B Jonas; K A Königsreuther; G O Naumann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1992       Impact factor: 3.117

9.  Optic disc histomorphometry in normal eyes and eyes with secondary angle-closure glaucoma. II. Parapapillary region.

Authors:  J B Jonas; K A Königsreuther; G O Naumann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1992       Impact factor: 3.117

10.  Quantitative evaluation of optic disc pallor in pseudotumor cerebri patients.

Authors:  S Y Lee; D H Shin; T C Spoor; C S Tsai; C Kim; S H Lee
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1992       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.