Literature DB >> 1917403

Accuracy of topographic measurements in a model eye with the laser tomographic scanner.

A W Dreher1, R N Weinreb.   

Abstract

The authors evaluated the accuracy of topographic measurements with the laser tomographic scanner using a model eye. Diameter, depth, and shape at different axial lengths of four sample holes that simulated optic nerve heads in phakic and aphakic conditions were determined by confocal imaging. The computer-generated cross-section profiles of the simulated optic nerve heads corresponded well with the actual contours as photographed by scanning electron microscopy. The average relative error in diameter was 2.0% (range: 0.3-2.9%) for the phakic model eye and 3.6% (range: 0.6-8.2%) for the aphakic model eye. The average relative error in depth was 11.7% (range: 1.2-20.1%) for the phakic model eye and 10.1% (range: 1.7-22.6%) for the aphakic model.

Mesh:

Year:  1991        PMID: 1917403

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  7 in total

1.  Repeatability and reproducibility of optic nerve head topography using the retinal thickness analyzer.

Authors:  Esther M Hoffmann; Felipe A Medeiros; Christina Kramann; Norbert Pfeiffer; Franz H Grus
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-08-05       Impact factor: 3.117

2.  Variability of contour line alignment on sequential images with the Heidelberg Retina Tomograph.

Authors:  S Orgül; G A Croffi; E M Van Buskirk
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1997-02       Impact factor: 3.117

3.  Optic nerve head analyzer and Heidelberg retina tomograph: relative error and reproducibility of topographic measurements in a model eye with simulated cataract.

Authors:  P Janknecht; J Funk
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1995-08       Impact factor: 3.117

4.  Optic nerve head analyser and Heidelberg retina tomograph: accuracy and reproducibility of topographic measurements in a model eye and in volunteers.

Authors:  P Janknecht; J Funk
Journal:  Br J Ophthalmol       Date:  1994-10       Impact factor: 4.638

5.  Detecting AMD with multiply scattered light tomography.

Authors:  A E Elsner; Q Zhou; F Beck; P E Tornambe; S A Burns; J J Weiter; A W Dreher
Journal:  Int Ophthalmol       Date:  2001       Impact factor: 2.031

6.  Assessment of optic disc topography with scanning laser ophthalmoscope.

Authors:  E Chihara; F Takahashi; K Chihara
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1993       Impact factor: 3.117

7.  HRT for the Diagnosis and Detection of Glaucoma Progression.

Authors:  Jessica S Maslin; Kaweh Mansouri; Syril K Dorairaj
Journal:  Open Ophthalmol J       Date:  2015-05-15
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.